956 resultados para High performance concrete


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper, by investigating the influence of source/drain extension region engineering (also known as gate-source/drain underlap) in nanoscale planar double gate (DG) SOI MOSFETs, we offer new insights into the design of future nanoscale gate-underlap DG devices to achieve ITRS projections for high performance (HP), low standby power (LSTP) and low operating power (LOP) logic technologies. The impact of high-kappa gate dielectric, silicon film thickness, together with parameters associated with the lateral source/drain doping profile, is investigated in detail. The results show that spacer width along with lateral straggle can not only effectively control short-channel effects, thus presenting low off-current in a gate underlap device, but can also be optimized to achieve lower intrinsic delay and higher on-off current ratio (I-on/I-off). Based on the investigation of on-current (I-on), off-current (I-off), I-on/I-off, intrinsic delay (tau), energy delay product and static power dissipation, we present design guidelines to select key device parameters to achieve ITRS projections. Using nominal gate lengths for different technologies, as recommended from ITRS specification, optimally designed gate-underlap DG MOSFETs with a spacer-to-straggle (s/sigma) ratio of 2.3 for HP/LOP and 3.2 for LSTP logic technologies will meet ITRS projection. However, a relatively narrow range of lateral straggle lying between 7 to 8 nm is recommended. A sensitivity analysis of intrinsic delay, on-current and off-current to important parameters allows a comparative analysis of the various design options and shows that gate workfunction appears to be the most crucial parameter in the design of DG devices for all three technologies. The impact of back gate misalignment on I-on, I-off and tau is also investigated for optimized underlap devices.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The development of high performance, low computational complexity detection algorithms is a key challenge for real-time Multiple-Input Multiple-Output (MIMO) communication system design. The Fixed-Complexity Sphere Decoder (FSD) algorithm is one of the most promising approaches, enabling quasi-ML decoding accuracy and high performance implementation due to its deterministic, highly parallel structure. However, it suffers from exponential growth in computational complexity as the number of MIMO transmit antennas increases, critically limiting its scalability to larger MIMO system topologies. In this paper, we present a solution to this problem by applying a novel cutting protocol to the decoding tree of a real-valued FSD algorithm. The new Real-valued Fixed-Complexity Sphere Decoder (RFSD) algorithm derived achieves similar quasi-ML decoding performance as FSD, but with an average 70% reduction in computational complexity, as we demonstrate from both theoretical and implementation perspectives for Quadrature Amplitude Modulation (QAM)-MIMO systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The fabrication and performance of the first bit-level systolic correlator array is described. The application of systolic array concepts at the bit level provides a simple and extremely powerful method for implementing high-performance digital processing functions. The resulting structure is highly regular, facilitating yield enhancement through fault-tolerant redundancy techniques and therefore ideally suited to implementation as a VLSI chip. The CMOS/SOS chip operates at 35 MHz, is fully cascadable and exhibits 64-stage correlation for 1-bit reference and 4-bit data. 7 refs.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper discusses the beneficial influence of compressive membrane action in fibre reinforced polymer (FRP)reinforced in-plane restrained slabs in bridge deck slabs and the improved service performance when archingaction occurs. Bridge deck slabs that are exposed to extreme environmental conditions can experience severecorrosion damage. Expansive corrosion in steel reinforcement significantly reduces the design life and durabilityof concrete structures; for example, on one short section of the M1 in Northern Ireland, nearly £1 million was spent last year on the maintenance and repair of bridges due to corrosion. Corrosion-resistant compositereinforcement such as basalt fibre reinforced polymer (BFRP) and glass fibre reinforced polymer (GFRP) provides adurable alternative to reinforcing steel. In this research, two BFRP reinforced slabs and two GFRP reinforced slabswere constructed using high-strength concrete with a target cube compressive strength of 65 N/mm2. The slabsrepresented typical full-scale dimensions of a real bridge deck slab 475 mm wide by 1425 mm long and 150 mmdeep. The service and ultimate behaviour of the slabs are discussed and the results are compared with the relevantdesign guidelines.