905 resultados para Device geometries


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Cardiovascular urgencies are frequent reasons for seeking medical care. Prompt and accurate medical diagnosis is critical to reduce the morbidity and mortality of these conditions.Objective:To evaluate the use of a pocket-size echocardiography in addition to clinical history and physical exam in a tertiary medical emergency care.Methods:One hundred adult patients without known cardiac or lung diseases who sought emergency care with cardiac complaints were included. Patients with ischemic changes in the electrocardiography or fever were excluded. A focused echocardiography with GE Vscan equipment was performed after the initial evaluation in the emergency room. Cardiac chambers dimensions, left and right ventricular systolic function, intracardiac flows with color, pericardium, and aorta were evaluated.Results:The mean age was 61 ± 17 years old. The patient complaint was chest pain in 51 patients, dyspnea in 32 patients, arrhythmia to evaluate the left ventricular function in ten patients, hypotension/dizziness in five patients and edema in one patient. In 28 patients, the focused echocardiography allowed to confirm the initial diagnosis: 19 patients with heart failure, five with acute coronary syndrome, two with pulmonary embolism and two patients with cardiac tamponade. In 17 patients, the echocardiography changed the diagnosis: ten with suspicious of heart failure, two with pulmonary embolism suspicious, two with hypotension without cause, one suspicious of acute coronary syndrome, one of cardiac tamponade and one of aortic dissection.Conclusion:The focused echocardiography with pocket-size equipment in the emergency care may allow a prompt diagnosis and, consequently, an earlier initiation of the therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes the employment relationship on the basis of the notion of access. We argue that the degree of access provided by a job is an incentive to activate the employee’s self-actualization needs. We investigate the effect of access on the workers’ performance through an agency model and provide a number of propositions with practical implications for personnel policies. Our results are consistent with the intuition emerged from the real business practice as well as with many of the arguments on the substitutive role between monetary and non-monetary incentives frequently reported in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this article is to explain what factors determine the use of seniority-based pay for production workers in Spanish manufacturing industry. The data used in order to achieve these objectives was taken from 774 Spanish industrial plants. The estimation of several ordered probit models enabled us to see that in firms where it was more costly for management to engage in opportunistic behaviour, deferred payment shows a negative relation to the use of devices, like monitoring or incentive payment, designed to align workers’ objectives with those of the company.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudi elaborat a partir d’una estada a l'Imperial College of London, Gran Bretanya, entre setembre i desembre 2006. Disposar d'una geometria bona i ben definida és essencial per a poder resoldre eficientment molts dels models computacionals i poder obtenir uns resultats comparables a la realitat del problema. La reconstrucció d'imatges mèdiques permet transformar les imatges obtingudes amb tècniques de captació a geometries en formats de dades numèriques . En aquest text s'explica de forma qualitativa les diverses etapes que formen el procés de reconstrucció d'imatges mèdiques fins a finalment obtenir una malla triangular per a poder‐la processar en els algoritmes de càlcul. Aquest procés s'inicia a l'escàner MRI de The Royal Brompton Hospital de Londres del que s'obtenen imatges per a després poder‐les processar amb les eines CONGEN10 i SURFGEN per a un entorn MATLAB. Aquestes eines les han desenvolupat investigadors del Bioflow group del departament d'enginyeria aeronàutica del Imperial College of London i en l'ultim apartat del text es comenta un exemple d'una artèria que entra com a imatge mèdica i surt com a malla triangular processable amb qualsevol programari o algoritme que treballi amb malles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction/objectives: Multipatient use of a single-patient CBSD occurred inan outpatient clinic during 4 to 16 months before itsnotification. We looked for transmission of blood-bornepathogens among exposed patients.Methods: Exposed patients underwent serology testing for HBV,HCV and HIV. Patients with isolated anti-HBc receivedone dose of hepatitis B vaccine to look for a memoryimmune response. Possible transmissions were investigatedby mapping visits and sequencing of the viral genomeif needed.Results: Of 280 exposed patients, 9 had died without suspicionof blood-borne infection, 3 could not be tested, and 5declined investigations. Among the 263 (93%) testedpatients, 218 (83%) had negative results. We confirmeda known history of HCV infection in 6 patients (1 coinfectedby HIV), and also identified resolved HBVinfection in 37 patients, of whom 18 were alreadyknown. 