993 resultados para perfusion pressure
Increased brain perfusion contrast with T2 -prepared intravoxel incoherent motion (T2prep IVIM) MRI.
Resumo:
The feasibility to measure brain perfusion using intravoxel incoherent motion (IVIM) MRI has been reported recently with currently clinically available technology. The method is intrinsically local and quantitative, but is contaminated by partial volume effects with cerebrospinal fluid (CSF). Signal from CSF can be suppressed by a 180° inversion recovery (180°-IR) magnetization preparation, but this also leads to strong suppression of blood and brain tissue signal. Here, we take advantage of the different T2 relaxations of blood and brain relative to CSF, and implement a T2 -prepared IVIM (T2prep IVIM) inversion recovery acquisition, which permits a recovery of between 43% and 57% of arterial and venous blood magnetization at excitation time compared with the theoretical recovery of between 27% and 30% with a standard 180°-IR. We acquired standard IVIM (IVIM), T2prep IVIM and dynamic susceptibility contrast (DSC) images at 3 T using a 32-multichannel receiver head coil in eight patients with known large high-grade brain tumors. We compared the contrast and contrast-to-noise ratio obtained in the corresponding cerebral blood volume images quantitatively, as well as subjectively by two neuroradiologists. Our findings suggest that quantitative cerebral blood volume contrast and contrast-to-noise ratio, as well as subjective lesion detection, contrast quality and diagnostic confidence, are increased with T2prep IVIM relative to IVIM and DSC.
Resumo:
Purpose: Plasma adiponectin and serum uric acid (SUA) levels are negatively correlated. To better understand the possible mechanisms linking adiponectin and uric acid, we analyzed whether the association between adiponectin and SUA differed by hypertension status (or blood pressure level) and by sex. Methods and materials: We analyzed data from the populationbased CoLaus study (Switzerland). Fasting plasma adiponectin levels were assessed by ELISA and SUA by uricase-PAP. Blood pressure (BP) was measured using a validated automated device and hypertension was defined as having office BP 140/90 mm Hg or being on current antihypertensive treatment. Results: In the 2897 men and 3181 women, aged 35-74, BMI (mean ± SD) was 26.6 ± 4.0 and 25.1 ± 4.8 Kg/m2, systolic blood pressure (SBP) was 132.2 ± 16.6 and 124.8 ± 18.3 mm Hg, median (interquartile range) plasma adiponectin was 6.2 (4.1-9.2) and 10.6 (6.9-15.4) mg/dL, and hypertension prevalence was 42.0% and 30.2%, respectively. The age- and BMI- adjusted partial correlation coefficients between log-adiponectin and SUA were 0.09 and 0.06 in normotensive men and women (P <0.01), and 0.004 (P = 0.88) and 0.15 (P <0.001) in hypertensive men and women, respectively. In median regression adjusted for BMI, insulin, smoking, alcohol consumption, menopausal status and HDL-cholesterol, there was a significant three-way interaction between SUA, SBP and sex for their effect on adiponectin (dependent variable, P = 0.005), as well as interactions between SBP and sex (P = 0.014) and between SUA and sex (P = 0.033). Conclusion: Plasma adiponectin and SUA are negatively associated, independently of BMI and insulin, in a population-based study in Caucasians. However, BP modifies this inverse relationship, as it was significant mainly in women with elevated BP. This observation suggests that the link between adiponectin and SUA may be mediated by sex hormones and the hypertension status.
Resumo:
BACKGROUND: Poor long-term adherence is an important cause of uncontrolled hypertension. We examined whether monitoring drug adherence with an electronic system improves long-term blood pressure (BP) control in hypertensive patients followed by general practitioners (GPs). METHODS: A pragmatic cluster randomised controlled study was conducted over one year in community pharmacists/GPs' networks randomly assigned either to usual care (UC) where drugs were dispensed as usual, or to intervention (INT) group where drug adherence could be monitored with an electronic system (Medication Event Monitoring System). No therapy change was allowed during the first 2 months in both groups. Thereafter, GPs could modify therapy and use electronic monitors freely in the INT group. The primary outcome was a target office BP<140/90 mmHg. RESULTS: Sixty-eight treated uncontrolled hypertensive patients (UC: 34; INT: 34) were enrolled. Over the 12-month period, the likelihood of reaching the target BP was higher in the INT group compared to the UC group (p<0.05). At 4 months, 38% in the INT group reached the target BP vs. 12% in the UC group (p<0.05), and 21% vs. 9% at 12 months (p: ns). Multivariate analyses, taking account of baseline characteristics, therapy modification during follow-up, and clustering effects by network, indicate that being allocated to the INT group was associated with a greater odds of reaching the target BP at 4 months (p<0.01) and at 12 months (p=0.051). CONCLUSION: GPs monitoring drug adherence in collaboration with pharmacists achieved a better BP control in hypertensive patients, although the impact of monitoring decreased with time.
