923 resultados para Doses de Radiação
Resumo:
The aim of this study was to evaluate the effective dose received by patients undergoing CCTA in both acquisition methods in the period June 1st to October 30th, 2013. Data collection was performed at the Clínica Sabedotti in Ponta Grossa/PR, with General Electric Equipment VCT XT, 64 detections lines. The effective dose was measured from the thirty cases randomly selected of Picture Archival and Communication System – PACS, reported by Dose Lenght Product (DLP) equipment for each examination and the conversion factor (EDLP) set by the European Commission for cardiac region (EDLP = 0.014). The results showed significant differences in radiation dose delivered to the patient according to the employee acquisition method, Retrospective or Prospective of ECG.
Resumo:
A produção mundial de nanomateriais tem aumentado nos últimos anos, em função de suas variadas aplicações tecnológicas e, como consequência do seu crescente uso e demanda, poderão existir riscos ambientais sendo a água o ambiente onde muitas destas substâncias podem exercer efeitos deletérios. Um dos nanomaterias de carbono mais utilizados é o fulereno, um composto orgânico lipofílico que pode se comportar como carreador de moléculas tóxicas, potencializando a entrada de contaminantes ambientais em órgãos específicos, fenômeno conhecido como “cavalo de Troia”. As microcistinas (MC) são cianotoxinas produzidas por cianobactérias durante episódios de floração, afetando aos organismos aquáticos e ao ser humano. Diversos estudos demonstram que organismos expostos tanto às MCs quanto ao fulereno podem causar produção excessiva de espécies ativas de oxigênio e alterar os níveis de antioxidantes. Além disso, outro fator que pode vir a intensificar o potencial tóxico de ambos é a incidência de radiação UVA. Sendo assim, procurou-se avaliar os efeitos em parâmetros de estresse oxidativo da co-exposição ex vivo da cianotoxina microcistina-LR (MC-LR) e o nanomaterial de carbono fulereno em brânquias do peixe Cyprinus carpio sob incidência de radiação UVA. Os resultados mostraram que: (a) houve uma perda da capacidade antioxidante no tratamento com MC-LR (baixa concentração) quando coexposta com fulereno no UVA em relação com o tratamento realizado sem co-exposição com fulereno; (b) o fulereno no UV diminuiu a atividade da enzima glutationa-Stransferase (GST) quando comparado com o controle no UV; (c) a MC-LR (alta concentração) co-exposta com fulereno foi capaz de diminuir as concentrações do antioxidante glutationa (GSH) quando comparado com o mesmo tratamento tanto no UVA quanto no escuro sem a co-exposição ao fulereno; (d) o tratamento MC-LR (baixa concentração) com UVA aumentou o dano oxidativo lipídico quando comparado com o controle UVA; (e) o fulereno não causou uma maior bioacumulação da microcistina no tecido. Sendo assim, pode-se concluir que o fulereno não apresentou o potencial de carregador de moléculas nessas concentrações de microcistina, porém, a co-exposição dos compostos diminuem tanto capacidade antioxidante total, como a concentração da GSH, podendo gerar problemas a longo prazo na detoxificação da toxina.
Resumo:
A irradiação é uma técnica de conservação acreditada para ingredientes secos e representa quase 50% do mercado mundial relativamente à desinfestação póscolheita (~186 000 ton). Para além da sua aplicabilidade para conservação apresentase também, como uma solução adequada para o tratamento pós-colheita de plantas medicinais, a fim de garantir a sua descontaminação [1,2]. Neste estudo, foram avaliados os efeitos da radiação gama (1 e 10 kGy) na composição química de amostras de Ginkgo biloba L. desidratadas. Foram analisadas moléculas lipofílicas e hidrofílicas utilizando técnicas cromatográficas acopladas a diferentes detetores. Os açúcares livres foram analisados por HPLC-RI, os ácidos gordos por GC-FID, os ácidos orgânicos por HPLC-PDA e os tocoferois por HPLC-fluorescência. De acordo com os resultados obtidos foi evidente a preservação dos ácidos gordos, dos vitâmeros γ- e δ-tocoferol, da frutose, trealose e dos ácidos quínico e shikímico. Em particular, a dose de 1 kGy manteve o teor em α-tocoferol e em ácidos oxálico e málico, enquanto que a dose de 10 kGy diminuiu a concentração de α-tocoferol, glucose, sacarose e ácidos oxálico e málico. Deste modo e numa avaliação geral, 1 kGy seria a dose recomendada para manter o perfil químico relativo a estas moléculas no Gingko biloba L.