2 patients were found to have a previouslyunknown HCV infection. According to the time elapsedfrom the closest previous visit of a HCV-infected potentialsource patient, we could rule out nosocomial transmissionin one case (14 weeks) but not in the other (1day). In the latter, however, transmission was deemedvery unlikely by 2 reference centers based on thesequences of the E1 and HVR1 regions of the virus.Conclusion: We did not identify any transmission of blood-bornepathogens in 263 patients exposed to a single-patientCBSD, despite the presence of potential source cases.Change of needle and disinfection of the device betweenpatients may have contributed to this outcome.Although we cannot exclude transmission of HBV, previousacquisition in endemic countries is a more likelyexplanation in this multi-national population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé: Introduction : L'utilisation de méthodes endoscopiques peu invasives est en constante augmentation pour le traitement des lésions tumorales précoces de l'oesophage. Le but du traitement comprend l'éradication complète de tous les foyers de dysplasie ou de carcinome in situ, notamment dans les métaplasies intestinales de l'oesophage de Barrett, qui peuvent dégénérer en adénocarcinome. Plusieurs techniques d'ablation de la muqueuse oesophagienne (laser, argon plasma, electrocoagulation, photothérapie dynamique, résection endoscopique) ont été utilisées jusqu'à présent, mais aucune n'a vraiment donné entière satisfaction. Les techniques actuelles de résections endoscopiques par fibroscopie sont entre autres limitées par le grand nombre de séances nécessaires à l'éradication complète de la lésion et par la petite taille des fragments de muqueuse obtenus, ce qui rend l'analyse histologique difficile. Dans notre étude animale, nous avons évalué la faisabilité, l'efficacité et la sécurité d'une méthode de résection endoscopique à l'aide d'un nouvel oesophagoscope rigide. Matériel et méthode : Le résectoscope est formé d'un oesophagoscope rigide avec une fenêtre distale transparente à travers laquelle la muqueuse et une partie de la sous-muqueuse sont aspirées et ensuite réséquées avec une anse thermique. Les diverses fenêtres utilisées ont une taille comprise entre 2.2 et 4.4 cm. Le mouton a été choisi en raison de la ressemblance de son oesophage avec celui de l'humain en ce qui concerne l'épaisseur de son oesophage et sa structure histologique. Nous avons effectué 55 résections hémi-circonférentielles sur 21 animaux et 11 résections circonférentielles sur 11 autres. La Mitomycine-C, une substance qui inhibe la prolifération fibroblastique, a été utilisée dans 8 résections circonférentielles à différents intervalles de temps afin d'empêcher la survenue de sténoses oesophagiennes. Résultats : Toutes les résections hémi-circonférentielles ont permis d'obtenir des fragments compacts de tissu avec des bords nets, ce qui permet une excellente étude histologique. La surface du tissu prélevé était en corrélation avec la taille de la fenêtre du resectoscope. Nous avons ainsi pu obtenir des fragments avec des dimensions comprises entre 6 et 12 cm2. Pour les résections circonférentielles, les tissus étaient obtenus en 2 parties, en inversant de 180° la position de l'appareil. La profondeur de la résection a été optimale dans 58 cas sur 65 avec une découpe précise au niveau de la sous-muqueuse sans lésion de la couche musculaire sous- jacente. Il n'y a pas eu de complications après les résections hémi-circonférentielles. Les complications engendrées par les résections circonférentielles (sténose, perforation) n'ont plus été rencontrées après application locale de Mitomycine-C administrée à des intervalles de temps bien précis. Conclusion : Notre méthode de résection endoscopique de la muqueuse oesophagienne offre une nouvelle approche très prometteuse par rapport aux options déjà disponibles. Elle apparaît supérieure en ce qui concerne la taille de tissu prélevé, la précision et régularité de la profondeur de résection, ainsi que la facilité et sûreté du diagnostic histologique et des marges de sécurité. Les résections hémi-circonférentielles se sont révélées sûres chez le modèle animal. Cette nouvelle technique mérite de plus amples investigations pour les résections circonférentielles avant son utilisation chez l'humain. Abstract: Background and Study Aims: We undertook this retrospective study to evaluate the frequency and prognosis of endoscopic treatment of laterally spreading tumors (LSTs) in the rectum. The recurrence rate for lesions of the lower rectum was compared with that of the upper rectum. Patients and Methods: During the period