945 resultados para gait, analysis, treadmill, COM, vertical, medio, lateral, displacement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentada ao Instituto Superior de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria, sob orientação do Mestre Paulino Silva

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biomechanical gait parameters—ground reaction forces (GRFs) and plantar pressures—during load carriage of young adults were compared at a low gait cadence and a high gait cadence. Differences between load carriage and normal walking during both gait cadences were also assessed. A force plate and an in-shoe plantar pressure system were used to assess 60 adults while they were walking either normally (unloaded condition) or wearing a backpack (loaded condition) at low (70 steps per minute) and high gait cadences (120 steps per minute). GRF and plantar pressure peaks were scaled to body weight (or body weight plus backpack weight). With medium to high effect sizes we found greater anterior-posterior and vertical GRFs and greater plantar pressure peaks in the rearfoot, forefoot and hallux when the participants walked carrying a backpack at high gait cadences compared to walking at low gait cadences. Differences between loaded and unloaded conditions in both gait cadences were also observed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A dissertação em apreço resultou da necessidade em otimizar os recursos técnicos, mas sobretudo humanos, afetos às verificações de instrumentos de medição, no âmbito do Controlo Metrológico Legal. Estas verificações, realizadas nos termos do cumprimento das competências outrora atribuídas à Direção de Serviços da Qualidade da então Direção Regional da Economia do Norte, eram operacionalizadas pela Divisão da Qualidade e Licenciamento, na altura dirigida pelo subscritor da presente tese, nomeadamente no que respeita aos ensaios efetuados, em laboratório, a manómetros analógicos. O objetivo principal do trabalho foi alcançado mediante o desenvolvimento de um automatismo, materializado pela construção de um protótipo, cuja aplicação ao comparador de pressão múltiplo, dantes em utilização, permitiria realizar a leitura da indicação de cada manómetro analógico através de técnicas de processamento de imagem, função esta tradicionalmente efetuada manualmente por um operador especializado. As metodologias de comando, controlo e medição desse automatismo foram realizadas através de um algoritmo implementado no software LabVIEW® da National Intruments, particularmente no que respeita ao referido processamento das imagens adquiridas por uma câmara de vídeo USB. A interface com o hardware foi concretizada recorrendo a um módulo de Aquisição de Dados Multifuncional (DAQ) USB-6212, do mesmo fabricante. Para o posicionamento horizontal e vertical da câmara de vídeo USB, recorreu-se a guias lineares acionadas por motores de passo, sendo que estes dispositivos foram igualmente empregues no acionamento do comparador de pressão. Por último, procedeu-se à aquisição digital da leitura do padrão, recorrendo à respetiva virtualização, bem como a uma aplicação desenvolvida neste projeto, designada appMAN, destinada à gestão global do referido automatismo, nomeadamente no que se refere ao cálculo do resultado da medição, erro e incerteza associada, e emissão dos respetivos documentos comprovativos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O presente projeto foi realizado no âmbito da unidade curricular Dissertação/Estágio/Projeto, e desenvolve um estudo sobre as estruturas porticadas de sinalização vertical em Autoestradas, ao nível da estrutura metálica e das fundações, com o objetivo de analisar três casos diferentes com características distintas. Dois dos casos em estudo são modelos comuns que se encontram facilmente nas autoestradas. O terceiro tem uma configuração diferente, mais gravoso que o habitual. Com estes três casos obtém-se um estudo completo e abrangente deste tipo de estrutura porticada. Ao longo do projeto é seguida a norma EC3 (Eurocódigo 3 – Projeto de estruturas de aço). Dimensionaram-se as estruturas utilizando secções tubulares, mas é também realizado o dimensionamento de uma solução estrutural alternativa recorrendo a perfis laminados I ou H. As estruturas foram modeladas com recurso ao software de cálculo Autodesk Robot Structural Analysis Professional, obtendo-se os esforços e deformações nos vários pontos da estrutura, que permitem realizar o dimensionamento manual das secções dos perfis estruturais, chumbadouros, chapas de fundação e fundações propriamente ditas. Na parte final do projeto apresenta-se uma apreciação global do mesmo, conclusões gerais sobre os resultados obtidos e possíveis desenvolvimentos futuros.