934 resultados para Drug Detection Tests.


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The diagnosis of a drug hypersensitivity reaction (DHR) is a challenging task because multiple and complex mechanisms are involved. Better understanding of immunologic pathomechanisms in DHRs and rapid progress in cellular-based in-vitro tests can help to adjust the correct diagnostic strategy to individual patients with different clinical manifestations of drug allergy. Thus, drug hypersensitivity diagnosis needs to rely on a combination of medical history and different in vivo and in vitro tests. In this article, the authors discuss current in vitro techniques, most recent findings, and new promising tools in the diagnosis of T-cell-mediated drug hypersensitivity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The lymphocyte transformation test (LTT) is used for in vitro diagnosis of drug hypersensitivity reactions. While its specificity is over 90%, sensitivity is limited and depends on the type of reaction, drug and possibly time interval between the event and analysis. Removal of regulatory T cells (Treg/CD25(hi)) from in vitro stimulated cell cultures was previously reported to be a promising method to increase the sensitivity of proliferation tests. Objective: The aim of this investigation is to evaluate the effect of removal of regulatory T cells on the sensitivity of the LTT. Methods: Patients with well-documented drug hypersensitivity were recruited. Peripheral blood mononuclear cells, isolated CD3(+) and CD3(+) T cells depleted of the CD25(hi) fraction were used as effector cells in the LTT. Irrelevant drugs were also included to determine specificity. (3)H-thymidine incorporation was utilized as the detection system and results were expressed as a stimulation index (SI). Results: SIs of 7/11 LTTs were reduced after a mean time interval of 10.5 months (LTT 1 vs. LTT 2). Removal of the CD25(hi) fraction, which was FOXP3(+) and had a suppressive effect on drug-induced proliferation, resulted in an increased response to the relevant drugs. Sensitivity was increased from 25 to 82.35% with dramatically enhanced SI (2.05 to 6.02). Specificity was not affected. Conclusion: Removal of Treg/CD25(hi) cells can increase the frequency and strengths of drug-specific proliferation without affecting specificity. This approach might be useful in certain drug hypersensitivity reactions with borderline responses or long time interval since the hypersensitivity reaction. © 2014 S. Karger AG, Basel.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

SETTING Drug resistance threatens tuberculosis (TB) control, particularly among human immunodeficiency virus (HIV) infected persons. OBJECTIVE To describe practices in the prevention and management of drug-resistant TB under antiretroviral therapy (ART) programs in lower-income countries. DESIGN We used online questionnaires to collect program-level data on 47 ART programs in Southern Africa (n = 14), East Africa (n = 8), West Africa (n = 7), Central Africa (n = 5), Latin America (n = 7) and the Asia-Pacific (n = 6 programs) in 2012. Patient-level data were collected on 1002 adult TB patients seen at 40 of the participating ART programs. RESULTS Phenotypic drug susceptibility testing (DST) was available in 36 (77%) ART programs, but was only used for 22% of all TB patients. Molecular DST was available in 33 (70%) programs and was used in 23% of all TB patients. Twenty ART programs (43%) provided directly observed therapy (DOT) during the entire course of treatment, 16 (34%) during the intensive phase only, and 11 (23%) did not follow DOT. Fourteen (30%) ART programs reported no access to second-line anti-tuberculosis regimens; 18 (38%) reported TB drug shortages. CONCLUSIONS Capacity to diagnose and treat drug-resistant TB was limited across ART programs in lower-income countries. DOT was not always implemented and drug supplies were regularly interrupted, which may contribute to the global emergence of drug resistance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND  Transmitted HIV-1 drug-resistance mutations(TDR) are transmitted from treatment-failing or treatment-naïve patients. Although prevalence of drug-resistance in treatment-failing patients has declined in developed countries, TDR prevalence has not. Mechanisms causing this paradox are poorly explored. METHODS  We included recently-infected, treatment-naïve patients with genotypic-resistance-tests performed ≤1year post-infection and <2013. Potential risk factors for TDR were analyzed using logistic regression. Association of TDR prevalences with population viral load(PVL) from treatment-patients during 1997-2011 was estimated with Poisson regression for all TDR and individually for most frequent resistance-mutations against each drug class(M184V/L90M/K103N). RESULTS  We included 2421 recently-infected, treatment-naïve patients and 5399 treatment-failing patients. TDR prevalence fluctuated considerably over time. Two opposing