from July 1989 to June 2002, a total of 1237 rectal tumors were detected. LSTs accounted for 6.9% (85/1237) of all rectal tumors. A total of 224 tumors of the lower rectum were detected among the 1237 rectal tumors. LSTs accounted for 16.1 % (36/224) of all the lower rectal tumors. From 85 LST lesions, 67 were evaluated for their prognosis after endoscopic mucosal resection (EMR). Patients whose LSTs had been resected were followed up by endoscopy at the following frequencies: once 15 (22.4%); twice (more than 1 year), 20 (29.9%); three times (more than 3 years), 21(31.3%); and four times or more (more than 5 years), 11 (16.4%). Results: A total of 67 patients with endoscopically treated LSTs were followed up by endoscopy. We observed recurrences in two lesions of the upper rectum (2/38, 5.3%) and five lesions of the lower rectum (5/29, 17.2%) (P = 0.2364); all seven lesions were resected piecemeal. LSTs whose horizontal margin reached the pectinate line frequently recurred in the lower rectum, at a rate of 80% (4/5). However, all patients were completely cured by additional endoscopic resections, the greatest number of treatments being four. Conclusion: For early detection of recurrence and successful endoscopic cure, further colonoscopic examination within a few months after the first treatment is necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The World Health Organization (WHO) criteria for the diagnosis of osteoporosis are mainly applicable for dual X-ray absorptiometry (DXA) measurements at the spine and hip levels. There is a growing demand for cheaper devices, free of ionizing radiation such as promising quantitative ultrasound (QUS). In common with many other countries, QUS measurements are increasingly used in Switzerland without adequate clinical guidelines. The T-score approach developed for DXA cannot be applied to QUS, although well-conducted prospective studies have shown that ultrasound could be a valuable predictor of fracture risk. As a consequence, an expert committee named the Swiss Quality Assurance Project (SQAP, for which the main mission is the establishment of quality assurance procedures for DXA and QUS in Switzerland) was mandated by the Swiss Association Against Osteoporosis (ASCO) in 2000 to propose operational clinical recommendations for the use of QUS in the management of osteoporosis for two QUS devices sold in Switzerland. Device-specific weighted "T-score" based on the risk of osteoporotic hip fractures as well as on the prediction of DXA osteoporosis at the hip, according to the WHO definition of osteoporosis, were calculated for the Achilles (Lunar, General Electric, Madison, Wis.) and Sahara (Hologic, Waltham, Mass.) ultrasound devices. Several studies (totaling a few thousand subjects) were used to calculate age-adjusted odd ratios (OR) and area under the receiver operating curve (AUC) for the prediction of osteoporotic fracture (taking into account a weighting score depending on the design of the study involved in the calculation). The ORs were 2.4 (1.9-3.2) and AUC 0.72 (0.66-0.77), respectively, for the Achilles, and 2.3 (1.7-3.1) and 0.75 (0.68-0.82), respectively, for the Sahara device. To translate risk estimates into thresholds for clinical application, 90% sensitivity was used to define low fracture and low osteoporosis risk, and a specificity of 80% was used to define subjects as being at high risk of fracture or having osteoporosis at the hip. From the combination of the fracture model with the hip DXA osteoporotic model, we found a T-score threshold of -1.2 and -2.5 for the stiffness (Achilles) determining, respectively, the low- and high-risk subjects. Similarly, we found a T-score at -1.0 and -2.2 for the QUI index (Sahara). Then a screening strategy combining QUS, DXA, and clinical factors for the identification of women needing treatment was proposed. The application of this approach will help to minimize the inappropriate use of QUS from which the whole field currently suffers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a theoretical analysis of democratization processes in which an elite extends the franchise to the poor when threatened with a revolution. The poor could govern without changing the political system by maintaining a continuous revolutionary threat on the elite. Revolutionary threats, however, are costly to the poor and democracy is a superior sys- tem in which political agreement is reached through costless voting. This provides a rationale for democratic transitions that has not been discussed in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With salaries subjected to scrutiny more than ever, it is increasingly important that the process by which they are determined be understood and justifiable. Both public and private organisations now routinely rely on so-called “job evaluation” as a means of constructing an appropriate pay-scale and as such it is ever more necessary that we appreciate how