Conversion coefficients from air kerma to personal dose equivalent in mammography


Autoria(s): KUNZEL, R.; LEVENHAGEN, R. S.; Herdade, Silvio Bruni
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

20/10/2012

20/10/2012

2010

Resumo

In this work, the scattered X-ray beams produced by a mammography unit with a Mo/Mo, Mo/Rh and W/Rh anode/filter combinations were applied in the evaluation of the Hp(10, 0) and mean conversion coefficients from air kerma to the personal dose equivalent ((C) over barH(p(10,0 degrees))). The higher values of H(p)(10,0 degrees) are related to the Mo/Rh combination whereas the lower ones are for the W/Rh target/filter. (C) over barH(p(10,0 degrees)) values are in the range 0.19-0.54 Sv/Gy, where the higher values comprise the W/Rh combination. (C) 2009 Elsevier Ltd. All rights reserved.

Brazilian Agency FAPESP (Fundacao de Amparo Pesquisa do Estado de Sao Paulo)[01/12032-7]

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Identificador

RADIATION PHYSICS AND CHEMISTRY, v.79, n.5, p.594-596, 2010

0969-806X

http://producao.usp.br/handle/BDPI/29116

10.1016/j.radphyschem.2009.12.012

http://dx.doi.org/10.1016/j.radphyschem.2009.12.012

Idioma(s)

eng

Publicador

PERGAMON-ELSEVIER SCIENCE LTD

Relação

Radiation Physics and Chemistry

Direitos

closedAccess

Copyright PERGAMON-ELSEVIER SCIENCE LTD

Palavras-Chave #Mammography #Scattered radiation #Personal dose equivalent #Effective dose #X-RAY-SPECTRA #Chemistry, Physical #Nuclear Science & Technology #Physics, Atomic, Molecular & Chemical
Tipo

article

original article