developments could explain these fluctuations: generally continuous increases in TDR(Odds Ratio[OR]=1.13,p=0.010), punctuated by sharp decreases when new drug-classes were introduced. Overall, TDR prevalence increased with decreasing PVL(Rate Ratio[RR]=0.91/1000Log10-PVL,p=0.033). Additionally, we observed that the transmitted high-fitness-cost mutation M184V was positively associated with PVL of treatment-failing patients carrying M184V(RR=1.50/100Log10-PVL,p<0.001). Such association was absent and negative for K103N(RR-K103N=1.00/100Log10-PVL,p=0.99) and L90M(RR-L90M=0.75/100Log10-PVL,p=0.022), respectively. CONCLUSIONS  Transmission of antiretroviral drug-resistance is temporarily reduced by the introduction of new drug classes and driven by treatment-failing and treatment-naïve patients. These findings suggest a continuous need for new drugs, early detection/treatment of HIV-1-infection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Detection of HIV-1 p24 antigen permits early identification of primary HIV infection and timely intervention to limit further spread of the infection. Principally, HIV screening should equally detect all viral variants, but reagents for a standardised test evaluation are limited. Therefore, we aimed to create an inexhaustible panel of diverse HIV-1 p24 antigens. METHODS We generated a panel of 43 recombinantly expressed virus-like particles (VLPs), containing the structural Gag proteins of HIV-1 subtypes A-H and circulating recombinant forms (CRF) CRF01_AE, CRF02_AG, CRF12_BF, CRF20_BG and group O. Eleven 4th generation antigen/antibody tests and five antigen-only tests were evaluated for their ability to detect VLPs diluted in human plasma to p24 concentrations equivalent to 50, 10 and 2 IU/ml of the WHO p24 standard. Three tests were also evaluated for their ability to detect p24 after heat-denaturation for immune-complex disruption, a pre-requisite for ultrasensitive p24 detection. RESULTS Our VLP panel exhibited an average intra-clade p24 diversity of 6.7%. Among the 4th generation tests, the Abbott Architect and Siemens Enzygnost Integral 4 had the highest sensitivity of 97.7% and 93%, respectively. Alere Determine Combo and BioRad Access were least sensitive with 10.1% and 40.3%, respectively. Antigen-only tests were slightly more sensitive than combination tests. Almost all tests detected the WHO HIV-1 p24 standard at a concentration of 2 IU/ml, but their ability to detect this input for different subtypes varied greatly. Heat-treatment lowered overall detectability of HIV-1 p24 in two of the three tests, but only few VLPs had a more than 3-fold loss in p24 detection. CONCLUSIONS The HIV-1 Gag subtype panel has a broad diversity and proved useful for a standardised evaluation of the detection limit and breadth of subtype detection of p24 antigen-detecting tests. Several tests exhibited problems, particularly with non-B subtypes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Hepatitis B viruses (HBV) harboring mutations in the a-determinant of the Hepatitis B surface antigen (HBsAg) are associated with reduced reactivity of HBsAg assays. OBJECTIVES To evaluate the sensitivity and specificity of three HBsAg point-of-care tests for the detection of HBsAg of viruses harboring HBsAg mutations. STUDY DESIGN A selection of 50 clinical plasma samples containing HBV with HBsAg mutations was used to evaluate the performance of three HBsAg point-of-care tests (Vikia(®), bioMérieux, Marcy-L'Étoile, France. Alere Determine HBsAg™, Iverness Biomedical Innovations, Köln, Germany. Quick Profile™, LumiQuick Diagnostics, California, USA) and compared to the ARCHITECT HBsAg Qualitative(®) assay (Abbott Laboratories, Sligo, Ireland). RESULTS The sensitivity of the point-of-care tests ranged from 98% to 100%. The only false-negative result occurred using the Quick Profile™ assay with a virus harboring a D144A mutation. CONCLUSIONS The evaluated point-of-care tests revealed an excellent sensitivity in detecting HBV samples harboring HBsAg mutations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The in-house Carba-NP and Blue-Carba tests were compared using 30 carbapenemase- and 33 non-producing Enterobacteriaceae. Tests were read by three operators. 100% sensitivity was reported for both tests, but Carba-NP was slightly more specific than Blue-Carba (98.9% vs. 91.7%). We describe potential sources of error during tests' preparation and reading.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, the authors provide a methodology to design nonparametric permutation tests and, in particular, nonparametric rank tests for applications in detection. In the first part of the paper, the authors develop the optimization theory of both permutation and rank tests in the Neyman?Pearson sense; in the second part of the paper, they carry out a comparative performance analysis of the permutation and rank tests (detectors) against the parametric ones in radar applications. First, a brief review of some contributions on nonparametric tests is realized. Then, the optimum permutation and rank tests are derived. Finally, a performance analysis is realized by Monte-Carlo simulations for the corresponding detectors, and the results are shown in curves of detection probability versus signal-to-noise ratio