Resumo:
O nitrogênio e potássio são os nutrientes requeridos em maiores quantidades pelas gramas e no Brasil não se tem informação da quantidade a ser aplicada para se obter a formação de tapete em menor tempo possível. Dois experimentos foram instalados em vasos em casa de vegetação, com o objetivo de avaliar o efeito de doses de nitrogênio e de potássio na produção de tapetes de grama esmeralda (Zoysia japonica). O delineamento utilizado para cada experimento foi fatorial com doses de N ou K e épocas de avaliação. Foram aplicadas quatro doses de nitrogênio (0, 200, 400 e 600 kg ha-1) e quatro doses de potássio (0, 100, 200, e 300 kg ha-1). As doses de nitrogênio e potássio foram aplicadas parceladamente em cobertura. O aumento das doses de N influenciou a taxa de cobertura do solo pela grama (TCS) permitindo a formação do tapete com a dose de 408 kg ha-1 de N aos 198 dias após a colheita do tapete anterior, tempo menor quando comparado com as demais doses. A concentração de N na folha e da cor verde da grama foram influenciadas pelas doses de N podendo ser utilizadas para auxiliar na recomendação das doses de N. O aumento das doses de K não influenciou na TCS pela grama, sendo o teor no solo (1,4 mmol c dm-3) suficiente para a produção dos tapetes de grama esmeralda.
Resumo:
Neste trabalho estudou-se a eficiência dos herbicidas Herbipec 500 FL (s.a. Clortolurão) e Dopler Super (s.a. Diclofope-Metilo+Fenoxaprope-P-Etilo+Mefenepir-Dietilo) no controlo, em pós-emergência de infestantes Monocotiledóneas, e na produção de grão e suas componentes, na cultura do trigo mole em sementeira directa, combinando doses inferiores às recomendadas pelos fabricantes. Os ensaios decorreram nos anos agrícolas de 2006/2007 e 2007/2008, na Herdade do Louseiro no concelho de Évora e na Herdade da Revilheira no concelho de Reguengos de Monsaraz, respectivamente. Na experimentação efectuou-se o estudo dos dois herbicidas, com 3 níveis cada, correspondentes a nove tratamentos. O delineamento experimental foi em blocos casualizados com quatro repetições cada. Verificou-se uma maior eficiência no controlo das plantas infestantes de Lolium rigidum Gaud. e de Juncus bufonius L. e, consequentemente, um maior número de grãos e uma produção de grão de trigo elevada com 2 litros ha-l de Herbipec 500 FL e 0,5 litro ha-1 de Dopler Super. ABSTRACT: The purpose of this work was to study the efficiency of the herbicides Herbipec 500 FL (a.i. chlorotoluron) and Dopler Super (a.i. diclofop-methyl + fenoxaprop-P-ethyl + mefenpyr-diethyl) to control grass weeds at post-emergence in no-till bread wheat and consequently to do the evaluation of potential grain yield combining reduced doses to the recommended ones by the manufacturers. The trials were carried out over two growing seasons (2006/2007 and 2007/2008) on the farm "Revilheira" and on a private farm "Louseiro", both in the district of Évora. Trials to study effects of three doses of a two herbicides, with three levels each, corresponding to nine treatments were executed. The experimental design was a randomized block with four replications each. The results showed a great efficiency and grain yield wheat with the mixture with 2 l ha-1 Herbipec 500 FL and 0,5 1 ha-1 Dopler Super to controlling Lolium spp. and Juncus bufonius L..