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUMO - A qualidade e segurança são pilares essenciais dos sistemas de saúde modernos. A sua monitorização e avaliação tem como primeiro passo o conhecimento da realidade no que se refere aos eventos adversos que afetam os utentes. Existem diversas metodologias de medição de eventos adversos. A revisão de processos clínicos, apesar de constituir o padrão de ouro, não permite, ao contrário da análise dos dados administrativos, avaliar de forma abrangente, os episódios de internamento. Esta metodologia a partir de dados recolhidos rotineiramente em inúmeros países, como Portugal, apresenta porém diversas limitações, para as quais têm sido instituídas soluções tais como a sinalização do momento de aquisição do diagnóstico, que pela recente instituição não foi utilizada neste trabalho. Num hospital do Sistema nacional de saúde em Portugal, pela análise dos dados administrativos, determinou-se nos episódios de internamento cirúrgico uma incidência de 2,5% de eventos adversos. Comprovou-se a relação de idade, sexo masculino e admissão urgente com a sua ocorrência. Os doentes que sofreram um evento adverso apresentaram uma probabilidade de óbito bastante superior (odds ratio 12,2) e apresentaram tempos de internamento médio prolongados em cerca de vinte dias. Estes dados não são contudo ajustados para o risco do doente e das intervenções a que são sujeitos. Se forem considerados os tempos de internamento das tabelas de GDH em Portugal, o prolongamento do internamento é de 8,4 dias. A avaliação dos custos adicionais, realizada pelos dias de internamento adicionais, está condicionada à questão metodológica atrás reportada, estimando-se implicações de 1,1% a 8,8% de dias de internamento, com custos de 1.000.000 a 8.600.000 Euros. Em Portugal a monitorização sistemática da ocorrência de eventos, e consequentemente das implicações para a saúde do doente e custos financeiros, não é ainda uma realidade. A implementação do código "presente na admissão" permitirá dar o passo seguinte na utilização dos dados administrativos na compreensão do fenómeno dos eventos adversos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUMO - Introdução: A integração vertical de cuidados surge em Portugal em 1999 com a criação da primeira Unidade Local de Saúde (ULS) em Matosinhos. Este modelo de gestão tem como principal objetivo reorganizar o sistema para responder de forma mais custo-efetiva às necessidades atuais. Objetivo: Analisar o impacto da criação das ULS nos custos do internamento hospitalar português. Metodologia: Para apurar o custo médio estimado por episódio de internamento hospitalar utilizou-se a metodologia dos Custos Estimados com base na Contabilidade Analítica. Contudo, não foram imputados custos por diária de internamento por centro de produção, mas apenas por doente saído em determinado hospital. Para efeitos de comparação dos modelos de gestão organizacionais consideraram-se variáveis demográficas e variáveis de produção. Resultados: Da análise global, os hospitais integrados em ULS apresentam um custo médio estimado por episódio de internamento inferior quando comparados com os restantes. Em 2004 os hospitais sem modelo de integração vertical de cuidados apresentam uma diferença de custos de aproximadamente 714,00€. No ano 2009, último ano em análise, esta diferença é mais ténue situando-se nos 232,00€ quando comparados com hospitais integrados em ULS. Discussão e Conclusão: Não existe uma tendência definida no que respeita à diferença de custos quando se comparam os diferentes modelos organizacionais. É importante que em estudos futuros se alargue a amostra ao total de prestadores e se aprofundem os fatores que influênciam os custos de internamento. A compreensão dos indicadores sociodemográficos, demora média, e produção realizada, numa ótica de custo efetividade e qualidade, permitirá resultados com menor grau de viés.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Several scores are commonly used to evaluate patients' postoperative satisfaction after lateral ankle ligament repair, including: AOFAS, FAAM, CAIT and CAIS. Comparing published studies in the literature is difficult, as the same patient can have markedly different results depending on which scoring system is used. The current study aims to address this gap in the literature by developing a system to compare these tests, to allow better analysis and comparison of published studies. Patients and methods: This is a retrospective cohort study of 47 patients following lateral ankle ligament repair using a modified Broström-Gould technique. All patients were operated between 2005 and 2010 by a single surgeon and followed the same post operative rehabilitation protocol. Six patients were excluded from the study because of concomitant surgery. Patients were assessed by an independent observer. We used the Pearson correlation coefficient to analyse the concordance of the scores, as well as scatter plots to assess the linear relationship between them. Results: A linear