878 resultados para Filters and filtration.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The power-handling capabilities of helical resonator filters for space applications are discussed. Emerging difficulties due to the multipaction effects are highlighted. A method is proposed to increase specified power handling without significantly sacrificing the size/quality factor. Experimental verification is attained by means of a fabricated prototype for which measured filter response and multipaction test results are obtained and presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The quality factor of microwave resonators miniaturised by virtue of periodic loading is assessed. Five X-band resonators in E-plane technology with different miniaturisation factors have been designed to resonate at approximately the same frequency. The loaded quality factor is extracted from the fractional bandwidth and subsequently employed to estimate the unloaded quality factor. The study reveals that the unloaded quality factor drops approximately linearly with the miniaturisation. Subsequently design guidelines for E-plane filters with periodically loaded resonators are provided by means of an example involving a fifth-order filter. Full-wave simulated and experimental results are presented to validate the study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Inappropriate prescribing is a well-documented problem in older people. The new screening tools, STOPP (Screening Tool of Older Peoples' Prescriptions) and START (Screening Tool to Alert doctors to Right Treatment) have been formulated to identify potentially inappropriate medications (PIMs) and potential errors of omissions (PEOs) in older patients. Consistent, reliable application of STOPP and START is essential for the screening tools to be used effectively by pharmacists. OBJECTIVE: To determine the interrater reliability among a group of clinical pharmacists in applying the STOPP and START criteria to elderly patients' records. METHODS: Ten pharmacists (5 hospital pharmacists, 5 community pharmacists) were given 20 patient profiles containing details including the patients' age and sex, current medications, current diagnoses, relevant medical histories, biochemical data, and estimated glomerular filtration rate. Each pharmacist applied the STOPP and START criteria to each patient record. The PIMs and PEOs identified by each pharmacist were compared with those of 2 academic pharmacists who were highly familiar with the application of STOPP and START. An interrater reliability analysis using the k statistic (chance corrected measure of agreement) was performed to determine consistency between pharmacists. RESULTS: The median ? coefficients for hospital pharmacists and community pharmacists compared with the academic pharmacists for STOPP were 0.89 and 0.88, respectively, while those for START were 0.91 and 0.90, respectively. CONCLUSIONS: Interrater reliability of STOPP and START tools between pharmacists working in different sectors is good. Pharmacists working in both hospitals and in the community can use STOPP and START reliably during their everyday practice to identify PIMs and PEOs in older patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Novel V-band substrate integrated waveguide (SIW) filters have been presented. Design procedures for the filters synthesis and mechanisms providing quasi-elliptic response have been explained. The insertion loss of the filters has been measured below 2 dB with microstrip-to-SIW transitions being included.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Constructed wetland systems (CWS) have been used as a low cost bio-filtration system to treat farm wastewater. While studies have shown that CWS are efficient in removing organic compounds and pathogens, there is limited data on the presence of hormones in this type of treatment system. The objective of this study was to evaluate the ability of the CWS to reduce estrogenic and androgenic hormone concentration in dairy wastewater. This was achieved through a year long study on dairy wastewater samples obtained froma surface flow CWS. Analysis of hormonal levels was performed using a solid phase extraction (SPE) sample clean-up method, combined with reporter gene assays (RGAs) which incorporate relevant receptors capable of measuring total estrogenic or androgenic concentrations as low as 0.24 ng L1 and 6.9 ng L1 respectively. Monthly analysis showed a mean removal efficiency for estrogens of 95.2%, corresponding to an average residual concentration of 3.2 ng L1 17b-estradiol equivalent (EEQ), below the proposed lowest observable effect concentration (LOEC) of 10 ng L1. However, for one month a peak EEQ concentration of 115 ng L1 was only reduced to 18.8 ng L1. The mean androgenic activity peaked at 360 ng L1 and a removal efficiency of 92.1% left an average residual concentration of 32.3 ng L1 testosterone equivalent (TEQ). The results obtained demonstrate that this type of CWS is an efficient system for the treatment of hormones in dairy wastewater. However, additional design improvements may be required to further enhance removal efficiency of peak hormone concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new inline coupling topology for narrowband helical resonator filters is proposed that allows to introduce selectively located transmission zeros (TZs) in the stopband. We show that a pair of helical resonators arranged in an interdigital configuration can realize a large range of in-band coupling coefficient values and also selectively position a TZ in the stopband. The proposed technique dispenses the need for auxiliary elements, so that the size, complexity, power handling and insertion loss of the filter are not compromised. A second order prototype filter with dimensions of the order of 0.05 lambda, power handling capability up to 90 W, measured insertion loss of 0.18 dB and improved selectivity is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rural point sources of phosphorus (P), including septic tank systems, provide a small part of the overall phosphorus budget to surface waters in agricultural catchments but can have a disproportionate impact on the low flow P concentration of receiving rivers. This has particular importance as the discharges are approximately constant into receiving waters and these have restricted dilution capacity during ecologically sensitive summer periods. In this study, a number of identified high impact septic systems were replaced with modern sequential batch reactors in three rural catchments during a monitoring period of 4 years. Sub-hourly P monitoring was conducted using bankside-analysers. Results show that strategic replacement of defective septic tank systems with modern systems and polishing filters decreased the low flow P concentration of one catchment stream by 0.032 mg TP L- 1 (0.018 mg TRP L- 1) over the 4 years. However