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A solvent-vapour thermoplastic bonding process is reported which provides high strength bonding of PMMA over a large area for multi-channel and multi-layer microfluidic devices with shallow high resolution channel features. The bond process utilises a low temperature vacuum thermal fusion step with prior exposure of the substrate to chloroform (CHCl3) vapour to reduce bond temperature to below the PMMA glass transition temperature. Peak tensile and shear bond strengths greater than 3 MPa were achieved for a typical channel depth reduction of 25 µm. The device-equivalent bond performance was evaluated for multiple layers and high resolution channel features using double-side and single-side exposure of the bonding pieces. A single-sided exposure process was achieved which is suited to multi-layer bonding with channel alignment at the expense of greater depth loss and a reduction in peak bond strength. However, leak and burst tests demonstrate bond integrity up to at least 10 bar channel pressure over the full substrate area of 100 mm x 100 mm. The inclusion of metal tracks within the bond resulted in no loss of performance. The vertical wall integrity between channels was found to be compromised by solvent permeation for wall thicknesses of 100 µm which has implications for high resolution serpentine structures. Bond strength is reduced considerably for multi-layer patterned substrates where features on each layer are not aligned, despite the presence of an intermediate blank substrate. Overall a high performance bond process has been developed that has the potential to meet the stringent specifications for lab-on-chip deployment in harsh environmental conditions for applications such as deep ocean profiling.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We describe a simple strategy, which is based on the idea of space confinement, for the synthesis of carbon coating on LiFePO4 nanoparticles/graphene nanosheets composites in a water-in-oil emulsion system. The prepared composite displayed high performance as a cathode material for lithium-ion battery, such as high reversible lithium storage capacity (158 mA h g-1 after 100 cycles), high coulombic efficiency (over 97%), excellent cycling stability and high rate capability (as high as 83 mA h g -1 at 60 C). Very significantly, the preparation method employed can be easily adapted and be extended as a general approach to sophisticated compositions and structures for the preparation of highly dispersed nanosized structure on graphene. 

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A facile method to synthesize well-dispersed TiO2 quantum dots on graphene nanosheets (TiO2-QDs/GNs) in a water-in-oil (W/O) emulsion system is reported. The TiO2/graphene composites display high performance as an anode material for lithium-ion batteries (LIBs), such as having high reversible lithium storage capacity, high Coulombic efficiency, excellent cycling stability, and high rate capability. The excellent electrochemical performance and special structure of the composites thus offer a way to prepare novel graphene-based electrode materials for high-energy-density and high-power LIBs. 

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Les troubles reliés à la dépression, l’épuisement professionnel et l’anxiété sont de plus en plus répandus dans notre société moderne. La consommation croissante d’antidépresseurs dans les différents pays du monde est responsable de la récente détection de résidus à l’état de traces dans les rejets urbains municipaux. Ainsi, ces substances dites « émergentes » qui possèdent une activité pharmacologique destinée à la régulation de certains neurotransmetteurs dans le cerveau suscitent maintenant de nombreuses inquiétudes de la part de la communauté scientifique. L’objectif principal de ce projet de doctorat a été de mieux comprendre le devenir de plusieurs classes d’antidépresseurs présents dans diverses matrices environnementales (i.e. eaux de surfaces, eaux usées, boues de traitement, tissus biologiques) en développant de nouvelles méthodes analytiques fiables capables de les détecter, quantifier et confirmer par chromatographie liquide à haute performance couplée à la spectrométrie de masse en tandem (LC-QqQMS, LC-QqToFMS). Une première étude complétée à la station d’épuration de la ville de Montréal a permis de confirmer la présence de six antidépresseurs et quatre métabolites N-desmethyl dans les affluents (2 - 330 ng L-1). Pour ce traitement primaire (physico-chimique), de faibles taux d’enlèvement (≤ 15%) ont été obtenus. Des concentrations d’antidépresseurs atteignant près de 100 ng L-1 ont également été détectées dans le fleuve St-Laurent à 0.5 km du point de rejet de la station d’épuration. Une seconde étude menée à la même station a permis l’extraction sélective d’antidépresseurs dans trois tissus (i.e. foie, cerveau et filet) de truites mouchetées juvéniles exposées à différentes concentrations d’effluent dilué traité et non-traité à l’ozone. Un certain potentiel de bioaccumulation dans les tissus (0.08-10 ng g-1) a été observé pour les spécimens exposés à l’effluent non-traité (20% v/v) avec distribution majoritaire dans le foie et le cerveau. Une intéressante