distribution between the scores was found when the results were analysed using scatter plots. We were thus able to use the Pearson correlation coefficient to evaluate the relationship between each of the different postoperative scores. The correlation was found to be above 0.5 in all cases except for the comparison between the CAIT and the FAAM for the activities of daily living (0.39). We were, therefore, able to compare the results obtained and assess the relative concordance of the scoring systems. The results showed that the more specific the scale is, the worst the score is and inversely. So the CAIT and the CAIS appeared to be more severe than the AOFAS and the FAAM measuring the activities of daily living. The sports subscale of the FAAM demonstrated intermediate results. Conclusion: This study outlines a system to compare different postoperative scores commonly used to evaluate outcome after ankle stabilization surgery. The impact of this study is that it makes comparison of published studies easier, even though they use a variety of different clinical scores, thus facilitating better outcome analysis of operative techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The determination of characteristic cardiac parameters, such as displacement, stress and strain distribution are essential for an understanding of the mechanics of the heart. The calculation of these parameters has been limited until recently by the use of idealised mathematical representations of biventricular geometries and by applying simple material laws. On the basis of 20 short axis heart slices and in consideration of linear and nonlinear material behaviour we have developed a FE model with about 100,000 degrees of freedom. Marching Cubes and Phong's incremental shading technique were used to visualise the three dimensional geometry. In a quasistatic FE analysis continuous distribution of regional stress and strain corresponding to the endsystolic state were calculated. Substantial regional variation of the Von Mises stress and the total strain energy were observed at all levels of the heart model. The results of both the linear elastic model and the model with a nonlinear material description (Mooney-Rivlin) were compared. While the stress distribution and peak stress values were found to be comparable, the displacement vectors obtained with the nonlinear model were generally higher in comparison with the linear elastic case indicating the need to include nonlinear effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human electrophysiological studies support a model whereby sensitivity to so-called illusory contour stimuli is first seen within the lateral occipital complex. A challenge to this model posits that the lateral occipital complex is a general site for crude region-based segmentation, based on findings of equivalent hemodynamic activations in the lateral occipital complex to illusory contour and so-called salient region stimuli, a stimulus class that lacks the classic bounding contours of illusory contours. Using high-density electrical mapping of visual evoked potentials, we show that early lateral occipital cortex activity is substantially stronger to illusory contour than to salient region stimuli, whereas later lateral occipital complex activity is stronger to salient region than to illusory contour stimuli. Our results suggest that equivalent hemodynamic activity to illusory contour and salient region stimuli probably reflects temporally integrated responses, a result of the poor temporal resolution of hemodynamic imaging. The temporal precision of visual evoked potentials is critical for establishing viable models of completion processes and visual scene analysis. We propose that crude spatial segmentation analyses, which are insensitive to illusory contours, occur first within dorsal visual regions, not the lateral occipital complex, and that initial illusory contour sensitivity is a function of the lateral occipital complex.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Se presentan en variaciones estacionales y se discuten las interrelaciones entre el medio ambiente y la productividad durante agosto de 1972 - junio 1973 en el área de 06° - 09°S, la cual es un importante centro de afloramiento. Este estudio forma parte de las investigaciones que se realizan en dicha área a través del proyecto OEA/ IMARPE. Las temperaturas en la superficie del mar se desarrollaron por encima del promedio hasta marzo de 1973, restableciéndose las condiciones oceanográficas en abril de ese año. En diciembre se observó un cambio brusco en las condiciones oceanográficas debido a la presencia de las aguas de la región ecuatorial las cuales avanzaron hasta Huarmey (10°S) en forma de una lengua costera con temperaturas de 23 - 25 °C, salinidades de 34.0 - 34.8‰, bajo contenido de nutrientes y pobre productividad, afectando la distribución y/o disponibilidad de la fauna marina. En la superficie del mar se halló la relación P: N: Si promedio de 1: 9.5: 8.3, lo cual hace pensar que los silicatos pueden llegar a ser limitantes en la producción fotosintética. La clorofila "a" lejos de la costa presentó concentraciones bajas y relativamente uniformes con la profundidad, con un promedio de 0.60 ug/L en la columna 0-25 m, mientras que cerca de la costa su distribución vertical fue irregular presentando también valores bajos con relación al promedio del área debido a los efectos del Fenómeno El Niño de 1972-73.