982 resultados para STEADY-STATE VOLTAMMOGRAMS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The measurement and analysis of the microwave frequency response of semiconductor optical amplifiers (SOAs) are proposed in this paper. The response is measured using a vector network analyzer. Then with the direct-subtracting method, which is based on the definition of scattering parameters of optoelectronic devices, the responses of both the optical signal source and the photodetector are eliminated, and the response of only the SOA is extracted. Some characteristics of the responses can be observed: the responses are quasi-highpass; the gain increases with the bias current; and the response becomes more gradient while the bias current is increasing. The multisectional model of an SOA is then used to analyze the response theoretically. By deducing from the carrier rate equation of one section under the steady state and the small-signal state, the expression of the frequency response is obtained. Then by iterating the expression, the response of the whole SOA is simulated. The simulated results are in good agreement with the measured on the three main characteristics, which are also explained by the deduced results. This proves the validity of the theoretical analysis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A three-dimensional analytical solution of the microheater temperature based on heat diffusion equation is developed and compared with experimental results. Dimensionless parameters are introduced to analyze the temperature rise time and the distribution under steady state. To study the microheater temperatures before bubble nucleation, a set of working fluids and microheaters are considered. It is shown that the dimensionless time xi(-)(0) required for the temperature rise from room to 95% of the steady state temperature is about 75, not dependent on working fluids and microheaters. Heat transfer to the surrounding liquid is mainly caused by conduction, not by convection and radiation mechanisms. The microheater length affects the surface temperature uniformity, while its width influences the steady temperatures significantly, yielding the transition from heterogeneous to homogeneous nucleation mechanism from square microheaters to narrow line microheaters. 

Relevância:

80.00% 80.00%

Publicador:

Resumo:

When a grating is recorded in a bacteriorhodopsin film by two linear parallel polarized beams together with anauxiliary violet light, the diffraction efficiency has a dependence on the polarization orientation of the violet light as well as its intensity. A method for calculating the diffraction efficiency of gratings in bacteriorhodopsin is proposed based on the two-state photochromic model, considering the saturation effect and the polarization status of all the involved lights. It is found that the polarization orientation of the violet light produces an approximate-cosine and an approximate-sine modulation on the steady-state diffraction efficiency separately at low and high intensities, respectively. The parallel polarized violet light can improve the steady-state diffraction efficiency to a larger degree than the perpendicularly polarized violet light when both are at their optimal intensities. The optimal intensity for the parallel polarized violet light is lower than that of the perpendicular polarized one. Thus, the improvement of the steady-state diffraction efficiency is less sensitive to the intensity of perpendicular polarized violet light than to that of parallel polarized violet light. (C) 2008 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Anisotropic gratings are recorded on bacteriorhodopsin films by two parallelly polarized beams, and the effect of the polarization orientation of the reconstructing beam on the diffraction efficiency kinetics is studied. A theoretical model for the diffraction efficiency kinetics of the anisotropic grating is developed by combining Jones-matrix and photochromic two-state theory. It is found that the polarization azimuth of the reconstructing beam produces a cosine modulation on the kinetics of the diffraction efficiency, being positive at the peak efficiency and negative for steady state. By adding auxiliary violet light during grating formation, the saturation of the grating can be restrained. As a result, the negative cosine modulation for the steady-state diffraction efficiency changes to a positive one. In addition, the steady-state diffraction efficiency is increased appreciably for all reconstructing polarization orientations. (c) 2008 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the present research, two Chinese rhesus monkeys were inoculated intravenously with 5000 TCID50 of SIVmac239. The changes in the numbers of CD4+ T lymphocyte in peripheral blood, plasma viral loads, proviral DNA and humoral antibodies against virus were periodically monitored during 121 days. At the early stage of infection, proviral DNA had been detected in PBMCs, and infectious SIVmac239 virus had been isolated from PBMCs. At the same period, the numbers of CD4+ T lymphocytes were significantly decreased, and maintained at low level during the 121-day period of infection. Plasma viral loads reached the peak at week 2 post-inoculation and kept at a steady state subsequently. Moreover, antibodies against viral proteins were detected from plasma. All the results showed that the two Chinese rhesus monkeys had been infected with SIVmac239 successfully. This animal model can be applied for further AIDS researches.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nonresonant electron tunneling between asymmetric double quantum wells in AlxGa1-xAs/GaAs systems has been investigated by using steady-state and time-resolved photoluminescence spectra. Experimental evidence of LO-phonon-assisted tunneling through thick barriers has been obtained by enhancing excitation power densities or applying electric fields perpendicular to the well plane. LO-phonon-assisted tunneling times have also been estimated from the variation of the decay time of the narrow-well photoluminescence with applied electric fields. Our findings suggest that LO phonons in the barriers play an important role in the tunneling transfer.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Physical vapor transport studies of GeSe(x)Te1 - x (x = 0.1, 0.2, 0.3, and 0.4) solid solutions demonstrated, that individual, large single crystals of these materials can be grown in closed ampoules. A compositional analysis of the grown crystals revealed, that the mass transport (crystal growth) process under steady-state conditions is pseudo-congruent and controlled by diffusion processes in the source material. From these experiments, the degree of non-stoichiometry (Ge-vacancy concentrations) of GeSe(x)Te1 - x single crystals could be estimated. The effects of the cubic to rhombohedral phase transformation during cooling on the microstructure and morphology of the grown mixed crystals are observed. This work provides the basis for subsequent defect studies and electrical measurements on these crystals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The characteristics of the steady-state and the transient response to external light excitation of a common-cavity two-section (CCTS) bistable semiconductor laser is investigated. The results on the relation of light output versus light input, the wavelength match, optical amplification and optical switching are presented. Experimental results are compared to the results of a computer simulation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The chemical adsorption of sodium sulphide, ferrocene, hydroquinone and p-methyl-nitrobenzene onto the surface of a GaAs/AlxGa1-xAs multiquantum well semiconductor was characterized by steady state and time-resolved photoluminescence (PL) spectroscopy. The changes in the PL response, including the red shift of the emission peak of the exciton in the quantum well and the enhancement of the PL intensity, are discussed in terms of the interactions of the adsorbed molecules with surface states.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Subband separation energy dependence of intersubband relaxation time in a wide quantum well (250 Angstrom) was studied by steady-state and time-resolved photoluminescence. By applying a perpendicular electrical field, the subband separation energy in the quantum well is continuously tuned from 21 to 40 meV. As a result, it is found that the intersubband relaxation time undergoes a drastic change from several hundred picoseconds to subpicoseconds. It is also found that the intersubband relaxation has already become very fast before the energy separation really reaches one optical phonon energy. (C) 1997 American Institute of Physics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Transient photocurrents induced by short light pulses at lattice-matched GaAs/AlxGa1-xAs multiple quantum well (MQW) electrodes were studied as a function of electrode potential. Dual exponential photocurrent decay transients were observed at various potentials. By analysis of the dual exponential decay transients, information on steady state photocurrents (I-s), surface collection of photoexcited minority carriers (G(0)) and lifetimes of surface states (T-s) was obtained. The kinetic behaviors of photoprocesses at illuminated MQW/electrolyte interface were discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ultrashort pulses were generated in passively mode-locked Nd:YAG and Nd:GdVO4 lasers pumped by a pulsed laser diode with 10-Hz repetition rate. Stable mode-locked pulse trains were produced with the pulse width of 10 ps. The evolution of the mode-locked pulse was observed in the experiment and was discussed in detail. Comparing the pulse evolutions of Nd:YAG and Nd:GdVO4 lasers, we found that the buildup time of the steady-state mode-locking with semiconductor saturable absorber mirrors (SESAMs) was relevant to the upper-state lifetime and the emission cross-section of the gain medium.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An eigenfunction expansion-variational method based on a unit cell is developed to deal with the steady-state heat conduction problem of doubly-periodic fiber reinforced composites with interfacial thermal contact resistance or coating. The numerical results show a rapid convergence of the present method. The present solution provides a unified first-order approximation formula of the effective thermal conductivity for different interfacial characteristics and fiber distributions. A comparison with the present high-order results, available experimental data and micromechanical estimations demonstrates that the first-order approximation formula is a good engineering closed-form formula. An engineering equivalent parameter reflecting the overall influence of the thermal conductivities of the matrix and fibers and the interfacial characteristic on the effective thermal conductivity, is found. The equivalent parameter can greatly simplify the complicated relation of the effective thermal conductivity to the internal structure of a composite. (c) 2010 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For steady-state heat conduction a new variational functional for a unit cell of composites with periodic microstructures is constructed by considering the quasi-periodicity of the temperature field and in the periodicity of the heat flux fields. Then by combining with the eigenfunction expansion of complex potential which satisfies the fiber-matrix interface conditions, an eigenfunction expansion-variational method (EEVM) based on a unit cell is developed. The effective transverse thermal conductivities of doubly-periodic fiber reinforced composites are calculated, and the first-order approximation formula for the square and hexagonal arrays is presented,which is convenient for engineering application. The numerical results show a good convergency of the presented method, even through the fiber volume fraction is relatively high. Comparisons with the existing analytical and experimental results are made to demonstrate the accuracy and validity of the first-order approximation formula for the hexagonal array.