corrélation a été établie entre les concentrations de trois antidépresseurs dans le cerveau et l’activité d’un biomarqueur d’exposition (i.e. pompe N/K ATPase impliquée dans la régulation de la sérotonine) mesurée à partir de synaptosomes de truites exposées aux effluents. Une investigation de l’efficacité de plusieurs stations d’épuration canadiennes opérant différents types de traitements a permis de constater que les traitements secondaires (biologiques) étaient plus performants que ceux primaires (physico-chimiques) pour enlever les antidépresseurs (taux moyen d’enlèvement : 30%). Les teneurs les plus élevées dans les boues traitées (biosolides) ont été obtenues avec le citalopram (1033 ng g-1), la venlafaxine (833 ng g-1) et l’amitriptyline (78 ng g-1). Des coefficients de sorption expérimentaux (Kd) calculés pour chacun des antidépresseurs ont permis d’estimer une grande sorption des composés sertraline, desméthylsertraline, paroxetine et fluoxetine sur les solides (log Kd > 4). Finalement, un excellent taux d’enlèvement moyen de 88% a été obtenu après ozonation (5 mg L-1) d’un effluent primaire. Toutefois, la caractérisation de nouveaux sous-produits N-oxyde (venlafaxine, desmethylvenlafaxine) par spectrométrie de masse à haute résolution (LC-QqToFMS) dans l’effluent traité à l’ozone a mis en lumière la possibilité de formation de multiples composés polaires de toxicité inconnue.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Travail dirigé présenté à la Faculté des Sciences Infirmières en vue de l’obtention du grade de Maître ès Sciences (M. Sc.) en sciences infirmière option administration des sciences infirmières

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Les ombres sont un élément important pour la compréhension d'une scène. Grâce à elles, il est possible de résoudre des situations autrement ambigües, notamment concernant les mouvements, ou encore les positions relatives des objets de la scène. Il y a principalement deux types d'ombres: des ombres dures, aux limites très nettes, qui résultent souvent de lumières ponctuelles ou directionnelles; et des ombres douces, plus floues, qui contribuent à l'atmosphère et à la qualité visuelle de la scène. Les ombres douces résultent de grandes sources de lumière, comme des cartes environnementales, et sont difficiles à échantillonner efficacement en temps réel. Lorsque l'interactivité est prioritaire sur la qualité, des méthodes d'approximation peuvent être utilisées pour améliorer le rendu d'une scène à moindre coût en temps de calcul. Nous calculons interactivement les ombres douces résultant de sources de lumière environnementales, pour des scènes composées d'objets en mouvement et d'un champ de hauteurs dynamique. Notre méthode enrichit la méthode d'exponentiation des harmoniques sphériques, jusque là limitée aux bloqueurs sphériques, pour pouvoir traiter des champs de hauteurs. Nous ajoutons également une représentation pour les BRDFs diffuses et glossy. Nous pouvons ainsi combiner les visibilités et BRDFs dans un même espace, afin de calculer efficacement les ombres douces et les réflexions de scènes complexes. Un algorithme hybride, qui associe les visibilités en espace écran et en espace objet, permet de découpler la complexité des ombres de la complexité de la scène.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Triple quadrupole mass spectrometers coupled with high performance liquid chromatography are workhorses in quantitative bioanalyses. It provides substantial benefits including reproducibility, sensitivity and selectivity for trace analysis. Selected Reaction Monitoring allows targeted assay development but data sets generated contain very limited information. Data mining and analysis of non-targeted high-resolution mass spectrometry profiles of biological samples offer the opportunity to perform more exhaustive assessments, including quantitative and qualitative analysis. The objectives of this study was to test method precision and accuracy, statistically compare bupivacaine drug concentration in real study samples and verify if high resolution and accurate mass data collected in scan mode can actually permit retrospective data analysis, more specifically, extract metabolite related information. The precision and accuracy data presented using both instruments provided equivalent results. Overall, the accuracy was ranging from 106.2 to 113.2% and the precision observed was from 1.0 to 3.7%. Statistical comparisons using a linear regression between both methods reveal a coefficient of determination (R2) of 0.9996 and a slope of 1.02 demonstrating a very strong correlation between both methods. Individual sample comparison showed differences from -4.5% to 1.6% well within the accepted analytical error. Moreover, post acquisition extracted ion chromatograms at m/z 233.1648 ± 5 ppm (M-56) and m/z 305.2224 ± 5 ppm (M+16) revealed the presence of desbutyl-bupivacaine and three distinct hydroxylated bupivacaine metabolites. Post acquisition analysis allowed us to produce semiquantitative evaluations of the concentration-time profiles for bupicavaine metabolites.