941 resultados para Dose diária recomendada


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It currently is unknown whether creatine supplementation is safe for people with or at risk of kidney disease. We report on the short-term effects of creatine supplementation on kidney function in a young man with a single kidney and mildly decreased glomerular filtration rate (GFR). A 20-year-old man who had undergone unilateral nephrectomy and presented with mildly decreased GFR without kidney damage underwent a trial with 35 days of creatine supplementation (20 g/d for 5 days followed by 5 g/d for the next 30 days) and had his kidney function monitored. After the intervention, (51)Cr-EDTA clearance (pre, 81.6 mL/min/1.73 m(2); post, 82.0 mL/min/1.73 m(2)), proteinuria (protein excretion: pre, 130 mg/d; post, 120 mg/d), and electrolyte levels were unchanged. Albuminuria, serum urea level, and estimated creatinine clearance were decreased (pre, 4.6 mg/d; post, 2.9 mg/d; pre, 37 mg/d; post, 28 mg/dL; and pre, 88 mL/min/1.73 m(2); post, 71 mL/min/1.73 m(2), respectively), whereas serum creatinine level was slightly increased (pre, 1.03 mg/dL; post, 1.27 mg/dL), falsely suggesting kidney function impairment. This prospective report suggests that short-term creatine supplementation may not affect kidney function in an individual with a single kidney, mild decreased GFR, and ingesting a high-protein diet (ie, 2.8 g/kg/d). This finding has great relevance considering that creatine-induced kidney disease has been a growing concern, even for healthy people. Am J Kidney Dis 55: e7-e9. (C) 2010 by the National Kidney Foundation, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the scattered X-ray beams produced by a mammography unit with a Mo/Mo, Mo/Rh and W/Rh anode/filter combinations were applied in the evaluation of the Hp(10, 0) and mean conversion coefficients from air kerma to the personal dose equivalent ((C) over barH(p(10,0 degrees))). The higher values of H(p)(10,0 degrees) are related to the Mo/Rh combination whereas the lower ones are for the W/Rh target/filter. (C) over barH(p(10,0 degrees)) values are in the range 0.19-0.54 Sv/Gy, where the higher values comprise the W/Rh combination. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In medical processes where ionizing radiation is used, dose planning and dose delivery are the key elements to patient safety and treatment success, particularly, when the delivered dose in a single session of treatment can be an order of magnitude higher than the regular doses of radiotherapy. Therefore, the radiation dose should be well defined and precisely delivered to the target while minimizing radiation exposure to surrounding normal tissues [1]. Several methods have been proposed to obtain three-dimensional (3-D) dose distribution [2, 3]. In this paper, we propose an alternative method, which can be easily implemented in any stereotactic radiosurgery center with a magnetic resonance imaging (MRI) facility. A phantom with or without scattering centers filled with Fricke gel solution is irradiated with Gamma Knife(A (R)) system at a chosen spot. The phantom can be a replica of a human organ such as head, breast or any other organ. It can even be constructed from a real 3-D MR image of an organ of a patient using a computer-aided construction and irradiated at a specific region corresponding to the tumor position determined by MRI. The spin-lattice relaxation time T (1) of different parts of the irradiated phantom is determined by localized spectroscopy. The T (1)-weighted phantom images are used to correlate the image pixels intensity to the absorbed dose and consequently a 3-D dose distribution with a high resolution is obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper is to report the sensitization of the TL peak appearing at 270 degrees C in the glow curve of natural quartz by using the combined effect of heat-treatments and irradiation with high gamma doses. For this, thirty discs with 6 x 1 mm(2) were prepared from plates parallell to a rhombolledral crystal face. The specimens were separated into four lots according to its TL read out between 160 and 320 degrees C. One lot was submitted to gamma doses of Co-60 radiation starting at 2 kGy and going up until a cumulative dose of 25 kGy. The other three lots were initially heal-treated at 500, 800 and 1000 degrees C and then irradiated with a single dose of 25kGy. The TL response of each lot was determined as a function of test-doses ranging from 0.1 to 30 mGy. As a result, it was observed that heat-treatments themselves did not produce the strong peak at 270 degrees C that was observed after the administration of high gamma doses. This peak is associated with the optical absorption band appearing at 470 rim which is due to the formation of [AlO4]degrees acting as electron-hole recombination centers. The formation of the 270 degrees C peak was preliminary analyzed in relation to aluminum- and oxygen-vacancy-related centers found in crystalline quartz. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A survey of pediatric radiological examinations was carried out in a reference pediatric hospital of the city of Sao Paulo. in order to investigate the doses to children undergoing conventional X-ray examinations. The results showed that the majority of pediatric patients are below 4 years, and that about 80% of the examinations correspond to chest projections. Doses to typical radiological examinations were measured in vivo with thermoluminescent dosimeters (LiF: Mg, Ti and LiF: Mg, Cu, P) attached to the skin of the children to determine entrance surface dose (ESD). Also homogeneous phantoms were used to obtain ESD to younger children, because the technique uses a so small kVp that the dosimeters would produce an artifact image in the patient radiograph. Four kinds of pediatric examinations were investigated: three conventional examinations (chest, skull and abdomen) and a fluoroscopic procedure (barium swallow). Relevant information about kVp and mAs values used in the examinations was collected, and we discuss how these parameters can affect the ESD. The ESD values measured in this work are compared to reference levels published by the European Commission for pediatric patients. The results obtained (third-quartile of the ESD distribution) for chest AP examinations in three age groups were: 0.056 mGy (2-4 years old); 0,068 mGy (5-9 years old)-. 0.069 mGy (10-15 years old). All of them are below the European reference level (0.100mGy). ESD values measured to the older age group in skull and abdomen AP radiographs (mean values 3.44 and 1.20mGy, respectively) are above the European reference levels (1.5mGy to skull and 1.0 mGy to abdomen). ESD values measured in the barium swallow examination reached 10 mGy in skin regions corresponding to thyroid and esophagus. It was noticed during this survey that some technicians use, improperly, X-ray fluoroscopy in conventional examinations to help them in positioning the patient. The results presented here are a preliminary survey of doses in pediatric radiological examinations and they show that it is necessary to investigate the technical parameters to perform the radiographs. to introduce practices to control pediatric patient`s doses and to improve the personnel training to perform a pediatric examination. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to validate the Geant4 toolkit for dosimetry applications, simulations were performed to calculate conversion coefficients h(10, alpha) from air kerma free-in-air to personal dose equivalent Hp(10, a). The simulations consisted of two parts: the production of X-rays with radiation qualities of narrow and wide spectra, and the interaction of radiation with ICRU tissue-equivalent and ISO water slab phantoms. The half-value layers of the X-ray spectra obtained by simulation were compared with experimental results. Mean energy, spectral resolution, half-value layers and conversion coefficients were compared with ISO reference values. The good agreement between results from simulation and reference data shows that the Geant4 is suitable for dosimetry applications which involve photons with energies in the range of ten to a few hundreds of keV. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the effects of low-dose therapeutic ionizing radiation on different aesthetic dental materials. Forty five specimens (n = 45) of three different aesthetic restorative materials were prepared and randomly divided into five groups: G1 (control group); G2, G3, G4, G5 experimental groups irradiated respectively with 0.25, 0.50, 0.75, and 1.00 Gy of gamma radiation by the (60)Co teletherapy machine. Chemical analyses were performed using a FT-IR Nicolet 520 spectrophotometer with reflectance diffuse technique. Even a minimal exposition at ionizing radiation in therapeutic doses can provide chemical changes on light-cured composite resins. The three studied restorative materials showed changes after exposure at gamma radiation, however the increase of the radiation dose did not contribute to an increase in this effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to design a set of rules for levodopa infusion dose adjustment in Parkinson’s disease based on a simulation experiments. Using this simulator, optimal infusions dose in different conditions were calculated. There are seven conditions (-3 to +3)appearing in a rating scale for Parkinson’s disease