951 resultados para Methods validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the scoring obtained by an instrument, which evaluates the ability to read and understand items in the health care setting, according to education and age. METHODS: The short version of the Test of Functional Health Literacy in Adults was administered to 312 healthy participants of different ages and years of schooling. The study was conducted between 2006 and 2007, in the city of São Paulo, Southeastern Brazil. The test includes actual materials such as pill bottles and appointment slips and measures reading comprehension, assessing the ability to read and correctly pronounce a list of words and understand both prose passages and numerical information. Pearson partial correlations and a multiple regression model were used to verify the association between its scores and education and age. RESULTS: The mean age of the sample was 47.3 years(sd=16.8) and the mean education was 9.7 years(sd=5; range: 1 - 17). A total of 32.4% of the sample showed literacy/numeracy deficits, scoring in the inadequate and marginal functional health literacy ranges. Among the elderly (65 years or older) this rate increased to 51.6%. There was a positive correlation between schooling and scores (r=0.74; p<0.01) and a negative correlation between age and the scores (r=-0.259; p<0.01). The correlation between the scores and age was not significant when the effects of education were held constant (rp=-0.031, p=0.584). A significant association (B=3.877, Beta =0.733; p<0.001) was found between schooling and scores. Age was not a significant predictor in this model (B=-0.035, Beta=-0.22; p=0.584). CONCLUSIONS: The short version of the Test of Functional Health Literacy in Adults was a suitable tool to assess health literacy in the study population. The high number of individuals classified as functional illiterates in this test highlights the importance of special assistance to help them properly understand directions for healthcare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A investigação desenvolvida no âmbito do projeto Estratégias de Intervenção socioeducativa em contextos sociais complexos enquadra-se na avaliação das políticas sociais e educativas, em particular no que diz respeito à segurança escolar em contextos marcados pela diversidade e complexidade social e cultural. O processo de avaliação centrou-se na análise das estratégias de intervenção socioeducativa relativas ao problema da violência na escola, desenvolvidas em três escolas de um concelho da Área Metropolitana de Lisboa. Partindo do pressuposto que a violência na escola é um fenómeno multideterminado e multifacetado, a pesquisa centrou-se numa abordagem que enquadra as esferas de intervenção/ação das instituições formais e dos agentes sociais enquanto mecanismos que estruturam e regulam as concepções e práticas de violência na escola. A recolha e sistematização de informação centrou-se, por um lado, nas estratégias de intervenção que têm vindo a ser desenvolvidas localmente pelas escolas, e, por outro, nas perspetivas dos diferentes intervenientes, considerando-se os alunos, osprofessores, as direções escolares e representantes das entidades e instituições locais. Metodologicamente, privilegiou-se o cruzamento de métodos de carácter extensivo e intensivo, combinando técnicas como a Observação Direta, a realização de Entrevistas, de Grupos Focais, de Questionários, e ainda, a Análise de Redes e a Análise Documental. Numa fase posterior, os diversos intervenientes participaram na discussão e análise dos resultados previamente recolhidos, e na validação conjunta de uma metodologia de intervenção que define um conjunto de estratégias gerais de combate às situações de violência na escola e nos territórios educativos. Esta metodologia é o principal produto do projeto e resulta de um processo de avaliação dinâmico e participado. A contribuição que se apresenta no VI Encontro do CIED ocupa-se dos procedimentos de avaliação desenvolvidos no âmbito deste projeto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este projeto teve como objetivo a utilização de ferramentas e conceitos Lean, para análise e implementação da Melhoria de Processos em ambiente fabril, com o intuito de melhorar o sistema produtivo em algumas secções da empresa SCHMITT+SOHN Elevadores. Pretende-se nesta primeira fase uma melhoria na comunicação entre os vários setores fabris, assim como uma melhoria no fluxo dos materiais. Pretende-se igualmente uma simplificação das ações dos operadores nos seus locais de trabalho. Foi para isso necessário, numa fase inicial, a recolha e análise dos diversos dados necessários ao trabalho proposto. Foram feitos diversos VSM’s e análises de fluxo em duas secções da empresa, com o intuito de estudar a situação atual e posteriormente proceder à implementação de um sistema Kanban. Foram também analisados problemas a nível de stocks e armazenamento de matéria-prima e materiais diversos tendo sido concretizadas diversas soluções. O trabalho que apresentamos foi fortemente condicionado por imperativos ditados pela empresa, tendo o nosso estudo e aplicações praticas um suporte de apenas 3 meses. No restante período estivemos condicionados pela empresa a trabalhos de conhecimento do funcionamento da mesma, formação em Kaizen e preparação para as implementações de VSM e Kanban. Nesta fase é ainda prematura a validação dos resultados obtidos nas secções, visto