925 resultados para incompleteness and inconsistency detection
Resumo:
The main goal of this work was to develop a simple analytical method for quantification of glycerol based on the electrocatalytic oxidation of glycerol on the copper surface adapted in a flow injection system. Under optimal experimental conditions, the peak current response increases linearly with glycerol concentration over the range 60-3200 mg kg(-1) (equivalent to 3-160 mg L(-1) in solution). The repeatability of the electrode response in the flow injection analysis (FIA) configuration was evaluated as 5% (n = 10), and the detection limit of the method was estimated to be 5 mg kg(-1) in biodiesel (equivalent to 250 mu g L(-1) in solution) (S/N = 3). The sample throughput under optimised conditions was estimated to be 90 h(-1). Different types of biodiesel samples (B100), as in the types of vegetable oils or animal fats used to produce the fuels, were analysed (seven samples). The only sample pre-treatment used was an extraction of glycerol from the biodiesel sample containing a ratio of 5 mL of water to 250 mg of biodiesel. The proposed method improves the analytical parameters obtained by other electroanalytical methods for quantification of glycerol in biodiesel samples, and its accuracy was evaluated using a spike-and-recovery assay, where all the biodiesel samples used obtained admissible values according to the Association of Official Analytical Chemists. Crown Copyright (C) 2011 Published by Elsevier Ltd. All rights reserved.
Resumo:
Purpose: The methodology currently used for interpretation of the cornea and anterior segment tomography for the diagnosis of corneal ectasia and its susceptibility. Methods: Description of the methodology and clinical interpretation of corneal and anterior segment tomography indexes; report of three cases demonstrating the importance of this new diagnostic tool (Pentacam HR (R)) in ophthalmological practice. Conclusion: The use of corneal and anterior segment tomography seems to be an effective method to increase the sensitivity and specificity for the diagnosis and early detection of corneal ectasia.
Resumo:
Most of the antiretroviral (ARV) studies in Brazil have been reported in treatment-experienced and naive patients rather than in the setting of treatment interruption (TI). In this study, we analysed reasons given for TI and resistance mutations occurring in 150 HIV-1-infected patients who underwent TI. Of the patients analysed, 110 (73.3%) experienced TI following medical advice, while the remaining patients stopped antiretroviral therapy (ART) of their own accord. The main justifications for TI were: ARV-related toxicities (38.7%), good laboratory parameters (30%) and poor adherence (20%). DNA sequencing of the partial pol gene was successful in 137 (91.3%) patients, of whom 38 (27.7%) presented mutations conferring ARV resistance. A higher viral load prior to TI correlated with drug resistance (P < 0.05). Our results demonstrate that there are diverse rationales for TI and that detection of resistant strains during TI most likely indicates a fitter virus than the wild type. High viral loads coupled with unprotected sex in this group could increase the likelihood of transmission of drug-resistant virus. Thus, treating physicians should be alerted to this problem when the use of ARVs is interrupted.
Resumo:
We report the discovery of two low-mass companions to the young A0V star HD 1160 at projected separations of 81 +/- 5 AU (HD 1160 B) and 533 +/- 25 AU (HD 1160 C) by the Gemini NICI Planet-Finding Campaign. Very Large Telescope images of the system taken over a decade for the purpose of using HD 1160 A as a photometric calibrator confirm that both companions are physically associated. By comparing the system to members of young moving groups and open clusters with well-established ages, we estimate an age of 50(-40)(+50) Myr for HD 1160 ABC. While the UVW motion of the system does not match any known moving group, the small magnitude of the space velocity is consistent with youth. Near-IR spectroscopy shows HD 1160 C to be an M3.5 +/- 0.5 star with an estimated mass of 0.22(-0.04)(+0.03) M-circle dot, while NIR photometry of HD 1160 B suggests a brown dwarf with a mass of 33(-9)(+12) M-Jup. The very small mass ratio (0.014) between the A and B components of the system is rare for A star binaries, and would represent a planetary-mass companion were HD 1160 A to be slightly less massive than the Sun.
