90 resultados para EDM


Relevância:

10.00% 10.00%

Publicador:

Resumo:

At head of title page: D.D.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By E.F.A.M. Miel. Cf. Querard. Les supercheries littéraires dévoillées, t. 3, c. 79.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (doctoral)--

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Europeana is the European virtual museum which was established in 2008. Its ambition is to create a common space allowing to access the cultural heritage of Europe from a single portal, by creating a network in all European countries. To make the initiative technically possible, Europeana has built a technological infrastructure to aggregate metadata from the different Europeana countries and memory institutions, while keeping the original digitized content on their sites. This paper presents Bulgariana, the Bulgarian chapter of Europeana. It is part of the technical infrastructure of Europeana, an established technical aggregator of Bulgarian cultural heritage content. It uses the two Europeana representation models ESE and EDM. Bulgariana is also a community building initiative putting in place a Bulgarian wide network of professionals and institutions working together to preserve and present Bulgarian cultural heritage around the world.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Report published in the Proceedings of the National Conference on "Education and Research in the Information Society", Plovdiv, May, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Copyright © 2014 International Anesthesia Research Society.BACKGROUND: Goal-directed fluid therapy (GDFT) is associated with improved outcomes after surgery. The esophageal Doppler monitor (EDM) is widely used, but has several limitations. The NICOM, a completely noninvasive cardiac output monitor (Cheetah Medical), may be appropriate for guiding GDFT. No prospective studies have compared the NICOM and the EDM. We hypothesized that the NICOM is not significantly different from the EDM for monitoring during GDFT. METHODS: One hundred adult patients undergoing elective colorectal surgery participated in this study. Patients in phase I (n = 50) had intraoperative GDFT guided by the EDM while the NICOM was connected, and patients in phase II (n = 50) had intraoperative GDFT guided by the NICOM while the EDM was connected. Each patient's stroke volume was optimized using 250- mL colloid boluses. Agreement between the monitors was assessed, and patient outcomes (postoperative pain, nausea, and return of bowel function), complications (renal, pulmonary, infectious, and wound complications), and length of hospital stay (LOS) were compared. RESULTS: Using a 10% increase in stroke volume after fluid challenge, agreement between monitors was 60% at 5 minutes, 61% at 10 minutes, and 66% at 15 minutes, with no significant systematic disagreement (McNemar P > 0.05) at any time point. The EDM had significantly more missing data than the NICOM. No clinically significant differences were found in total LOS or other outcomes. The mean LOS was 6.56 ± 4.32 days in phase I and 6.07 ± 2.85 days in phase II, and 95% confidence limits for the difference were -0.96 to +1.95 days (P = 0.5016). CONCLUSIONS: The NICOM performs similarly to the EDM in guiding GDFT, with no clinically significant differences in outcomes, and offers increased ease of use as well as fewer missing data points. The NICOM may be a viable alternative monitor to guide GDFT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La utilidad de los Battlegroups, casi una década después de declarar capacidad operativa plena, ha estado y continuará estando en duda debido a la inacción europea. Para que la UE se convierta en el actor internacional que durante tantos años ha proclamado, necesitará consolidar su capacidad de respuesta rápida militar para hacer frente a crisis multidimensionales y llevar a cabo todo el espectro de Misiones Petersberg. El artículo hace un repaso a la concepción y el desarrollo de los Battlegroups y propone un conjunto de reformas para que puedan llegar a ser un instrumento efectivo de respuesta rápida militar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the past, many papers have been presented which show that the coating of cutting tools often yields decreased wear rates and reduced coefficients of friction. Although different theories are proposed, covering areas such as hardness theory, diffusion barrier theory, thermal barrier theory, and reduced friction theory, most have not dealt with the question of how and why the coating of tool substrates with hard materials such as Titanium Nitride (TiN), Titanium Carbide (TiC) and Aluminium Oxide (Al203) transforms the performance and life of cutting tools. This project discusses the complex interrelationship