que o processo para a implementação do sistema Kanban ainda se encontra em fase de desenvolvimento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microarray allow to monitoring simultaneously thousands of genes, where the abundance of the transcripts under a same experimental condition at the same time can be quantified. Among various available array technologies, double channel cDNA microarray experiments have arisen in numerous technical protocols associated to genomic studies, which is the focus of this work. Microarray experiments involve many steps and each one can affect the quality of raw data. Background correction and normalization are preprocessing techniques to clean and correct the raw data when undesirable fluctuations arise from technical factors. Several recent studies showed that there is no preprocessing strategy that outperforms others in all circumstances and thus it seems difficult to provide general recommendations. In this work, it is proposed to use exploratory techniques to visualize the effects of preprocessing methods on statistical analysis of cancer two-channel microarray data sets, where the cancer types (classes) are known. For selecting differential expressed genes the arrow plot was used and the graph of profiles resultant from the correspondence analysis for visualizing the results. It was used 6 background methods and 6 normalization methods, performing 36 pre-processing methods and it was analyzed in a published cDNA microarray database (Liver) available at http://genome-www5.stanford.edu/ which microarrays were already classified by cancer type. All statistical analyses were performed using the R statistical software.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrooxidative behavior of citalopram (CTL) in aqueous media was studied by cyclic voltammetry (CV) and square-wave voltammetry (SWV) at a glassy-carbon electrode. The electrochemical behaviour of CTL involves two electrons and two protons in the irreversible and diffusion controlled oxidation of the tertiary amine group. The maximum analytical signal was obtained in a phosphate buffer (pH ¼ 8.2). For analytical purposes, an SWV method and a flow-injection analysis (FIA) system with amperometric detection were developed. The optimised SWV method showed a linear range between 1.10 10 5–1.20 10 4 molL 1, with a limit of detection (LOD) of 9.5 10 6 molL 1. Using the FIA method, a linear range between 2.00 10 6–9.00 10 5 molL 1 and an LODof 1.9 10 6 molL 1 were obtained. The validation of both methods revealed good performance characteristics confirming applicability for the quantification of CTL in several pharmaceutical products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A square-wave voltammetric (SWV) method and a flow injection analysis system with amperometric detection were developed for the determination of tramadol hydrochloride. The SWV method enables the determination of tramadol over the concentration range of 15-75 µM with a detection limit of 2.2 µM. Tramadol could be determined in concentrations between 9 and 50 µM at a sampling rate of 90 h-1, with a detection limit of 1.7 µM using the flow injection system. The electrochemical methods developed were successfully applied to the determination of tramadol in pharmaceutical dosage forms, without any pre-treatment of the samples. Recovery trials were performed to assess the accuracy of the results; the values were between 97 and 102% for both methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two analytical methods for the quality control of dihydrocodeine in commercial pharmaceutical formulations have been developed and compared with reference methods: a square wave voltammetric (SWV) method and a flow injection analysis system with electrochemical detection (FIA-EC). The electrochemical methods proposed were successfully applied to the determination of dihydrocodeine in pharmaceutical tablets and in oral solutions. These methods do not require any pretreatment of the samples, the formulation only being dissolved in a suitable electrolyte. Validation of the methods showed it to be precise, accurate and linear over the concentration range of analysis. The automatic procedure based on a flow injection analysis manifold allows a sampling rate of 115 determinations per hour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To validate a new symphysis-fundal curve for screening fetal growth deviations and to compare its performance with the standard curve adopted by the Brazilian Ministry of Health. METHODS: Observational study including a total of 753 low-risk pregnant women with gestational age above 27 weeks between March to October 2006 in the city of João Pessoa, Northeastern Brazil. Symphisys-fundal was measured using a standard technique recommended by the Brazilian Ministry of Health. Estimated fetal weight assessed through ultrasound using the Brazilian fetal weight chart for gestational age was the gold standard. A subsample of 122 women with neonatal weight measurements was taken up to seven days after estimated fetal weight measurements and symphisys-fundal classification was compared with Lubchenco growth reference curve as gold standard. Sensitivity, specificity, positive and negative predictive values were calculated. The McNemar χ2 test was used for comparing sensitivity of both symphisys-fundal curves studied. RESULTS: The sensitivity of the new curve for detecting small for gestational age fetuses