Development of electrochemical methods for determination of tramadol - analytical application to pharmaceutical dosage forms


Autoria(s): Garrido, E. Manuela; Garrido, Jorge; Borges, F.; Delerue-Matos, Cristina
Data(s)

25/11/2013

25/11/2013

2003

Resumo

A square-wave voltammetric (SWV) method and a flow injection analysis system with amperometric detection were developed for the determination of tramadol hydrochloride. The SWV method enables the determination of tramadol over the concentration range of 15-75 µM with a detection limit of 2.2 µM. Tramadol could be determined in concentrations between 9 and 50 µM at a sampling rate of 90 h-1, with a detection limit of 1.7 µM using the flow injection system. The electrochemical methods developed were successfully applied to the determination of tramadol in pharmaceutical dosage forms, without any pre-treatment of the samples. Recovery trials were performed to assess the accuracy of the results; the values were between 97 and 102% for both methods.

Identificador

http://dx.doi.org/10.1016/S0731-7085(03)00199-7

http://hdl.handle.net/10400.22/2948

Idioma(s)

eng

Publicador

Elsevier

Relação

Journal of Pharmaceutical and Biomedical Analysis; Vol. 32, Issue 4-5

http://www.sciencedirect.com/science/article/pii/S0731708503001997#

Direitos

openAccess

Palavras-Chave #Tramadol #Square-wave voltammetry #FIA #Electrochemical detection
Tipo

article