that encompasses the thermal barrier function and the relatively low sliding friction coefficient of TiN on an undulating tool surface, and presents the result of an investigation into the cutting characteristics and performance of EDMed surface-modified carbide cutting tool inserts. The tool inserts were coated with TiN by the physical vapour deposition (PVD) method. PVD coating is also known as Ion-plating which is the general term of the coating method in which the film is created by attracting ionized metal vapour in this the metal was Titanium and ionized gas onto negatively biased substrate surface. Coating by PVD was chosen because it is done at a temperature of not more than 5000C whereas chemical Vapour Deposition CVD process is done at very high temperature of about 8500C and in two stages of heating up the substrates. The high temperatures involved in CVD affects the strength of the (tool) substrates. In this study, comparative cutting tests using TiN-coated control specimens with no EDM surface structures and TiN-coated EDMed tools with a crater-like surface topography were carried out on mild steel grade EN-3. Various cutting speeds were investigated, up to an increase of 40% of the tool manufacturer’s recommended speed. Fifteen minutes of cutting were carried out for each insert at the speeds investigated. Conventional tool inserts normally have a tool life of approximately 15 minutes of cutting. After every five cuts (passes) microscopic pictures of the tool wear profiles were taken, in order to monitor the progressive wear on the rake face and on the flank of the insert. The power load was monitored for each cut taken using an on-board meter on the CNC machine to establish the amount of power needed for each stage of operation. The spindle drive for the machine is an 11 KW/hr motor. Results obtained confirmed the advantages of cutting at all speeds investigated using EDMed coated inserts, in terms of reduced tool wear and low power loads. Moreover, the surface finish on the workpiece was consistently better for the EDMed inserts. The thesis discusses the relevance of the finite element method in the analysis of metal cutting processes, so that metal machinists can design, manufacture and deliver goods (tools) to the market quickly and on time without going through the hassle of trial and error approach for new products. Improvements in manufacturing technologies require better knowledge of modelling metal cutting processes. Technically the use of computational models has a great value in reducing or even eliminating the number of experiments traditionally used for tool design, process selection, machinability evaluation, and chip breakage investigations. In this work, much interest in theoretical and experimental investigations of metal machining were given special attention. Finite element analysis (FEA) was given priority in this study to predict tool wear and coating deformations during machining. Particular attention was devoted to the complicated mechanisms usually associated with metal cutting, such as interfacial friction; heat generated due to friction and severe strain in the cutting region, and high strain rates. It is therefore concluded that Roughened contact surface comprising of peaks and valleys coated with hard materials (TiN) provide wear-resisting properties as the coatings get entrapped in the valleys and help reduce friction at chip-tool interface. The contributions to knowledge: a. Relates to a wear-resisting surface structure for application in contact surfaces and structures in metal cutting and forming tools with ability to give wear-resisting surface profile. b. Provide technique for designing tool with roughened surface comprising of peaks and valleys covered in conformal coating with a material such as TiN, TiC etc which is wear-resisting structure with surface roughness profile compose of valleys which entrap residual coating material during wear thereby enabling the entrapped coating material to give improved wear resistance. c. Provide knowledge for increased tool life through wear resistance, hardness and chemical stability at high temperatures because of reduced friction at the tool-chip and work-tool interfaces due to tool coating, which leads to reduced heat generation at the cutting zones. d. Establishes that Undulating surface topographies on cutting tips tend to hold coating materials longer in the valleys, thus giving enhanced protection to the tool and the tool can cut faster by 40% and last 60% longer than conventional tools on the markets today.