985 resultados para Differential pulse voltammetry
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The Indanthrene Olive Green B (C.I. Vat Green 3; C.I. 69500), VG3 dye, a vat dye bearing an anthraquinonoid group and a ketonic group, can be detected by differential pulse voltammetry in alkaline solution using glassy carbon electrode. on the adsorbed form the dyes are reduced into three cathodic steps at -0.54 V, -0.65 V and -0.93 V vs Ag/AgCl. The leuco form generated after previous electrolysis at controlled potential of -1 V can be detected by voltammetry due to its reoxidation peak at -0.08 V. An analytical method is proposed for determining the vat dye using modified glassy carbon electrode by electrochemical activation in alkaline medium. Linear relationship was observed between l(Pu) vs concentration from I X 10(-5) mol L-1 to 6.0 X 10(-4) mol L-1. The detection limit was calculated to be 9.3 X 10(-6) mol L-1. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
A simple, rapid inexpensive voltammetric method have been developed for the quantitative determination of albendazole (ABZ) as the pure assay, by direct dissolution of commercial tablets in HCl solutions. Studies with linear sweep (LSV), square-wave (SWV) and differential pulse voltammetry (DPV) were carried out ABZ in aqueous medium at a glassy carbon electrode. A well defined irreversible oxidation peak current was obtained at 1,00V vs. SCE. The method permits a precise quantitative determination of ABZ using the standard addition method. The detection limits for the three voltammetric techniques were found to be 3.0 x 10(-5) M (LSV), 6.2 x 10(-5) M (SWV) and 4.0 x 10(-5) M (DPV).
Resumo:
A mercury-free electrode chemically modified with carbon paste containing dimethylglyoxime was used for determination of nickel in fuel ethanol. The instrumental parameters and composition of the modified paste were optimized. The analytical curve for nickel determination from 5.0 x 10(-9) to 5.0 x10(-7) mol(-1) was obtained using 25 min of accumulation time. The detection limit and amperometric sensitivity obtained for this method were 2.7 x 10 mol(-1) and 5.2 x 10(8) mu A mol(-1) L, respectively. The values for nickel concentration in four commercial samples of fuel ethanol were obtained in the range of 1.1 x 10(-8) to 6.9 x 10(-8) mol(-1). A comparison to graphite furnace atomic absorption spectrometry (GFAAS) was performed for nickel determination in commercial samples of ethanol.
Resumo:
Primaquine, an antimalarial drug, presents a well-defined oxidation peak around +0.6V vs SCE at a glassy carbon electrode that can be used for its determination. Calibration graphs were obtained for primaquine in B-R buffer pH 4.0 from 3.00 x 10(-5) mol L-1 to 1.00 x 10(-2) mol L-1 using linear-scan voltammetry and 3.00 x 10(-5) mol L-1 to 1.00 x 10(-2) mol L-1 using differential pulse or square-wave voltammetry. The correspondent detection limits was 9.4 mu g mL(-1); 4.2 and 1.8 mu g mL(-1), respectively. All the voltammetric methods were applied with success in direct determination of the primaquine in commercial tablets without separation or extraction procedures.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The intension of this paper was to review and discuss some of the current quantitative analytical procedures which are used for quality control of pharmaceutical products. The selected papers were organized according to the analytical technique employed. Several techniques like ultraviolet/visible spectrophotometry, fluorimetry, titrimetry, electroanalytical techniques, chromatographic methods (thin-layer chromatography, gas chromatography and high-performance liquid chromatography), capillary electrophoresis and vibrational spectroscopies are the main techniques that have been used for the quantitative analysis of pharmaceutical compounds. In conclusion, although simple techniques such as UV/VIS spectrophotometry and TLC are still extensively employed, HPLC is the most popular instrumental technique used for the analysis of pharmaceuticals. Besides, a review of recent works in the area of pharmaceutical analysis showed a trend in the application of techniques increasingly rapid such as ultra performance liquid chromatography and the use of sensitive and specific detectors as mass spectrometers.
Resumo:
A poly glutamic acid film modified electrode exhibited a catalytic response toguanosine oxidation potential and higher peak current value. Linear concentration curve was obtained in the concentration interval of 1.0 a 10.0 μmol L-1 in 0.04 mol L-1 B-R buffer pH 2.0 with a detection limit of 0.198 μmol L-1. The electrode was used for the determination of guanosine in the potential of +1.1 V (vs. Ag/AgCl) using differential pulse voltammetry (DPV) at urine sample with good recovery. © 2010 by CEE.
Resumo:
Pós-graduação em Química - IQ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Química - IQ