this system works and that we recognise its limits. Only with such an understanding of the way in which salaries are set can we hope to have a meaningful discussion of their economic function. This paper aims to expound the details of job evaluation both in theory and in practice, and critically assess its shortcomings. In Section 1 below we describe the job evaluation system and in Section 2 we briefly outline the history and the usage of the system in both the private and the public sector. In Section 3 we theoretically analyse the often unstated but nonetheless implicit assumptions made by practitioners of the art of job evaluation. Section 4 applies the analysis of Section 3 to review a particular and important case study, namely The Senior Salaries Review of the Welsh Assembly 2004. Section 5 concludes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the inception of cardiopulmonary bypass (CPB), little progress has been made concerning the design of cardiotomy suction (CS). Because this is a major source of hemolysis, we decided to test a novel device (Smartsuction [SS]) specifically aimed at minimizing hemolysis during CPB in a clinical setting. Block randomization was carried out on a treated group (SS, n=28) and a control group (CTRL, n=26). Biochemical parameters were taken pre-, peri-, and post CPB and were compared between the two groups using the Student's t-test with statistical significance when P<0.05. No significant differences in patient demographics were observed between the two groups. Lactate dehydrogenase (LDH) and plasma free hemoglobin (PFH) pre-CPB were comparable for the CTRL and SS groups, respectively. LDH peri-CPB was 275+/-100 U/L versus 207+/-83 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 486+/-204 mg/L versus 351+/-176 mg/L for the CTRL and SS groups, respectively (P<0.05). LDH post CPB was 354+/-116 U/L versus 275+/-89 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 549+/-271 mg/L versus 460+/-254 mg/L for the CTRL and SS groups, respectively (P<0.05). Preoperative hematocrit (Hct) of 43+/-5% (CTRL) versus 37+/-5% (SS), and hemoglobin (Hb) of 141+/-16 g/L (CTRL) versus 122+/-17 g/L (SS) were significantly lower in the SS group. However, when normalized (N), the SS was capable of conserving Hct, Hb, and erythrocyte count perioperatively. Erythrocytes (N) were 59+/-5% (CTRL) versus 67+/-9% (SS); Hct (N) was 59+/-6% (CTRL) versus 68+/-9% (SS), and Hb (N) was 61+/-6% (CTRL) versus 70+/-10% (SS) (all P<0.05). This novel SS device evokes significantly lowered blood PFH and LDH values peri- and post CPB compared with the CTRL blood using a CS system. The SS may be a valuable alternative compared to traditional CS techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present a prototype of a control flow for an a posteriori drug dose adaptation for Chronic Myelogenous Leukemia (CML) patients. The control flow is modeled using Timed Automata extended with Tasks (TAT) model. The feedback loop of the control flow includes the decision-making process for drug dose adaptation. This is based on the outputs of the body response model represented by the Support Vector Machine (SVM) algorithm for drug concentration prediction. The decision is further checked for conformity with the dose level rules of a medical guideline. We also have developed an automatic code synthesizer for the icycom platform as an extension of the TIMES tool.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Dissection during laparoscopic surgery produces smoke containing potentially toxic substances. The aim of the present study was to analyze smoke samples produced during laparoscopic colon surgery using a bipolar vessel sealing device (LigaSuretrade mark). METHODS: Four consecutive patients undergoing left-sided colectomy were enrolled in this pilot study. Smoke was produced by the use of LigaSuretrade mark. Samples (5,5l) were evacuated from the pneumoperitoneum in a closed system into a reservoir. Analysis was performed with CO2-laser-based photoacoustic spectroscopy and confirmed by a Fourier-transform infrared spectrum. The detected spectra were compared to the available spectra of known toxins. RESULTS: Samples from four laparoscopic sigmoid resections were analyzed. No relevant differences were noted regarding patient and operation characteristics. The gas samples were stable over time proven by congruent control measurements as late as 24 h after sampling. The absorption spectra differed considerably between the patients. One broad absorption line at 100 ppm indicating H2O and several unknown molecules were detected. With a sensitivity of alpha min ca 10-5 cm-1 no known toxic substances like phenol or indole were identified. CONCLUSION: The use of a vessel sealing device during laparoscopic surgery does not produce known toxic substances in relevant quantity. Further studies are needed to identify unknown molecules and to analyze gas emission under various conditions.