872 resultados para VALIDATION
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Background: The objective of this study was to evaluate the consistency, coherence, and interobserver reliability of the Portuguese version of the Scandinavian Stroke Scale (SSS) in a multicultural population of stroke. Methods: The SSS was translated, culturally adapted, and applied by two independent investigators. This was a randomized transverse study involving two groups: group 1 included 20 patients in the acute phase and group 2 included 20 patients in the subacute phase after stroke was confirmed by computed tomography with a pre-stroke modified Rankin Scale score of 0. Each patient also underwent National Institutes of Health Stroke Scale (NIHSS) evaluation at hospital entry and at the time of the SSS evaluation for correlation with our current standard hospital practice. Consistency and coherence were analyzed by Cronbach’s α and interobserver reliability by ĸ. Results: Forty patients were evaluated with 0.88 consistency and coherence in both stroke phases. Mean interobserver ĸ was 0.76, with reliability considered excellent and good for most scale items, and moderate for only the facial palsy item. Conclusion: The SSS is adequate and validated to study post-stroke patients in a multicultural Brazilian population and in the Portuguese language.
Resumo:
The canis lupus familiares is the only species besides human that spontaneously develop prostatic carcinoma (PCa). In addition, the metastatic sites are similar to those frequently reported in men. For these reasons, the dog is the best natural model to study the molecular mechanisms in PCa development providing a natural animal model for treatment by molecular targets. Previously, we investigated copy number alterations by arrayCGH (Canine Genome CGH Microarray 4x44K-G2519F, Agilent Technologies) in canine prostatic lesions: 3 benign prostatic hyperplasias (BPH), 4 proliferative inflammatory atrophies (PIA), and 14 PCa. Five histologically normal prostatic tissues were used as reference. Genomic alterations were evaluated using Genomic Workbench Standard Edition 5.0.14. This previous study revealed significant copy number losses of Atm and Pten exclusively in PCa. In the present study, ATM and PTEN immunoexpression were investigated using a tissue microarray (TMA) containing 149 canine prostatic paraffin-embedded lesions (BPH, PIA and PCa) collected from 67 animals. Immunohistochemical reactions were performed using the polyclonal rabbit antibody anti-PTEN (Santa Cruz Biotech, 1:50) and anti-ATM (Abcam, 1:50). The sections were developed with diaminobenzidine (DAB) and peroxidase. The immunohistochemical staining was assessed in each core by the distribution of positive cells for each antibody per lesion (score 1: <25% cells positive, 2: 26% to 50%, 3: being 51% and 75% and 4:> 75%) and intensity (1: weak, 2: moderate, 3: intense). Chi-square or Fisher exact test was used to determine the association between the categorical variables using GraphPad Prism 5 (GraphPad Software Inc., La Jolla, CA). Distribution of positive cells did not differ among lesions. PCa and PIA showed more samples with weak intensity for ATM when compared to normal prostatic tissue and BPH (PCa: p=0,032 and PIA: p=0,025). Benign prostatic hyperplasia and normal samples presented intense PTEN immunostaining than PCa (p=0,021) and PIA (p=0,0013). These results suggest that ATM and PTEN proteins expression in canine prostatic carcinoma are downregulated possibly by copy number losses. These findings are similar from those described in prostate carcinomas from human corroborating for the use of dogs as a natural model to study prostatic disease in men.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A simple and sensitive analytical method for simultaneous determination of anastrozole, bicalutamide, and tamoxifen as well as their synthetic impurities, anastrozole pentamethyl, bicalutamide 3-fluoro-isomer, and tamoxifen e-isomer, was developed and validated by using high performance liquid chromatography (HPLC). The separation was achieved on a Symmetry (R) C-8 column (100 x 4.6 mm i.d., 3.5 mu m) at room temperature (+/- 24 degrees C), with a mobile phase consisting of acetonitrile/water containing 0.18% N,N dimethyloctylamine and pH adjusted to 3.0 with orthophosphoric acid (46.5/53.5, v/v) at a flow rate of 1.0 mL min(-1) within 20 min. The detection was made at a wavelength of 270 nm by using ultraviolet (UV) detector. No interference peaks from excipients and relative retention time indicated the specificity