Resumo:
Os procedimentos médicos imagiológicos com recurso ao uso de radiações ionizantes têm vindo a crescer de ano para ano, contribuindo para um aumento da dose a que está exposta a população em geral. No entanto e apesar de os benefícios serem ainda superiores aos riscos, os princípios de radioproteção exigem que se tenha em linha de conta os cuidados com a proteção radiológica e que se pratiquem procedimentos seguros e com o mínimo de radiação possível. Isto é particularmente importante no caso da Medicina Nuclear (PET e SPECT), visto que a fonte de radiação é interna e continua a irradiar o doente mesmo depois de terminado o exame radiológico em causa. Nesse sentido, este projeto tem como principal objetivo criar um modelo dosimétrico com base em medidas de área retiradas do local de estudo, a fim de se conseguir prever a dose de radiação a que cada utilizador das instalações pode estar sujeito e ajudar a perceber os locais que determinado grupo de indivíduos (profissionais ou doentes) devem evitar. Para retirar as medidas de área foi usado um detetor de débito de dose RadEyeTM B20, que permite detetar com fiabilidade e rapidez taxas de dose de radiação alfa, beta, gama e X. Com recurso a este detetor, fez-se então uma aquisição metódica das medidas em pontos previamente marcados no piso 0 e no piso -1 do ICNAS, considerados os mais importantes pois é nestes que se realiza a circulação dos utentes. No entanto, a aquisição era só uma parte do projeto, visto que foi necessário depois inseri-los num algoritmo de simulação de Monte Carlo em conjunto com uma interface gráfica para se poder obter os cálculos de dose de exposição com uma interação simples e intuitiva com o utilizador. De acordo com as medidas de dose retiradas com recurso ao detetor utilizado, podemos verificar que os locais com mais radiação associada são no piso 0 a radiofarmácia, a sala de espera dos injetados e as salas das câmaras gama. No piso -1 os pontos considerados mais quentes em termos de radiação são a sala da PET/TC e as salas de espera dos doentes injetados. Com os dados retirados construiu-se uma base estatística adequada, sendo inserida num algoritmo construído para se conseguir criar o modelo de simulação para cálculo de doses para diversas trajetórias dos mais variados utilizadores das instalações do Instituto. Este modelo dosimétrico, criado a partir do estudo das medidas de dose retiradas nos pontos selecionados, pode vir a tornar-se útil visto que pode ser utilizado como uma ferramenta de simulação e por conseguinte, conseguir prever a quantidade de radiação a que cada indivíduo está sujeito quando percorrer os diversos locais nos diferentes pisos do ICNAS. Esta pode vir a ser usada em conjunto com as ferramentas de monitorização pessoal, contribuindo assim para reduzir o valor de dose ocupacional de cada utilizador.
Resumo:
O sistema de PET-TC resulta da combinação de duas modalidades de imagem médica: a Tomografia Computorizada (TC), que permite obter imagens anatómicas precisas, e a Tomografia por Emissão de Positrões (PET), que oferece imagens moleculares do corpo humano. Num exame hibrido de PET-TC, para além da exposição interna, o doente é também submetido a uma exposição externa devida à irradiação do mesmo por uma fonte externa, referente à aquisição dos dados de TC. Como tal, o exame de PET-TC tem associado um aumento da exposição para o doente [Huang, 2009], pelo que normalmente os scans de TC são adquiridos com baixa dose [Nunes,2011]. Pretende-se com este trabalho, estabelecer um método capaz de estimar a dose efetiva em exames de corpo inteiro de 18F-FDG PET-TC, uma vez que existem diversos métodos para realizar análise dosimétrica dos exames individuais de PET e de TC, e comparar os valores obtidos com os valores utilizados em outros países. Foram recolhidos dados de 24 pacientes que efetuaram exames de corpo inteiro de PET-TC com 18F-FDG no ICNAS, por questões de saúde e por necessidade própria, com o intuito de estimar a dose efetiva associada a esses exames. Para estimar a dose efetiva referente ao exame de TC recorreu-se ao valor de DLP, fornecido pelo equipamento de TC com controlo de qualidade em dia, e ao método dos coeficicientes de dose efetiva normalizados, proposto pela CE, obtendo-se um valor de dose de 4.75 mSv. A dose efetiva do exame de PET foi calculada com base nos valores da atividade no momento de aquisição das imagens e em coeficientes de dose para a PET, obtendo-se um valor de dose de 4.77 mSv. Concluiu-se que para os pacientes sujeitos ao exame de corpo inteiro de 18F-FDG PET-TC, foi registado um valor de dose de 9.47 mSv de dose efetiva. Este valor de dose efetiva para os exames de PET-TC é significativamente mais baixo comparativamente aos valores registados em vários estudos internacionais (13.65 mSv, 14.3 mSv, 18.85 mSv, 24.8 mSv, 25 mSv, 32.18 mSv), dos quais apenas no estudo de Brix um dos hospitais estudados regista um valor ligeiramente inferior, de 8.5 mSv. Com este estudo foi possível determinar o valor de exposição à radiação a que os pacientes do ICNAS se encontram sujeitos em exames de corpo inteiro de 18F-FDG PET-TC considerando as duas modalidades de imagem médica.