Gamma Knife(A (R)) 3-D Dose Distribution Mapping by Magnetic Resonance Imaging


Autoria(s): Rodríguez, Hernán Joel Cervantes; Cavinato, Christianne Cobello; Rodrigues, Letícia Lucente Campos; Rabbani, Said Rahnamaye
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

20/10/2012

20/10/2012

2010

Resumo

In medical processes where ionizing radiation is used, dose planning and dose delivery are the key elements to patient safety and treatment success, particularly, when the delivered dose in a single session of treatment can be an order of magnitude higher than the regular doses of radiotherapy. Therefore, the radiation dose should be well defined and precisely delivered to the target while minimizing radiation exposure to surrounding normal tissues [1]. Several methods have been proposed to obtain three-dimensional (3-D) dose distribution [2, 3]. In this paper, we propose an alternative method, which can be easily implemented in any stereotactic radiosurgery center with a magnetic resonance imaging (MRI) facility. A phantom with or without scattering centers filled with Fricke gel solution is irradiated with Gamma Knife(A (R)) system at a chosen spot. The phantom can be a replica of a human organ such as head, breast or any other organ. It can even be constructed from a real 3-D MR image of an organ of a patient using a computer-aided construction and irradiated at a specific region corresponding to the tumor position determined by MRI. The spin-lattice relaxation time T (1) of different parts of the irradiated phantom is determined by localized spectroscopy. The T (1)-weighted phantom images are used to correlate the image pixels intensity to the absorbed dose and consequently a 3-D dose distribution with a high resolution is obtained.

FAPESP Fundacao de Amparo a Pesquisa do Estado de Sao Paulo

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

CNPq Conselho Nacional de Desenvolvimento Cientifico e Tecnologico

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Identificador

APPLIED MAGNETIC RESONANCE, v.39, n.4, p.357-364, 2010

0937-9347

http://producao.usp.br/handle/BDPI/29178

10.1007/s00723-010-0166-4

http://dx.doi.org/10.1007/s00723-010-0166-4

Idioma(s)

eng

Publicador

SPRINGER WIEN

Relação

Applied Magnetic Resonance

Direitos

restrictedAccess

Copyright SPRINGER WIEN

Palavras-Chave #STEREOTAXIC RADIOSURGERY #POLYMER-GEL #DOSIMETRY #Physics, Atomic, Molecular & Chemical #Spectroscopy
Tipo

article

original article

publishedVersion