of the method. The calibration curve showed correlation coefficients (r) > 0.99 calculated by linear regression and analysis of variance (ANOVA). The limit of detection (LOD) and limit of quantitation (LOQ), respectively, were 2.2 and 6.7 mu g mL(-1) for anastrozole, 2.61 and 8.72 mu g mL(-1) for bicalutamide, 2.0 and 6.7 mu g mL(-1) for tamoxifen, 0.06 and 0.22 mu g mL(-1) for anastrozole pentamethyl, 0.02 and 0.07 mu g mL(-1) for bicalutamide 3-fluoro-isomer, and 0.002 and 0.007 mu g mL(-1) for tamoxifen e-isomer. Intraday and interday relative standard deviations (RSDs) were <2.0% (drugs) and <10% (degradation products) as well as the comparison between two different analysts, which were calculated by f test. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
DEVELOPMENT AND VALIDATION OF A HPLC METHOD FOR QUANTIFICATION OF URSOLIC ACID IN SOLID DISPERSIONS. Ursolic acid is a natural molecule that presents several pharmacological properties. In this work, an analytical method by RP-HPLC has been developed and validated for quantification of this drug in the solid dispersions, using PEG 6000 and Poloxamer 407 as polymers. The method was specific, linear in the range of 1.0-50.0 mu g mL(-1) (r<0.99), precise (CV < 5% for both inter-and intra-assays), accurate (maximum deviation of +/- 13%), and robust to the parameters evaluated. This method has proved to be simple and useful for ursolic acid determination in solid dispersions, enabling its determination in pharmaceutical dosage form.
Resumo:
DEVELOPMENT AND VALIDATION OF AN ANALYTICAL METHOD FOR QUANTITATION OF THE DRUG BEVACIZUMAB BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY. In this study, an analytical method was developed and validated for quantitation of the drug bevacizumab (Avastin (R)) by high performance liquid chromatography (HPLC). The HPLC column was a BioSuite 250 (R) HR SEC, 300 x 7.8 mm x 5 mu m (Waters, USA). The mobile phase consisted of phosphate buffered saline (PBS). The results revealed that the method was specific, precise. accurate, robust and linear (r(2) = 0.998) from 5 to 75 mu g mL(-1). Therefore, this method can be used in drug release studies or in quality control ampoules of the drug.
Resumo:
The purpose of the current study was to examine the psychometric properties of the Portuguese version of the Duke Religion Index (PDUREL) in a community setting. PDUREL was translated and adapted for administration to 383 individuals from a population-based study of low-income community-dwelling adults. The PDUREL intrinsic subscale and total scores demonstrated high internal consistency (alphas ranging from 0.733 for the total scale score to 0.758 for the intrinsic subscale). Correlations among the DUREL subscales were also examined for evidence of discriminant validity. Correlations were ranging from 0.36 to 0.46, indicating significant overlap between the scales without marked redundancy. PDUREL is a reliable and valid scale. The availability of a comprehensive, but brief measure of religiousness can help to study the role of religiousness in health by researchers from countries that speak the Portuguese language.
Resumo:
When a physical activity professional is teaching a motor skill, he evaluates the movement's learner and considers which interventions could be done at the moment. However, many times the instructor does not have such resources which could help him/her to evaluate the learner movement. The skill acquisition process could be facilitated if instructors could have an instrument that identifies errors, prioritizing information to be given to the learner. Considering that the specialized literature presents a lack of information about such tool, the purpose of this study was to develop, and to determine the objectivity and reliability of an instrument to assess the movement quality of the basketball free throw shooting. The checklist was developed and evaluated by basketball experts. Additionally, the checklist was used to assess 10 trials (edited video) from four individuals in different learning stages. Data were organized by the critical error and the error sum appointed by the experts in two different occasions (one week interval). Contrasting both evaluations, and also, contrasting different experts assessments, in sum and critical error, it was observed an average error of 16.9%. It was concluded that the checklist to assess the basketball free throw is reliable, and could help instructors to make a qualitative analysis. Moreover, the checklist may allow instructors to make assumptions on the motor learning process.