Resumo:
In this manuscript, an automatic setup for screening of microcystins in surface waters by employing photometric detection is described. Microcystins are toxins delivered by cyanobacteria within an aquatic environment, which have been considered strongly poisonous for humans. For that reason, the World Health Organization (WHO) has proposed a provisional guideline value for drinking water of 1 mu g L-1. In this work, we developed an automated equipment setup, which allows the screening of water for concentration of microcystins below 0.1 mu g V. The photometric method was based on the enzyme-linked immunosorbent assay (ELISA) and the analytical signal was monitored at 458 nm using a homemade LED-based photometer. The proposed system was employed for the detection of microcystins in rivers and lakes waters. Accuracy was assessed by processing samples using a reference method and applying the paired t-test between results. No significant difference at the 95% confidence level was observed. Other useful features including a linear response ranging from 0.05 up to 2.00 mu g L-1 (R-2 =0.999) and a detection limit of 0.03 mu g L-1 microcystins were achieved. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Hydroethanolic extracts of C. langsdorffii leaves have therapeutic potential. This work reports a validated chromatographic method for the quantification of polar compounds in the hydroethanolic extract of C. langsdorffii leaves. A reliable HPLC method was developed using two monolithic columns linked in series (100 x 4.6 mm - C-18), with nonlinear gradient elution, and UV detection set at 257 nm. A procedure for the extraction of flavonols was also developed, which involved the use of 70% aqueous ethanol and the addition of benzophenone as the internal standard. The developed method led to a good detection response as the values for linearity were between 10.3 and 1000 mu g/mL, and those for recovery between 84.2 and 111.1%. The detection limit ranged from 0.02 to 1.70 mu g/mL and the quantitation limit from 0.07 to 5.1 mu g/mL, with a maximum RSD of 5.24%. Five compounds, rutin, quercetin-3-O-alpha-L-rhamnopyranoside, kaempferol-3-O-alpha-L-rhamnopyranoside, quercetin and kaempferol, were quantified. This method could, therefore, be used for the quality control of hydroethanolic extracts of Copaifera leaves and their cosmetic and pharmaceutical products.
Resumo:
Foodborne diseases represent operational risks in industrial restaurants. We described an outbreak of nine clustered cases of acute illness resembling acute toxoplasmosis in an industrial plant with 2300 employees. These patients and another 36 similar asymptomatic employees were diagnosed with anti-T. gondii IgG titer and avidity by ELISA. We excluded 14 patients based on high IgG avidity and chronic toxoplasmosis: 13 from controls and one from acute disease other than T. gondii infection. We also identified another three asymptomatic employees with T.gondii acute infection and also anti-T. gondii IgM positive as remaining acute cases. Case control study was conducted by interview in 11 acute infections and 20 negative controls. The ingestion of green vegetables, but not meat or water, was observed to be associated with the incidence of acute disease. These data reinforce the importance of sanitation control in industrial restaurants and also demonstrate the need for improvement in quality control regarding vegetables at risk for T. gondii oocyst contamination. We emphasized the accurate diagnosis of indexed cases and the detection of asymptomatic infections to determine the extent of the toxoplasmosis outbreak.
Resumo:
Foodborne diseases represent operational risks in industrial restaurants. We described an outbreak of nine clustered cases of acute illness resembling acute toxoplasmosis in an industrial plant with 2300 employees. These patients and another 36 similar asymptomatic employees were diagnosed with anti-T. gondii IgG titer and avidity by ELISA. We excluded 14 patients based on high IgG avidity and chronic toxoplasmosis: 13 from controls and one from acute disease other than T. gondii infection. We also identified another three asymptomatic employees with T.gondii acute infection and also anti-T. gondii IgM positive as remaining acute cases. Case control study was conducted by interview in 11 acute infections and 20 negative controls. The ingestion of green vegetables, but not meat or water, was observed to be associated with the incidence of acute disease. These data reinforce the importance of sanitation control in industrial restaurants and also demonstrate the need for improvement in quality control regarding vegetables at risk for T. gondii oocyst contamination. We emphasized the accurate diagnosis of indexed cases and the detection of asymptomatic infections to determine the extent of the toxoplasmosis outbreak.