two of the catchment mitigation efforts were offset by continued new-builds that increased the density of septic systems from 3.4 km- 2 to 4.6 km- 2 and 13.8 km- 2 to 17.2 km- 2 and subsequently increased low flow P concentrations. Future considerations for septic system mitigation should include catchment carrying capacity as well as technology changes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gabor features have been recognized as one of the most successful face representations. Encouraged by the results given by this approach, other kind of facial representations based on Steerable Gaussian first order kernels and Harris corner detector are proposed in this paper. In order to reduce the high dimensional feature space, PCA and LDA techniques are employed. Once the features have been extracted, AdaBoost learning algorithm is used to select and combine the most representative features. The experimental results on XM2VTS database show an encouraging recognition rate, showing an important improvement with respect to face descriptors only based on Gabor filters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1. Since salt depletion stimulates the renal prostaglandin system to maintain renal function, the effects of indomethacin and ibuprofen upon renal haemodynamics, electrolyte excretion and renin release were examined in eight healthy male volunteers on a salt restricted diet, before and after frusemide administration. 2. Neither indomethacin (50 mg) nor ibuprofen (400 mg and 800 mg) affected renal blood flow, glomerular filtration rate or electrolyte excretion before frusemide. 3. Renal blood flow and glomerular filtration rate were significantly increased in the first 20 min after frusemide. These changes were significantly attenuated by indomethacin compared with placebo and ibuprofen 400 mg. Frusemide-induced diuresis but not natriuresis was inhibited by all treatments. 4. Both nonsteroidal agents inhibited equally the rise in renin activity seen after frusemide. 5. In this group of healthy volunteers on a salt restricted diet, ibuprofen and indomethacin had no detrimental effects on renal function in the absence of frusemide. The changes in renal haemodynamics due to frusemide were suppressed more by indomethacin than by ibuprofen, probably reflecting the more potent nature of indomethacin as an inhibitor of prostaglandin synthesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1. This study has compared the effects of ibuprofen and indomethacin upon renal haemodynamics, electrolyte excretion and renin release in the presence and absence of frusemide under sodium replete conditions in eight healthy volunteers. 2. Neither ibuprofen (400 mg and 800 mg) nor indomethacin (50 mg) affected renal blood flow, glomerular filtration rate or electrolyte excretion in the basal state. 3. Frusemide had no effect on renal blood flow, but significantly increased glomerular filtration rate. This latter change was suppressed significantly only by ibuprofen 400 mg. Frusemide-induced diuresis was inhibited by all treatments, while natriuresis following frusemide was inhibited by indomethacin only. 4. Significant increments in plasma renin activity, which were suppressed by all treatments, were observed after frusemide. The degree of inhibition of the renin responses was significantly greater in the presence of indomethacin than with either dose of ibuprofen. 5. In a sodium replete setting in healthy volunteers, indomethacin and ibuprofen had no detrimental effects on basal renal function. In the presence of frusemide, indomethacin had more anti-natriuretic and renin-suppressing effect than ibuprofen. There was no evidence for a dose-related effect of ibuprofen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

1. In a fourway double-blind placebo controlled study, the effects of cilazapril, a new angiotensin converting enzyme inhibitor, on renal function and the responses to intravenous frusemide were studied in a group of twelve salt depleted male volunteers. 2. Cilazapril produced an increase in effective renal plasma flow and urinary output of prostaglandin E2 metabolite (PGE2-M) but no effect on sodium, potassium or water excretion. 3. Pretreatment with cilazapril antagonised the effects of frusemide on glomerular filtration, PGE2-M and sodium excretion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, a number of most significant digit (msd) first bit parallel multipliers for recursive filtering have been reported. However, the design approach which has been used has, in general, been heuristic and consequently, optimality has not always been assured. In this paper, msd first multiply accumulate algorithms are described and important relationships governing the dependencies between latency, number representations, etc are derived. A more systematic approach to designing recursive filters is illustrated by applying the algorithms and associated relationships to the design of cascadable modules for high sample rate IIR filtering and wave digital filtering.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whilst conventional bit level pipelining introduces an m cycle delay, it does allow m separate computations to be processed at throughput rates comparable to that using word level systolic arrays. We concentrate on exploiting this delay and describe a systematic method for the design of high performance multiplexed IIR filters. Two multiply and accumulate structures are identified based on shift-and-add and carry-save data organisations which can be used as building blocks in the design of IIR filters. By replacing the word level multiply and accumulate units in word level systolic structures with their equivalent bit level circuits and introducing latches to ensure correct timing, numerous architectures can be designed that process multiplexed data directly without any additional circuit overhead.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel bit-level systolic array architecture for implementing first-order IIR filter sections is presented. A latency of only two clock cycles is achieved by using a radix-4 redundant number representation, performing the recursive computation most-significant-digit first, and feeding back each digit of the result as soon as it is available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel bit-level systolic array architecture for implementing bit-parallel IIR filter sections is presented. The authors have shown previously how the fundamental obstacle of pipeline latency in recursive structures can be overcome by the use of redundant arithmetic in combination with bit-level feedback. These ideas are extended by optimizing the degree of redundancy used in different parts of the circuit and combining redundant circuit techniques with those of conventional arithmetic. The resultant architecture offers significant improvements in hardware complexity and throughput rate.