was 51.6% while that of the Brazilian Ministry of Health reference curve was significantly lower (12.5%). In the subsample using neonatal weight as gold standard, the sensitivity of the new reference curve was 85.7% while that of the Brazilian Ministry of Health was 42.9% for detecting small for gestational age. CONCLUSIONS: The diagnostic performance of the new curve for detecting small for gestational age fetuses was significantly higher than that of the Brazilian Ministry of Health reference curve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work presented describes the development and evaluation of two flow-injection analysis (FIA) systems for the automated determination of carbaryl in spiked natural waters and commercial formulations. Samples are injected directly into the system where they are subjected to alkaline hydrolysis thus forming 1-naphthol. This product is readily oxidised at a glassy carbon electrode. The electrochemical behaviour of 1-naphthol allows the development of an FIA system with an amperometric detector in which 1-naphthol determination, and thus measurement of carbaryl concentration, can be performed. Linear response over the range 1.0×10–7 to 1.0×10–5 mol L–1, with a sampling rate of 80 samples h–1, was recorded. The detection limit was 1.0×10–8 mol L–1. Another FIA manifold was constructed but this used a colorimetric detector. The methodology was based on the coupling of 1-naphthol with phenylhydrazine hydrochloride to produce a red complex which has maximum absorbance at 495 nm. The response was linear from 1.0×10–5 to 1.5×10–3 mol L–1 with a detection limit of 1.0×10–6 mol L–1. Sample-throughput was about 60 samples h–1. Validation of the results provided by the two FIA methodologies was performed by comparing them with results from a standard HPLC–UV technique. The relative deviation was <5%. Recovery trials were also carried out and the values obtained ranged from 97.0 to 102.0% for both methods. The repeatability (RSD, %) of 12 consecutive injections of one sample was 0.8% and 1.6% for the amperometric and colorimetric systems, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical behaviour of the herbicide Asulam was studied by cyclic and square wave voltammetry. Asulam may be irreversibly oxidised at a glassy carbon electrode. Maximum currents were obtained at pH=1.9 in aqueous electrolyte solution. Based on the electrochemical behaviour of Asulam, two analytical methodologies were developed for its determination in water samples, using square wave voltammetry (SWV) and flow injection analysis (FIA) coupled with an amperometric detector. Limits of detection of 7.1x10-6 mol L-1 and 1.2x10-8 mol L-1 for SWV and FIA respectively, were achieved. Repeatability was calculated by assessing the relative standard deviation (%) for 10 consecutive determinations of one sample. The found values were 2.1% for SWV and 5.0% for FIA. Validation of the results provided by SWV and FIA methodologies was performed by comparison with results from an HPLC-DAD technique. Good relative deviations were found (<5%). Recovery trials were performed to assess the accuracy of the results and the obtained values were between 84% and 107% for both methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to combat a variety of pests, pesticides are widely used in fruits. Several extraction procedures (liquid extraction, single drop microextraction, microwave-assisted extraction, pressurized liquid extraction, supercritical fluid extraction, solid-phase extraction, solid-phase microextraction, matrix solid-phase dispersion, and stir bar sorptive extraction) have been reported to determine pesticide residues in fruits and fruit juices. The significant change in recent years is the introduction of the Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) methods in these matrices analysis. A combination of techniques reported the use of new extraction methods and chromatography to provide better quantitative recoveries at low levels. The use of mass spectrometric detectors in combination with liquid and gas chromatography has played a vital role to solve many problems related to food safety. The main attention in this review is on the achievements that have been possible because of the progress in extraction methods and the latest advances and novelties in mass spectrometry, and how these progresses have influenced the best control of food, allowing for an increase in the food safety and quality standards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho de Projecto para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Estruturas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amulti-residue methodology based on a solid phase extraction followed by gas chromatography–tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC–MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The state of the art of voltammetric and amperometric methods used in the study and determination of pesticides in crops, food, phytopharmaceutical products, and environmental samples is reviewed. The main structural groups of pesticides, i.e., triazines, organophosphates, organochlorides, nitrocompounds, carbamates, thiocarbamates, sulfonylureas, and bipyridinium compounds are considered with some degradation products. The advantages, drawbacks, and trends in the development of voltammetric and amperometric methods for study and determination of pesticides in these samples are discussed.