patients. By finding mean of the differences between conditions and optimal dose, two sets of rules were designed. The set of rules was optimized by several testing. Usefulness for optimizing the titration procedure of new infusion patients based on rule-based reasoning was investigated. Results show that both of the number of the steps and the errors for finding optimal dose was shorten by new rules. At last, the dose predicted with new rules well on each single occasion of majority of patients in simulation experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução. Embora muitas crianças com câncer possam ser curadas, um número significativo têm resposta insatisfatória por ineficácia da terapêutica tornando necessário identificar agentes anticâncer mais efetivos contra tumores refratários ou recaídos. Estudos com Etoposide revelaram uma clara relação entre o tempo de exposição e os seus efeitos citotóxicos, mostrando resultados superiores com o uso de doses fracionadas quando comparado ao uso de uma dose única. Estudos de farmacocinética sugerem que as concentrações plasmáticas ativas de Etoposide se situa entre 1 e 5 μg/ml e que níveis acima de 5 μg/ml determinam uma mielotoxicidade importante. O Etoposide apresenta um bom espectro antitumoral mesmo em pacientes que já foram tratados por via parenteral e uma adequada biodisponibilidade pela via oral, podendo ser administrado com segurança em regime ambulatorial. Portanto, torna-se atraente a busca de esquemas de administração deste agente, os quais produzem níveis de concentração plasmática seguras pelo maior tempo possível. Objetivos. Os objetivos deste estudo de fase I é avaliar o perfil de toxicidade, a toxicidade dose-limitante, a dose máxima tolerada, a farmacocinética plasmática e a dose segura do Etoposide oral recomendada para estudos de fase II em pacientes pediátricos portadores de tumor sólido refratário. Materiais e Métodos. Todos os pacientes eram portadores de tumor sólido não responsivo aos tratamentos estabelecidos. A dose inicial do Etoposide foi de 20mg/m2/dose, a cada 8 horas durante 14 dias seguido de um intervalo de 7 dias antes de iniciar o próximo ciclo. A farmacocinética plasmática do Etoposide foi estudada durante o primeiro dia de tratamento e os níveis de Etoposide determinados pelo método de HPLC. Resultados. Dezessete pacientes foram incluídos no estudo, sendo que em 13 foram realizados o estudo de farmacocinética. O número total de cursos de quimioterapia foi de 64. Nove pacientes foram incluídos no Nível de dose I, sendo que leucopenia grau 2-3 foi observada em 5. A dose foi então escalonada para 25 mg/m2 (Nível de dose II) e fornecida a 8 pacientes subsequentes o que determinou leucopenia grau 3-4 em 4 deles. Este Nível de dose foi então considerado como DMT (Dose Máxima Tolerada). A TDL foi neutropenia. As concentrações plasmáticas máximas de Etoposide nos pacientes incluídos no Nível de dose I e II foram de 2,97 e 8,59 μg/ml, respectivamente, e os níveis da droga >1 μg/ml foi mantido durante cerca de 6,3 horas após a administração da droga em ambos os níveis de dose. Resposta parcial foi observada em 1 paciente e 4 apresentaram doença estável. Conclusões. A administração prolongada de Etoposide oral nas doses de 20 mg/m2 a cada 8 horas durante 14 dias consecutivos, seguidos de 7 dias de repouso, foi bem tolerada e determinou uma toxicidade manejável em crianças e adolescentes portadores de doenças malignas refratárias. A dose de 20 mg/m2 aparentemente preencheu os requisitos farmacocinéticos que objetivam melhorar o índice terapêutico do Etoposide, ou seja, a obtenção de níveis plasmáticos citotóxicos sustentados e abaixo do limite de toxicidade clínica da droga.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cintilografia com radioisótopos em repouso tem despertado muito interesse nos últimos anos para pesquisa da viabilidade miocárdica na disfunção isquêmica avançada do VE, porque esta pode ser reversível e porque há melhora prognóstica neste contexto. O objetivo desse trabalho é buscar identificar a acurácia da cintilografia tomográfica Tc-99m-Sestamibi, sob a infusão de dobutamina em baixa dose. Foram protocolados trinta pacientes que sofreram um infarto do miocárdio com padrão “Q”, com dissinergia ao ecocardiograma, e submetidos a estudos perfusionais em dias diferentes, com Tc-99m-Sestamibi − dobutamina e Tl-201 em repouso-redistribuição 4 horas, usado como padrão ouro. Não ocorreram complicações com nenhum paciente submetido ao protocolo do estudo. Os resultados revelaram: sensibilidade = 85%, especificidade = 87%, valor preditivo positivo = 96%, valor preditivo negativo = 65 % e acurácia de = 85,2%. A razão de probabilidade positiva foi de 6,68 e a razão de probabilidade