Resumo:
'Objectives: To analyse the validity of the Brazilian versions of OHIP-EDENT and GOHAI as assessment tools of edentulous subjects' OHRQoL. Background: Inventories for measuring oral health-related quality of life (OHRQoL) are important in clinical studies regarding oral rehabilitation. However, there is a need for comprehensive validation after translation into different cultural settings. Materials and methods: The sample comprised of 100 complete denture wearers (29 men, 71 women, mean age of 65.2 +/- 9.9 years). The associations between each OHRQoL inventory and other variables served as measurements of construct validity. Data analysis comprised the Spearman correlation test as well as multiple regression using the OHRQoL inventories as dependent variables and the other scales as determinants. Results: Both OHRQoL inventories showed good correlation with denture satisfaction, whereas lower correlation coefficients were found among the inventories and the HAD subscales. Denture satisfaction alone explained 48% and 39% of the variance found for the OHIP-EDENT and GOHAI, respectively, as assessed by multiple regression. A smaller effect was found for OHIP-EDENT. Conclusion: Both OHIP-EDENT and GOHAI showed good construct validity for measurement of OHRQoL of edentulous subjects.
Resumo:
Background: Stable angina pectoris is a serious condition with few epidemiological studies in Brazil. Objective: To validate the short-version of the Rose angina questionnaire in Brazilian Portuguese for its implementation in surveys and longitudinal studies. Methods: A total of 116 consecutive patients from an outpatient clinic without prior myocardial infarction and/or coronary revascularization were enrolled for application of three questions of the Rose angina questionnaire addressing chest pain after exertion. We used the treadmill test as the gold standard with the Ellestad protocol. Results: The short-version of the Rose angina questionnaire of the 116 subjects submitted to the exercise treadmill test disclosed 89.7% of accuracy, 25% of sensitivity, 92.0% of specificity, 10.0% of positive predictive value, 97.2% of negative predictive value, and 3.1 of positive likelihood ratio and 0.82 of negative likelihood ratio. Conclusion: The Portuguese version with three items of the Rose angina questionnaire is suitable for epidemiological purposes. (Arq Bras Cardiol 2012; 99(5): 1056-1059)
Resumo:
Background: The Beck Depression Inventory (BDI) is used worldwide for detecting depressive symptoms. This questionnaire has been revised (1996) to match the DSM-IV criteria for a major depressive episode. We assessed the reliability and the validity of the Brazilian Portuguese version of the BDI-II for non-clinical adults. Methods: The questionnaire was applied to 60 college students on two occasions. Afterwards, 182 community-dwelling adults completed the BDI-II, the Self-Report Questionnaire, and the K10 Scale. Trained psychiatrists performed face-to-face interviews with the respondents using the Structured Clinical Interview (SCID-I), the Montgomery-angstrom sberg Depression Scale, and the Hamilton Anxiety Scale. Descriptive analysis, signal detection analysis (Receiver Operating Characteristics), correlation analysis, and discriminant function analysis were performed to investigate the psychometric properties of the BDI-II. Results: The intraclass correlation coefficient of the BDI-II was 0.89, and the Cronbach's alpha coefficient of internal consistency was 0.93. Taking the SCID as the gold standard, the cut-off point of 10/11 was the best threshold for detecting depression, yielding a sensitivity of 70% and a specificity of 87%. The concurrent validity (a correlation of 0.63-0.93 with scales applied simultaneously) and the predictive ability of the severity level (over 65% correct classification) were acceptable. Conclusion: The BDI-II is reliable and valid for measuring depressive symptomatology among Portuguese-speaking Brazilian non-clinical populations.