Resumo:
INTRODUCTION: The aim of this study was to assess the blood flow in the feet before and after lower limb revascularization using laser Doppler imaging (LDI). METHODS: Ten patients with critical lower limb ischemia were prospectively enrolled from June to October 2004. All patients underwent successful unilateral surgical interventions including above-knee bypass, distal bypass and endarterectomy. Skin blood flow (SBF) over the plantar surface of both forefeet and heels was measured by LDI 24h before and 10 days after revascularization, expressed in perfusion units (PU), and reported as mean+/-SD. RESULTS: Measurements in the forefoot and heel were similar. Before revascularization mean SBF was significantly lower in the ischemic foot (130+/-71 PU) compared to the contralateral foot (212+/-68 PU), p<0.05. After revascularization a significant increase of the SBF in the forefoot (from 135+/-67 to 202+/-86 PU, p=0.001) and hindfoot (from 148+/-58 to 203+/-83, p=0.001) was observed on the treatment side. However, a large decrease of the SBF was seen in forefoot and hindfoot on the untreated side (from 250+/-123 PU to 176+/-83 and from 208+/-116 to 133+/-40, p=0.001, respectively). CONCLUSION: This study confirms the benefits of revascularization in patients with nonhealing foot lesions due to critical limb ischemia. A significant increase of the SBF was observed on the treatment side. However, an unexpected decrease was observed on the untreated side.
Resumo:
Background And Objectives: Isolated limb perfusion with TNF-alpha and melphalan (TM-ILP) is a limb salvage therapy for non-resectable soft tissue sarcomas (STS) of the extremities. It is indicated for patients for whom amputation or debilitating surgery is the only alternative. It can be used either as an exclusive therapy (in palliation) or as a neo-adjuvant treatment, followed by marginal resection of tumor remnants with minimal functional impairment. Methods: Between February 1992 and March 2006, 57 TM-ILPs were performed on 51 patients with 88% high grade and 84% advanced stage tumors. Results: Mean follow-up is 38.9 months (4-159, median 22 months). Twenty-one percent patients had significant early complications, with 3 major re-operations, and 23% suffered long-lasting complications. Complete response was observed in 25%, partial response in 42%, stable disease in 14% and progressive disease in 14%. Resection of the tumor remnants was possible in 65%. A complementary treatment was necessary in 31%, mostly radiation therapy. A local recurrence was observed in 35%, after a mean of 20.3 months (2-78), and distant relapse was seen in 45%, after a mean of 13.4 months (5-196). Mean Disease-free survival was 14.9 months, and overall 5-year-survival 43.5%. Amputation rate at 5 years was 24%. Conclusions: TM-ILP is a conservative treatment with a high complications rate, but it can be successful even for the most severe STS of extremities. As a consequence the limb can be spared from amputation or debilitating surgery on the long term in about 75% of patients
Resumo:
BACKGROUND: In an experimental setting, the performance of the LifeBox, a new portable extracorporeal membrane oxygenator (ECMO) system suitable for patient transport, is presented. Standard rectilinear percutaneous cannulae are normally employed for this purpose, but have limited flow and pressure delivery due to their rigid structure. Therefore, we aimed to determine the potential for flow increase by using self-expanding venous cannulae. METHODS: Veno-arterial bypass was established in three pigs (40.6+/-5.1 kg). The venous line of the cardiopulmonary bypass was established by cannulation of the external jugular vein. The arterial side of the circulation was secured by cannulation of the common carotid artery. Two different venous cannulae (SmartCanula 18/36F 430mm and Biomedicus 19F) were examined for their functional integrity when used in conjunction with the centrifugal pump (500-3000 RPM) of the LifeBox system. RESULTS: At 1500, 2000, 2500, and 3000 RPM, the blood flow increased steadily for each cannula, but remained higher in