Resumo:
OBJECTIVE: The aim of the current study was to monitor the migration of superparamagnetic iron oxide nanoparticle (SPION)-labeled C6 cells, which were used to induce glioblastoma tumor growth in an animal model, over time using magnetic resonance imaging (MRI), with the goal of aiding in tumor prognosis and therapy. METHODS: Two groups of male Wistar rats were used for the tumor induction model. In the first group (n=3), the tumors were induced via the injection of SPION-labeled C6 cells. In the second group (n=3), the tumors were induced via the injection of unlabeled C6 cells. Prussian Blue staining was performed to analyze the SPION distribution within the C6 cells in vitro. Tumor-inducing C6 cells were injected into the right frontal cortex, and subsequent tumor monitoring and SPION detection were performed using T2- and T2*-weighted MRI at a 2T field strength. In addition, cancerous tissue was histologically analyzed after performing the MRI studies. RESULTS: The in vitro qualitative evaluation demonstrated adequate distribution and satisfactory cell labeling of the SPIONs. At 14 or 21 days after C6 injection, a SPION-induced T2- and T2*-weighted MRI signal reduction was observed within the lesion located in the left frontal lobe on parasagittal topography. Moreover, histological staining of the tumor tissue with Prussian Blue revealed a broad distribution of SPIONs within the C6 cells. CONCLUSION: MRI analyses exhibit potential for monitoring the tumor growth of C6 cells efficiently labeled with SPIONs.
Resumo:
The development of microlectronic lab-on-a-chip devices (LOACs) can now be pursued thanks to the continous advances in silicon technology. LOACs are miniaturized devices whose aim is to perform in a more efficient way specific chemical or biological analysis protocols which are usually carried out with traditional laboratory equipment. In this application area, CMOS technology has the potential to integrate LOAC functionalities for cell biology applications in single chips, e.g. sensors, actuators, signal conditioning and processing circuits. In this work, after a review of the state of the art, the development of a CMOS prototype chip for individual cell manipulation and detection based on dielectrophoresis will be presented. Issues related to the embedded optical and capacitive detection of cells will be discussed together with the main experimental results obtained in manipulation and detection of living cells and microparticles.
Resumo:
[ES]El proyecto contiene módulos de simulación, procesado de datos, mapeo y localización, desarrollados en C++ utilizando ROS (Robot Operating System) y PCL (Point Cloud Library). Ha sido desarrollado bajo el proyecto de robótica submarina AVORA.Se han caracterizado el vehículo y el sensor, y se han analizado diferentes tecnologías de sensores y mapeo. Los datos pasan por tres etapas: Conversión a nube de puntos, filtrado por umbral, eliminación de puntos espureos y, opcionalmente, detección de formas. Estos datos son utilizados para construir un mapa de superficie multinivel. La otra herramienta desarrollada es un algoritmo de Punto más Cercano Iterativo (ICP) modificado, que tiene en cuenta el modo de funcionamiento del sonar de imagen utilizado.
Resumo:
[EN]This paper describes a low-cost system that allows the user to visualize different glasses models in live video. The user can also move the glasses to adjust its position on the face. The system, which runs at 9.5 frames/s on general-purpose hardware, has a homeostatic module that keeps image parameters controlled. This is achieved by using a camera with motorized zoom, iris, white balance, etc. This feature can be specially useful in environments with changing illumination and shadows, like in an optical shop. The system also includes a face and eye detection module and a glasses management module.
