934 resultados para paired comparisons


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main properties of strangelets, namely their energy per baryon, radius and electric charge, are studied in the unpaired magnetized strange quark matter (MSQM) and paired magnetized colour flavour locked (MCFL) phases. Temperature effects are taken into account in order to study their stability compared to the Fe-56 isotope and nonmagnetized strangelets within the framework of the MIT bag model. We conclude that the presence of a magnetic field tends to stabilize the strangelets more, even when temperature is considered. It is also shown that MCFL strangelets are more stable than ordinary MSQM strangelets for typical gap values of the order of O(100) MeV. A distinctive feature in the detection of strangelets either in cosmic rays or in heavy-ion collider experiments could be their electric charge. We find that the electric charge is modified in the presence of the magnetic field, leading to higher (lower) charge values for MSQM (MCFL) strangelets, when compared to the nonmagnetized case.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pretendeu-se verificar a influência de dois tipos de ligaduras no tempo de reacção dos peroniais, através de electromiografia de superfície, em atletas femininas de voleibol, com história de entorse e indicadores de instabilidade. Efectuou-se um estudo com uma amostra de 15 atletas. Seleccionaram-se as ligaduras elástica adesiva em heel-lock e kinesiotape com aplicação peronial e ligamentar, pela sua indicação de diminuição da instabilidade tíbio-társica. Utilizaram-se os testes paramétricos ANOVA de medidas repetidas e Teste t para amostras emparelhadas. Verificou-se que a aplicação da ligadura kinesiotape reduziu o tempo de reacção dos peroniais enquanto a ligadura elástica não exerceu influência sobre este.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada à Escola Superior de Educação de Lisboa no âmbito do mestrado em Educação Especial