negativa de 0,17. Confrontando-se nossos dados com uma metanálise de resultados para o Tc-99m-Sestamibi em repouso, a sensibilidade no presente estudo foi 85% vs. 81% e a especificidade de 87% vs. 60%. Em relação aos dados da literatura para Tl-201: 85% vs. 90% e 87% vs. 54%, sensibilidade e especificidade, respectivamente. Em conclusão, o Tc-99m-Sestamibi sob a infusão de dobutamina parece ser um método promissor para detectar viabilidade superior a esta modalidade de cintilografia em repouso, com valores preditivos comparáveis à literatura disponível para esse mesmo método: 85,2% vs. 87%, 96% vs. 90% e 65% vs. 83%, para acurácia, valor preditivo positivo e valor preditivo negativo, respectivamente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A alface é a hortaliça folhosa mais consumida no mundo. É uma rica fonte de vitaminas e sais minerais que está presente no cardápio diário de grande parte da população brasileira. O nitrogênio é o nutriente mais importante para a produção de alface. O excesso ou falta desse nutriente acarretam queda na produção e problemas de qualidade nutritiva, por excesso de nitrato. A dose recomendada de nitrogênio varia muito entre autores e órgãos oficiais. Uma parte do nitrogênio aplicado ao solo é perdida por lixiviação, contaminando os mananciais de água. Devido a isso é recomendada a sua aplicação em diversas etapas, cujo número também é variável nas recomendações. Este trabalho teve por objetivo determinar qual a dose de nitrogênio e seu modo de aplicação que proporcionam a maior produção, sem comprometer a qualidade da alface do tipo “lisa”, nas condições de clima e solo do município de Eldorado do Sul, região da Grande Porto Alegre, RS. Foram realizados dois estudos, um testando doses crescentes de nitrogênio sob a forma de uréia e o outro testando o parcelamento em diversas épocas do cultivo. Foram avaliados a produção de matéria fresca e seca, os teores de nitrogênio, amônio e nitrato no tecido seco, a extração e a eficiência do uso do fertilizante. Os resultados revelam que a dose de 200 kgha-1 foi a que proporcionou maior rendimento da cultura e que a dose de 400 kgha-1 diminui a produção. A extração de nitrogênio foi da ordem de 35,7 kgha-1 e os teores de nitrogênio, amônio e nitrato foram respectivamente de 2,45%; 651,7 mg.kg-1 e 153,6 mg.kg-1. O teor de nitrato na alface foi muito menor do que o considerado prejudicial a saúde humana. A eficiência do uso do fertilizante foi de 12,06% quando aplicado 200 kgha-1 de N em 3 épocas. A eficiência do uso do adubo foi aumentada em 26,35% com o parcelamento em 4 doses iguais de 50 kg ha-1, aplicadas no plantio e aos 15, 30 e 45 dias após, sem alterar a qualidade visual e nutricional da alface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A atrazina (ATZ) foi utilizada em experimentos de laboratório para estudos de mineralização e dessorção em amostras de Argissolo Vermelho (PV) e Vertissolo Ebânico (VE), sob campo nativo, com o intuito de identificar os atributos do solo que afetam estes processos. A influência da umidade do solo sobre a atividade microbiana foi avaliada variando-se os teores de umidade em 20, 40, 65 e 85% da capacidade de água disponível do solo (CAD) e aplicando-se 1,5 kg de princípio ativo ha-1 (menor dose recomendada (DR)). Para a avaliação do efeito das doses do herbicida ATZ sobre a atividade microbiana e sobre a taxa de degradação do herbicida foram feitas aplicações de 1x, 2x, 4x, 7x e 10x a DR. Na avaliação do efeito da matéria orgânica sobre a atividade microbiana e sobre a taxa de degradação da ATZ foi feita a aplicação de 10x a DR. Num estudo adicional foram testados quatro métodos de desinfestação de solos (fumigação, tindalização, autoclavagem e irradiação em forno de microondas). A determinação da ATZ na solução foi feita por cromatografia gasosa em extratos de metanol. A atividade microbiana foi monitorada pela evolução de CO2 e a microbiota foi avaliada pela contagem de unidades formadoras de colônias Os resultados indicam que a população microbiana apresenta maior atividade entre 65 e 85% de umidade da CAD e que o aumento das doses de aplicação da ATZ não provoca alterações relevantes na atividade microbiana. Aproximadamente 70% do herbicida aplicado fica sorvido ao solo, independentemente de dose de ATZ aplicada e da classe de solo estudada (PV e VE). As taxas de degradação da ATZ lábil foram baixas e dependentes de doses e tipos de solos, sendo maiores em doses mais elevadas e em solos com maior teor de C. Dentre os métodos de desinfestação, a irradiação em forno de microondas foi o mais adequado, uma vez que apresentou um comportamento similar à testemunha quanto à sorção do herbicida e foi eficiente na redução da população microbiana do solo.