the self-expanding cannula. That is, the 19F rectilinear cannula achieved a blood flow of 0.93+/-0.14, 1.47+/-0.37, 1.9+/-0.68, and 1.5+/-0.9 l/min, respectively, and the 18/36F self-expanding cannula achieved 1.1+/-0.1, 1.9+/-0.33, 2.8+/-0.39 and 3.66+/-0.52 l/min. However, when tested for venous line pressure, the standard venous cannula achieved -29+/-10.7mmHg while the self-expanding cannula achieved -13.6 +/-4.3mmHg at 1500 RMP. As the RPM increased from 2500 to 3000, the venous line pressure accounted for -141.9+/-20 and -98+/-7.3mmHg for the 19F rectilinear cannula and -30.6+/-6.4 and -45+/-11.6mmHg for the self-expanding cannula. CONCLUSION: The self-expanding cannula exhibited superior venous drainage ability when compared to the performance of the standard rectilinear cannula with the use of the LifeBox. The flow rate achieved was approximately 40% greater than the standard drainage device, with a maximal pump flow recorded at 4.3l/min.
Resumo:
Selostus: Muutospaineet ja muutosvastarinta: kuluttajien suhtautuminen ravitsemuksellisesti muunnettuihin elintarvikkeisiin
Resumo:
P>Aim: To determine the effects of imperfect adherence (i.e. occasionally missing prescribed doses), and the influence of rate of loss of antihypertensive effect during treatment interruption, on the predicted clinical effectiveness of antihypertensive drugs in reducing mean systolic blood pressure (SBP) and cardiovascular disease (CVD) risk.Method:The effects of imperfect adherence to antihypertensive treatment regimens were estimated using published patterns of missed doses, and taking into account the rate of loss of antihypertensive effect when doses are missed (loss of BP reduction in mmHg/day; the off-rate), which varies between drugs. Outcome measures were the predicted mean SBP reduction and CVD risk, determined from the Framingham Risk Equation for CVD.Results:In patients taking 75% of prescribed doses (typical of clinical practice), only long-acting drugs with an off-rate of similar to 1 mmHg/day were predicted to maintain almost the full mean SBP-lowering effect throughout the modelled period. In such patients, using shorter-acting drugs (e.g. an off-rate of similar to 5-6 mmHg/day) was predicted to lead to a clinically relevant loss of mean SBP reduction of > 2 mmHg. This change also influenced the predicted CVD risk reduction; in patients with a baseline 10-year CVD risk of 27.0% and who were taking 75% of prescribed doses, a difference in off-rate from 1 to 5 mmHg/day led to a predicted 0.5% absolute increase in 10-year CVD risk.Conclusions:In patients who occasionally miss doses of antihypertensives, modest differences in the rate of loss of antihypertensive effect following treatment interruption may have a clinically relevant impact on SBP reduction and CVD risk. While clinicians must make every effort to counsel and encourage each of their patients to adhere to their prescribed medication, it may also be prudent to prescribe drugs with a low off-rate to mitigate the potential consequences of missing doses.
Resumo:
Plutonium and americium are radionuclides particularly difficult to measure in environmental samples because they are alpha-emitters and therefore necessitate a careful separation before any measurement, either using radiometric methods or ICP-SMS. Recent developments in extraction chromatography resins such as Eichrom (R) TRU and TEVA have resolved many of the analytical problems but drawbacks such as low recovery and spectral interferences still occasionally occur. Here, we report on the use of the new Eichrom (R) DGA resin in association with TEVA resin and high pressure microwave acid leaching for the sequential determination of plutonium and americium in environmental samples. The method results in average recoveries of 83 +/- 15% for plutonium and 73 +/- 22% for americium (n = 60), and a less than 10% deviation from reference values of four IAEA reference materials and three samples from intercomparisons exercises. The method is also suitable for measuring Pu-239 in water samples at the mu Bq/l level, if ICP-SMS is used for the measurement.