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents different test alternatives which can be used on-site in a PV installation to detect potential induced degradation (PID) in modules. The testing procedures proposed are: thermal imaging; electroluminescence imaging; open circuit voltage measurements; operating voltage measurements; IV curve measurements; and dark IV curve measurements. Advantages and disadvantages of each test are reported.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mealiness is known as an important internal quality attribute of fruits/vegetables, which has significant influence on consumer purchasing decisions. Mealiness has been a topic of research interest over the past several decades. A number of destructive and nondestructive techniques are introduced for mealiness detection. Nondestructive methods are more interesting because they are rapid, noninvasive, and suitable for real-time purposes. In this review, the concept of mealiness is presented for potato, apple, and peach, followed by an in-depth discussion about applications of destructive and nondestructive techniques developed for mealiness detection. The results suggest the potential of electromagnetic-based techniques for nondestructive mealiness evaluation. Further investigations are in progress to find more appropriate nondestructive techniques as well as cost and performance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This Article Right arrow Full Text Right arrow Full Text (PDF) Right arrow Supplemental material Right arrow Alert me when this article is cited Right arrow Alert me if a correction is posted Services Right arrow Similar articles in this journal Right arrow Similar articles in PubMed Right arrow Alert me to new issues of the journal Right arrow Download to citation manager Right arrow Reprints and Permissions Right arrow Copyright Information Right arrow Books from ASM Press Right arrow MicrobeWorld Citing Articles Right arrow Citing Articles via HighWire Right arrow Citing Articles via Google Scholar Google Scholar Right arrow Articles by Lee, N. Right arrow Articles by McCarthy, J. Right arrow Search for Related Content PubMed Right arrow PubMed Citation Right arrow Articles by Lee, N. Right arrow Articles by McCarthy, J. Right arrow Pubmed/NCBI databases * Substance via MeSH Previous Article | Next Article Journal of Clinical Microbiology, August 2006, p. 2773-2778, Vol. 44, No. 8 0095-1137/06/$08.00+0 doi:10.1128/JCM.02557-05 Copyright © 2006, American Society for Microbiology. All Rights Reserved. Effect of Sequence Variation in Plasmodium falciparum Histidine- Rich Protein 2 on Binding of Specific Monoclonal Antibodies: Implications for Rapid Diagnostic Tests for Malaria{dagger} Nelson Lee,1,2 Joanne Baker,2 Kathy T. Andrews,1 Michelle L. Gatton,1,3 David Bell,4 Qin Cheng,2,3 and James McCarthy1* Australian Centre for International and Tropical Health and Nutrition, Queensland Institute of Medical Research and School of Population Health, University of Queensland, Queensland, Australia,1 Department of Drug Resistance and Diagnostics, Australian Army Malaria Institute, Brisbane, Australia,2 Malaria Drug Resistance and Chemotherapy, Queensland Institute of Medical Research, Queensland, Australia,3 World Health Organization, Regional Office for the Western Pacific, Manila, Philippines4 Received 8 December 2005/ Returned for modification 23 February 2006/ Accepted 26 May 2006 The ability to accurately diagnose malaria infections, particularly in settings where laboratory facilities are not well developed, is of key importance in the control of this disease. Rapid diagnostic tests (RDTs) offer great potential to address this need. Reports of significant variation in the field performance of RDTs based on the detection of Plasmodium falciparum histidine-rich protein 2 (HRP2) (PfHRP2) and of significant sequence polymorphism in PfHRP2 led us to evaluate the binding of four HRP2-specific monoclonal antibodies (MABs) to parasite proteins from geographically distinct P. falciparum isolates, define the epitopes recognized by these MABs, and relate the copy number of the epitopes to MAB reactivity. We observed a significant difference in the reactivity of the same MAB to different isolates and between different MABs tested with single isolates. When the target epitopes of three of the MABs were determined and mapped onto the peptide sequences of the field isolates, significant variability in the frequency of these epitopes was observed. These findings support the role of sequence variation as an explanation for variations in the performance of HRP2-based RDTs and point toward possible approaches to improve their diagnostic sensitivities