Resumo:
The aminothiols are critical cellular components that play numerous and important roles in metabolism as key extracellular reducing agents, critical substrates for proteins synthesis and detoxificants of free radicals and peroxides. Because altered thiols levels in body fluids are linked to specific pathological conditions, their measurement is thus considered very important. One method to determine these compounds is the capillary electrophoresis, a technique that involves the separation of charged molecules on the basis of their movement under the influence of an applied electric field. The instrument used in this work is equipped with an amperometric detector recording the current of the thiols oxidized at the end of the capillary at a BDD electrode. The aim of this work is to find a valid method for the separations of the aminothiols analyzed, in terms of capillary coating and experimental conditions. In order to find an alternative and less expensive electrode than BDD and to increase sensitivity for the detection of the thiols, a modified electrode consisting in a carbon paste electrode containing Cobalt-phthalocyanine has been studied. In this electrode Cobalt-phthalocyanine works as electrocatalyst to enhance the oxidation reaction, meanwhile the graphite acts as conductive mean. This kind of electrode shows great sensibility and low detection limits for the thiols that have a free thiolic group, but it is not sensible to disulfides. The analysis of human plasma point out that the best method found for the capillary electrophoresis is not useful for the detection of aminothiols in a healthy person, because the very low concentrations in which they are present.
Resumo:
During the previous 10 years, global R&D expenditure in the pharmaceuticals and biotechnology sector has steadily increased, without a corresponding increase in output of new medicines. To address this situation, the biopharmaceutical industry's greatest need is to predict the failures at the earliest possible stage of the drug development process. A major key to reducing failures in drug screenings is the development and use of preclinical models that are more predictive of efficacy and safety in clinical trials. Further, relevant animal models are needed to allow a wider testing of novel hypotheses. Key to this is the developing, refining, and validating of complex animal models that directly link therapeutic targets to the phenotype of disease, allowing earlier prediction of human response to medicines and identification of safety biomarkers. Morehover, well-designed animal studies are essential to bridge the gap between test in cell cultures and people. Zebrafish is emerging, complementary to other models, as a powerful system for cancer studies and drugs discovery. We aim to investigate this research area designing a new preclinical cancer model based on the in vivo imaging of zebrafish embryogenesis. Technological advances in imaging have made it feasible to acquire nondestructive in vivo images of fluorescently labeled structures, such as cell nuclei and membranes, throughout early Zebrafishsh embryogenesis. This In vivo image-based investigation provides measurements for a large number of features at cellular level and events including nuclei movements, cells counting, and mitosis detection, thereby enabling the estimation of more significant parameters such as proliferation rate, highly relevant for investigating anticancer drug effects. In this work, we designed a standardized procedure for accessing drug activity at the cellular level in live zebrafish embryos. The procedure includes methodologies and tools that combine imaging and fully automated measurements of embryonic cell proliferation rate. We achieved proliferation rate estimation through the automatic classification and density measurement of epithelial enveloping layer and deep layer cells. Automatic embryonic cells classification provides the bases to measure the variability of relevant parameters, such as cell density, in different classes of cells and is finalized to the estimation of efficacy and selectivity of anticancer drugs. Through these methodologies we were able to evaluate and to measure in vivo the therapeutic potential and overall toxicity of Dbait and Irinotecan anticancer molecules. Results achieved on these anticancer molecules are presented and discussed; furthermore, extensive accuracy measurements are provided to investigate the robustness of the proposed procedure. Altogether, these observations indicate that zebrafish embryo can be a useful and cost-effective alternative to some mammalian models for the preclinical test of anticancer drugs and it might also provides, in the near future, opportunities to accelerate the process of drug discovery.