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho é o resultado de um projecto experimental que teve como principal objetivo a redução dos tempos de setup, através da implementação da metodologia Single Minute Exchange of Die (SMED) em equipamentos de eletroerosão (EDM) por fio e penetração. Para garantir o sucesso da implementação, após uma revisão bibliográfica centrada no tema SMED, estabelece-se uma metodologia, numa lógica de melhoria contínua análoga a um ciclo PDCA. A metodologia estabelecida envolve as seguintes fases: caracterização da situação inicial, observação, recolha de dados, análise dos dados e implementação SMED. A caracterização da situação inicial visa qualificar a situação encontrada e identificar a zona de atuação - equipamentos em estudo. A observação do processo produtivo é suportada pela ferramenta fluxograma do processo, por sua vez, a recolha de dados visa a avaliação inicial e nessa perspectiva recorre-se à abordagem OEE. Na fase de análise dos dados são introduzidas as ferramentas de análise VSM e diagrama de causa e efeito que auxiliam a identificação de um conjunto de acções de melhoria, a realizar previamente à fase de implementação SMED, culminando assim uma fase PRÉ-SMED. Reunidas as condições ideais iniciou-se a implementação efectiva da metodologia SMED obtendo-se reduções do tempo total de setup superiores a 60%. O presente estudo permite concluir que podem surgir diferenças significativas em diversas aplicações SMED, enfatizando a importância de uma fase PRÉ-SMED de modo a potenciar os resultados alcançados com uma implementação SMED.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: A extrusão apical detritos (EAD) consequência indesejável da instrumentação canalar pode ser associada a dor/edema, podendo atrasar a cicatrização periapical. O nosso trabalho teve como objectivo avaliar e quantificar a EAD em canais instrumentados por sistemas de instrumentação rotatória contínua e reciprocante. Materiais e Métodos: 80 dentes monocanalares sem tratamento endodôntico prévio foram aleatoriamente divididos em 4 grupos (n=20): One Shape® Protaper® NEXT, Hyflex® EDM e WaveOne® Gold. Um tubo de Eppendorf (TdE) foi pesado antecipadamente numa balança analítica de precisão e com um dente inserido foi montado num dispositivo modificado, similar ao método descrito por Myers & Montgomery. Os canais foram instrumentados e irrigados com água destilada. Os dentes instrumentados foram removidos dos TdE e estes preenchidos com água destilada até perfazer 1,5ml, incubados a 70ºC durante cinco dias sendo pesados novamente, calculando a diferença entre o peso inicial e final determinando o peso dos detritos. Os dados foram analisados estatisticamente utilizando o IBM SPSS Statistics 22, considerando α=0,05. Efetuaram-se testes Kruskal-Wallis e post-hoc com ajustamento do ρ-value pelo método Dunn-Bonferroni. Resultados: Houve EAD em todas as técnicas de instrumentação. A análise estatística mostrou haver diferenças significativas na EAD entre as técnicas utilizadas (α=0,002). Entre as técnicas WaveOne® Gold e One Shape® (α=0,003), WaveOne® Gold e Protaper® NEXT (α=0,023) e WaveOne® Gold e Hyflex® EDM (α=0,028). Conclusões: A técnica One Shape® apresentou menor EAD e a técnica WaveOne® Gold com movimento reciprocante constitui maior fator de risco tendo apresentado maior EAD. Os resultados deste estudo indicam que os profissionais devem estar cientes para a EAD que pode ocorrer com cada instrumento, o que poderá servir de base para a selecção de um instrumento particular. Implicações clínicas: A escolha do sistema de instrumentação canalar influencia a extrusão de detritos. Fontes de financiamento: Agradecimentos as empresas; Micro-Mega, França, COLTÉNE e Dentsply Maillefer, Suíça.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Educação, Programa de Pós-Graduação em Educação, 2016.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The wire electrical discharge machining (EDM) of 6061 aluminium alloy in terms of material removal rate, kerf/slit width, surface finish and wear of electrode wire for different pulse on time and wire tension was studied. Eight experiments were carried out in a wire EDM machine by varying pulse on time and wire tension. It is found that the material removal rate increases with the increase of pulse on time though the wire tension does not affect the material removal rate. It seems that the higher wire tension facilitates steady machining process, which generates low wear in wire electrode and better surface finish. The surface roughness does not change notably with the variation of pulse on time. The appearance of the machined surfaces is very similar under all the machining conditions. The machined surface contains solidified molten material, splash of materials and blisters. The increase of the pulse on time increases the wear of wire electrode due to the increase of heat input. The wear of wire electrode generates tapered slot which has higher kerf width at top side than that at bottom side. The higher electrode wear introduces higher taper.