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Systematic review to identify the factors associated to the quality of life (QOL) of the caregivers of people with aphasia (PWA). Methods: Studies were searched using Medline, Pubmed, Cochrane Library, CINAHL, PsycINFO and Web of Science databases. Peer-reviewed papers that studied the QOL of PWA’s caregivers or the consequences of aphasia in caregivers’ life were included. Findings were extracted from the studies that met the inclusion criteria. Results: No data is available reporting particularly the QOL of PWA caregivers’ or their QOL predictors. Nevertheless, it was possible to extract aspects related to QOL from the studies that report the consequences of aphasia, and life changes in PWA’s caregivers. Nine (9) studies including PWA’s caregivers were found, but only 5 reported data separately on them. Methodological heterogeneity impedes cross-study comparisons, although some considerations can be made. PWA’s caregivers reported life changes such as: loss of freedom; social isolation; new responsibilities; anxiety; emotional loneliness; need for support and respite. Conclusions: Changes in social relationships, in emotional status, increased burden and need for support and respite were experienced by PWA’s caregivers. Stroke QOL studies need to include PWA caregivers’ and report separately on them. Further research is needed in this area in order to determine their QOL predictors and identify what interventions and referrals better suit their needs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years Ionic Liquids (ILs) are being applied in life sciences. ILs are being produce with active pharmaceutical drugs (API) as they can reduce polymorphism and drug solubility problems [1] Also ILs are being applied as a drug delivery device in innovative therapies What is appealing in ILs is the ILs building up platform, the counter-ion can be carefully chosen in order to avoid undesirable side effects or to give innovative therapies in which two active ions are paired. This work shows ILs based on ampicillin (an anti-bacterial agent) and ILs based on Amphotericin B. Also we show studies that indicate that ILs based on Ampicillin could reverse resistance in some bacteria. The ILs produced in this work were synthetized by the neutralization method described in Ferraz et. al. [2] Ampicillin anion was combined with the following organic cations 1-ethyl-3-methylimidazolium, [EMIM]; 1-hydroxy-ethyl-3-methylimidazolium, [C2OHMIM]; choline, [cholin]; tetraethylammonium, [TEA]; cetylpyridinium, [C16pyr] and trihexyltetradecylphosphonium, [P6,6,6,14]. Amphotericin B was combined with [C16pyr], [cholin] and 1-metohyethyl-3-methylimidazolium, [C3OMIM]. The ILs-APIs based on ampicillin[2] were tested against sensitive Gram-negative bacteria Escherichia coli ATCC 25922 and Klebsiella pneumonia (clinical isolated), as well as on Gram positive Staphylococcus Aureus ATCC 25923, Staphylococcus epidermidis and Enterococcus faecalis. The arising resistance developed by bacteria to antibiotics is a serious public health threat and needs new and urgent measures. We study the bacterial activity of these compounds against a panel of resistant bacteria (clinical isolated strains): E. coli CTX M9, E. coli TEM CTX M9, E. coli TEM1, E. coli CTX M2, E. coli AmpC Mox2. In this work we demonstrate that is possible to produce ILs from anti-bacterial and anti-fungal compounds. We show here that the new ILs can reverse the bacteria resistance. With the careful choice of the organic cation, it is possible to create important biological and physic-chemical properties. This work also shows that the ion-pair is fundamental in ampicillin mechanism of action.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A replicate evaluation of increased micronucleus (MN) frequencies in peripheral lymphocytes of workers occupationally exposed to formaldehyde (FA) was undertaken to verify the observed effect and to determine scoring variability. May–Grünwald–Giemsa-stained slides were obtained from a previously performed cytokinesis-block micronucleus test (CBMNT) with 56 workers in anatomy and pathology laboratories and 85 controls. The first evaluation by one scorer (scorer 1) had led to a highly significant difference between workers and controls (3.96 vs 0.81 MN per 1000 cells). The slides were coded before re-evaluation and the code was broken after the complete re-evaluation of the study. A total of 1000 binucleated cells (BNC) were analysed per subject and the frequency of MN (in ‰) was determined. Slides were distributed equally and randomly between two scorers, so that the scorers had no knowledge of the exposure status. Scorer 2 (32 exposed, 36 controls) measured increased MN frequencies in exposed workers (9.88 vs 6.81). Statistical analysis with the two-sample Wilcoxon test indicated that this difference was not significant (p = 0.17). Scorer 3 (20 exposed, 46 controls) obtained a similar result, but slightly higher values for the comparison of exposed and controls (19.0 vs 12.89; p = 0.089). Combining the results of the two scorers (13.38 vs 10.22), a significant difference between exposed and controls (p = 0.028) was obtained when the stratified Wilcoxon test with the scorers as strata was applied. Interestingly, the re-evaluation of the slides led to clearly higher MN frequencies for exposed and controls compared with the first evaluation. Bland–Altman plots indicated that the agreement between the measurements of the different scorers was very poor, as shown by mean differences of 5.9 between scorer 1 and scorer 2 and 13.0 between scorer 1 and scorer 3. Calculation of the intra-class correlation coefficient (ICC) revealed that all scorer comparisons in this study were far from acceptable for the reliability of this assay. Possible implications for the use of the CBMNT in human biomonitoring studies are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Copyright © 2013 John Wiley & Sons Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado, Estudos Integrados dos Oceanos, 20 de Março de 2014, Universidade dos Açores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Copyright © 2014 The Authors. Methods in Ecology and Evolution © 2014 British Ecological Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To determine the prevalence of reagent serology for suspected acute toxoplasmosis in pregnant women and to describe clinical, laboratory and therapeutic profiles of mothers and their children. METHODS: A retrospective study was conducted with IgM-anti-Toxoplasma gondii-reagent pregnant women and their children who attended the public health system in the state of Paraná, Southern Brazil, from January 2001 to December 2003. Information were obtained from clinical, laboratory (ELISA IgM/IgG) and ultrasonographic data and from interviews with the mothers. To test the homogeneity of the IgM indices in relation to the treatment used, the Pearson's Chi-square test was applied. Comparisons were considered significant at a 5% level. RESULTS: Two hundred and ninety (1.0%) cases of suspected IgM-reagent infection were documented, with a prevalence of 10.7 IgM-reagent women per 1,000 births. Prenatal care started within the first 12 weeks for 214/290; 146/204 were asymptomatic. Frequent complaints included headaches, visual disturbance and myalgia. Ultrasonography revealed abnormalities in 13 of 204 pregnancies. Chemoprophylaxis was administered to 112/227; a single ELISA test supported most decisions to begin treatment. Pregnant women with IgM indices =2.000 tended to be treated more often. Among exposed children, 44/208 were serologically followed up and all were IgG-reagent, and three IgM-reagent cases showed clinical symptoms. CONCLUSIONS: The existence of pregnant women with laboratorially suspected acute toxoplasmosis who were not properly followed up, and of fetuses that were not adequately monitored, shows that basic aspects of the prenatal care are not being systematically observed. There is need of implementing a surveillance system of pregnant women and their children exposed to T. gondii.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Copyright © Springer-Verlag Berlin Heidelberg and AWI 2014.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Geotécnica e Geoambiente

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective - To describe and validate the simulation of the basic features of GE Millennium MG gamma camera using the GATE Monte Carlo platform. Material and methods - Crystal size and thickness, parallel-hole collimation and a realistic energy acquisition window were simulated in the GATE platform. GATE results were compared to experimental data in the following imaging conditions: a point source of 99mTc at different positions during static imaging and tomographic acquisitions using two different energy windows. The accuracy between the events expected and detected by simulation was obtained with the Mann–Whitney–Wilcoxon test. Comparisons were made regarding the measurement of sensitivity and spatial resolution, static and tomographic. Simulated and experimental spatial resolutions for tomographic data were compared with the Kruskal–Wallis test to assess simulation accuracy for this parameter. Results - There was good agreement between simulated and experimental data. The number of decays expected when compared with the number of decays registered, showed small deviation (≤0.007%). The sensitivity comparisons between static acquisitions for different distances from source to collimator (1, 5, 10, 20, 30cm) with energy windows of 126–154 keV and 130–158 keV showed differences of 4.4%, 5.5%, 4.2%, 5.5%, 4.5% and 5.4%, 6.3%, 6.3%, 5.8%, 5.3%, respectively. For the tomographic acquisitions, the mean differences were 7.5% and 9.8% for the energy window 126–154 keV and 130–158 keV. Comparison of simulated and experimental spatial resolutions for tomographic data showed no statistically significant differences with 95% confidence interval. Conclusions - Adequate simulation of the system basic features using GATE Monte Carlo simulation platform was achieved and validated.