Resumo:
ZusammenfassungDie Resonanzionisationsmassenspektrometrie (RIMS) verbindet hohe Elementselektivität mit guter Nachweiseffizienz. Aufgrund dieser Eigenschaften ist die Methode für Ultraspurenanalyse und Untersuchungen an seltenen oder schwer handhabbaren Elementen gut geeignet. Für RIMS werden neutrale Atome mit monochromatischem Laserlicht ein- oder mehrfach resonant auf energetisch hoch liegende Niveaus angeregt und anschließend durch einen weiteren Laserstrahl oder durch ein elektrisches Feld ionisiert. Die Photoionen werden in einem Massenspektrometer massenselektiv registriert.Ein Beispiel für die Anwendung von RIMS ist die präzise Bestimmung der Ionisationsenergie als fundamentale physikalisch-chemische Eigenschaft eines bestimmten Elements; insbesondere bei den Actinoiden ist die Kenntnis der Ionisationsenergie von Interesse, da es dort bis zur Anwendung der laser-massenspektroskopischer Methode nur wenige experimentelle Daten gab. Die Bestimmung der Ionisationsenergie erfolgt durch die Methode der Photoionisation im elektrischen Feld gemäß dem klassischen Sattelpunktsmodell. Im Experiment werden neutrale Atome in einem Atomstrahl mittels Laserlicht zunächst resonant angeregt. Die angeregten Atome befinden sich in einem äußeren, statischen elektrischen Feld und werden durch einen weiteren Laserstrahl, dessen Wellenlänge durchgestimmt wird, ionisiert. Das Überschreiten der Laserschwelle macht sich durch einen starken Anstieg im Ionensignal bemerkbar. Man führt diese Messung bei verschiedenen elektrischen Feldstärken durch und erhält bei Auftragen der Ionisationsschwellen gegen die Wurzel der elektrischen Feldstärke durch Extrapolation auf die Feldstärke Null die Ionisationsenergie.Im Rahmen dieser Arbeit wurde die Ionisationsenergie von Actinium erstmalig zu 43398(3) cm-1 º 5,3807(4) eV experimentell bestimmt. Dazu wurden Actiniumatome zunächst einstufig resonant mit einem Laser mit einer Wellenlänge von 388,67 nm auf einen Zustand bei 25729,03 cm-1 angeregt und anschließend mit Laserlicht mit einer Wellenlänge von ca. 568 nm ionisiert. Damit sind die Ionisationsenergien aller Actinoiden bis einschließlich Einsteinium mit Ausnahme von Protactinium bekannt. Als Atomstrahlquelle wird ein spezielles 'Sandwichfilament' benutzt, bei dem das Actinoid als Hydroxid auf eine Tantalfolie aufgebracht und mit einer reduzierenden Deckschicht überzogen wird. Das Actinoid dampft bei Heizen dieser Anordnung atomar ab. Bei den schwereren Actinoiden wurde Titan als Deckschicht verwendet. Um einen Actiniumatomstrahl zu erzeugen, wurde aufgrund der hohen Abdampftemperaturen statt Titan erstmals Zirkonium eingesetzt. Bei Protactinium wurde Thorium, welches noch stärkere Reduktionseigenschaften aufweist, als Deckmaterial eingesetzt. Trotzdem gelang es mit der 'Sandwichtechnik' nicht, einen Protactiniumatomstrahl zu erzeugen. In der Flugzeitapparatur wurde lediglich ein Protactinium-monoxidionensignal detektiert. Um ein erst seit kurzem verfügbares Fest-körperlasersystem zu explorieren, wurden zusätzlich noch die bekannten Ionisations-ener-gien von Gadolinium und Plutonium erneut bestimmt. Die gemessenen Werte stimmen mit Literaturdaten gut überein.Ferner wurde noch ein bestehender Trennungsgang für Plutonium aus Umweltproben auf die Matrices Meerwasser und Hausstaub angepasst und für die Bestimmung von Plutonium und dessen Isotopenzusammensetzung in verschiedenen Probenreihen mittels RIMS eingesetzt. Der modifizierte Trennungsgang ermöglicht das schnelle Aufarbeiten von großen Probenmengen für Reihenuntersuchungen von Plutoniumkontaminationen. Die ermittelten Gehalten an 239Pu lagen zwischen 8,2*107 Atome pro 10 l Meerwasserprobe und 1,7*109Atome pro Gramm Staubprobe.