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to estimate the energy cost of linear (EC) and vertical displacement (ECvert), mechanical efficiency and main stride parameters during simulated ski mountaineering at different speeds and gradients, to identify an optimal speed and gradient that maximizes performance. 12 subjects roller skied on a treadmill at three different inclines (10, 17 and 24 %) at three different speeds (approximately 70, 80 and 85 % of estimated peak heart rate). Energy expenditure was calculated by indirect calorimetry, while biomechanical parameters were measured with an inertial sensor-based system. At 10 % there was no significant change with speed in EC, ECvert and mechanical efficiency. At 17 and 24 % the fastest speed was significantly more economical. There was a significant effect of gradient on EC, ECvert and mechanical efficiency. The most economical gradient was the steepest one. There was a significant increase of stride frequency with speed. At steep gradients only, relative thrust phase duration decreased significantly, while stride length increased significantly with speed. There was a significant effect of gradient on stride length (decrease with steepness) and relative thrust phase duration (increase with steepness). A combination of a decreased relative thrust phase duration with increased stride length and frequency decreases ECvert. To minimize the energy expenditure to reach the top of a mountain and to optimize performance, ski-mountaineers should choose a steep gradient (~24 %) and, provided they possess sufficient metabolic scope, combine it with a fast speed (~6 km h(-1)).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Zubarev equation of motion method has been applied to an anharmonic crystal of O( ,,4). All possible decoupling schemes have been interpreted in order to determine finite temperature expressions for the one phonon Green's function (and self energy) to 0()\4) for a crystal in which every atom is on a site of inversion symmetry. In order to provide a check of these results, the Helmholtz free energy expressions derived from the self energy expressions, have been shown to agree in the high temperature limit with the results obtained from the diagrammatic method. Expressions for the correlation functions that are related to the mean square displacement have been derived to 0(1\4) in the high temperature limit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The infrared and the Raman spectra of eSelF has been obtained for the first time and has been analysed to give the in-plane normal vibrational frequencies of the molecule, in the ground state. A normal co-ordinate analysis has been carried out for the molecules CSF2, CSClF and eSel 2 using a Urey-Bradley type of potential function and the elements of the [L] matrix elements, the distribution of the potential energy in Urey-Bradley space, and the displacement vector diagrams for the normal modes of vibration for these molecules, have been obtained. The bond for~e constants obtained through the normal co-ordinate analysis, have given some interesting results. The stretching force constant, Kes ' varies markedly with halogen substitution and the force constants KeF and Keel also vary with substitution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Interior layered deposits within an embayment in the northern as well as near the southern wall of Coprates Chasma in the Valles Marineris, Mars are studied using HRSC, CTX, HiRISE and CRISM data. In the northern embayment, layered deposits outcrop in three separate locations (a western deposit, a central deposit and an eastern deposit). The central layered deposit in the north has a stratigraphic thickness of 2 km. The western layered deposit abuts against the chasma wall appearing to have a relatively un-eroded depositional surface. The eastern deposit is near a landslide scar which appears to have exposed basement layering showing downward displacement. This northern embayment is suggested to have been an ancestral basin. The triangular edged deposit near the southern wall of Coprates Chasma has an elongated mound protruding from the central edge and is suggested to be the outer limits of a fault block which is back rotated 6° south. The rotation may be the result of the Valles Marineris opening.