996 resultados para Motion Compensation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of two-dimensional micromagnetic modeling of magnetization patterns in Permalloy ellipses under the influence of rotating constant-amplitude magnetic fields are discussed. Ellipses of two different lateral sizes have been studied, 0.5m x 1.5m and 1m x 3m. The amplitude of the rotating magnetic field was varied between simulations with the condition that it must be large enough to saturate or nearly saturate the ellipse with the field applied along the long axis of the ellipse. For the smaller ellipse size it is found that the magnetization pattern forms an S state and the direction of the net magnetization lags behind the direction of the applied field. At a critical angle of the rotating magnetic field the direction of the magnetization switches by a large angle to a new S state. Both the critical angle and the angle interval of the switch depend on field amplitude. For this new state, it is instead the applied field direction that lags behind the magnetization direction. The transient magnetization patterns correspond to multi-domain patterns including two vortices, but this state never exists for the equilibrated magnetization patterns. The behavior of the larger ellipse in rotating field is different. With the field applied along the long-axis of the ellipse, the magnetization of the ellipse is nearly saturated with a vortex close to each apex of the ellipse. As the field is rotated, this magnetization pattern remains and the net-magnetization direction lags behind the direction of the field until for a certain angle of the applied field an equilibrium multi-domain state is created. Comparisons are made with corresponding experimental results obtained by performing in-field magnetic force microscopy on Permalloy ellipses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motion of single micrometer-sized magnetic particles on patterned magnetic surfaces is controlled by a rotating magnetic field (see Figure and cover). Patterns of thin-film magnetic elements are tailored to form transport lines. Individual particles are separated by adding junctions to the transport lines. The method can improve existing applications in biotechnology and generate new ones in life sciences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laughter is a frequently occurring social signal and an important part of human non-verbal communication. However it is often overlooked as a serious topic of scientific study. While the lack of research in this area is mostly due to laughter’s non-serious nature, it is also a particularly difficult social signal to produce on demand in a convincing manner; thus making it a difficult topic for study in laboratory settings. In this paper we provide some techniques and guidance for inducing both hilarious laughter and conversational laughter. These techniques were devised with the goal of capturing mo- tion information related to laughter while the person laughing was either standing or seated. Comments on the value of each of the techniques and general guidance as to the importance of atmosphere, environment and social setting are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We address the problem of multi-target tracking in realistic crowded conditions by introducing a novel dual-stage online tracking algorithm. The problem of data-association between tracks and detections, based on appearance, is often complicated by partial occlusion. In the first stage, we address the issue of occlusion with a novel method of robust data-association, that can be used to compute the appearance similarity between tracks and detections without the need for explicit knowledge of the occluded regions. In the second stage, broken tracks are linked based on motion and appearance, using an online-learned linking model. The online-learned motion-model for track linking uses the confident tracks from the first stage tracker as training examples. The new approach has been tested on the town centre dataset and has performance comparable with the present state-of-the-art

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Manipulator motion planning is a task which relies heavily on the construction of a configuration space prior to path planning. However when fast real-time motion is needed, the full construction of the manipulator's high-dimensional configu-ration space can be too slow and expensive. Alternative planning methods, which avoid this full construction of the manipulator's configuration space are needed to solve this problem. Here, one such existing local planning method for manipulators based on configuration-sampling and subgoal-selection has been extended. Using a modified Artificial Potential Fields (APF) function, goal-configuration sampling and a novel subgoal selection method, it provides faster, more optimal paths than the previously proposed work. Simulation results show a decrease in both runtime and path lengths, along with a decrease in unexpected local minimum and crashing issues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, an improved video encryption method for encrypting the sign bit of motion vectors is proposed based on H.264/AVC, which belongs to selective encryption. This method improves upon previous work involving the sign bit encryption of motion vectors by ensuring the four candidates for the encrypted motion vectors are always located in two orthogonal lines. The improved method can provide a much more effective scrambling effect while keeping the encrypted stream format-compliant and the compression ratio unchanged. The combination of the proposed method with encryption of intra prediction modes can further enhance the scrambling effect, especially for the first few frames which are left clear when only the motion vectors are encrypted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paradoxical kinesia describes the motor improvement in Parkinson's disease (PD) triggered by the presence of external sensory information relevant for the movement. This phenomenon has been puzzling scientists for over 60 years, both in neurological and motor control research, with the underpinning mechanism still being the subject of fierce debate. In this paper we present novel evidence supporting the idea that the key to understanding paradoxical kinesia lies in both spatial and temporal information conveyed by the cues and the coupling between perception and action. We tested a group of 7 idiopathic PD patients in an upper limb mediolateral movement task. Movements were performed with and without a visual point light display, travelling at 3 different speeds. The dynamic information presented in the visual point light display depicted three different movement speeds of the same amplitude performed by a healthy adult. The displays were tested and validated on a group of neurologically healthy participants before being tested on the PD group. Our data show that the temporal aspects of the movement (kinematics) in PD can be moderated by the prescribed temporal information presented in a dynamic environmental cue. Patients demonstrated a significant improvement in terms of movement time and peak velocity when executing movement in accordance with the information afforded by the point light display, compared to when the movement of the same amplitude and direction was performed without the display. In all patients we observed the effect of paradoxical kinesia, with a strong relationship between the perceptual information prescribed by the biological motion display and the observed motor performance of the patients. © 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Respiratory motion introduces complex spatio-temporal variations in the dosimetry of radiotherapy and may contribute towards uncertainties in radiotherapy planning. This study investigates the potential radiobiological implications occurring due to tumour motion in areas of geometric miss in lung cancer radiotherapy. A bespoke phantom and motor-driven platform to replicate respiratory motion and study the consequences on tumour cell survival in vitro was constructed. Human non-small-cell lung cancer cell lines H460 and H1299 were irradiated in modulated radiotherapy configurations in the presence and absence of respiratory motion. Clonogenic survival was calculated for irradiated and shielded regions. Direction of motion, replication of dosimetry by multi-leaf collimator (MLC) manipulation and oscillating lead shielding were investigated to confirm differences in cell survival. Respiratory motion was shown to significantly increase survival for out-of-field regions for H460/H1299 cell lines when compared with static irradiation (p <0.001). Significantly higher survival was found in the in-field region for the H460 cell line (p <0.030). Oscillating lead shielding also produced these significant differences. Respiratory motion and oscillatory delivery of radiation dose to human tumour cells has a significant impact on in- and out-of-field survival in the presence of non-uniform irradiation in this in vitro set-up. This may have important radiobiological consequences for modulated radiotherapy in lung cancer.