998 resultados para Anttila, Elina
Resumo:
The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
Commissioning studies of the CMS hadron calorimeter have identified sporadic uncharacteristic noise and a small number of malfunctioning calorimeter channels. Algorithms have been developed to identify and address these problems in the data. The methods have been tested on cosmic ray muon data, calorimeter noise data, and single beam data collected with CMS in 2008. The noise rejection algorithms can be applied to LHC collision data at the trigger level or in the offline analysis. The application of the algorithms at the trigger level is shown to remove 90% of noise events with fake missing transverse energy above 100 GeV, which is sufficient for the CMS physics trigger operation. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 μm, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47μm to 243μm. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 μm and 30-200 μrad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340-590 μm based on comparisons with independent photogrammetry measurements. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS detector is designed around a large 4 T superconducting solenoid, enclosed in a 12 000-tonne steel return yoke. A detailed map of the magnetic field is required for the accurate simulation and reconstruction of physics events in the CMS detector, not only in the inner tracking region inside the solenoid but also in the large and complex structure of the steel yoke, which is instrumented with muon chambers. Using a large sample of cosmic muon events collected by CMS in 2008, the field in the steel of the barrel yoke has been determined with a precision of 3 to 8% depending on the location. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The performance of muon reconstruction in CMS is evaluated using a large data sample of cosmic-ray muons recorded in 2008. Efficiencies of various high-level trigger, identification, and reconstruction algorithms have been measured for a broad range of muon momenta, and were found to be in good agreement with expectations from Monte Carlo simulation. The relative momentum resolution for muons crossing the barrel part of the detector is better than 1% at 10 GeV/c and is about 8% at 500 GeV/c, the latter being only a factor of two worse than expected with ideal alignment conditions. Muon charge misassignment ranges from less than 0.01% at 10GeV/c to about 1% at 500 GeV/c. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The Objective Structured Clinical Examination (OSCE) appears to be an effective alternative for assessing not only medical knowledge, but also clinical skills, including effective communication and physical examination skills. The purpose of the current study was to implement an OSCE model in a geriatrics fellowship program and to compare the instrument with traditional essay examination. Seventy first- and second-year geriatric fellows were initially submitted to a traditional essay examination and scored from 0 to 10 by a faculty member. The same fellows subsequently underwent an OSCE with eight 10-minute stations covering a wide range of essential aspects of geriatric knowledge. Each OSCE station had an examiner responsible for its evaluation according to a predefined checklist. Checklist items were classified for analysis purposes as clinical knowledge items (CKI) and communication skills items (CSI); fellow responses were scored from 0 to 10.Although essay examinations took from 30 to 45 minutes to complete, 180200 minutes were required to evaluate fellows using the proposed OSCE method. Fellows scored an average of 6.2 +/- 1.2 on the traditional essay examination and 6.6 +/- 1.0 on the OSCE (P < .001). Subanalyses of OSCE scores indicated that average performance on CKI was lower than the average on CSI (6.4 +/- 1.1 vs. 8.4 +/- 1.1; P < .001). Fellow performance on the essay examination was similar to their performance on CKI (P = .13). Second-year fellows performed better than first-year fellows on the essay examination (P < .001) and CKI (P = .05), but not on CSI (P = .25).The OSCE was successfully implemented as an educational strategy during a geriatrics fellowship program. Combining different testing modalities may provide the best assessment of competence for various domains of knowledge, skills, and behavior.
Resumo:
The European Position Paper on Rhinosinusitis and Nasal Polyps 2012 is the update of similar evidence based position papers published in 2005 and 2007. The document contains chapters on definitions and classification, we now also propose definitions for 'difficult to treat' rhinosinusitis, control of disease and better definitions for rhinosinusitis in children. More emphasis is placed on the diagnosis and treatment of acute rhinosinusitis. Throughout the document the terms chronic rhinosinusitis without nasal polyps (CRSsNP) and chronic rhinosinusitis with nasal polyps (CRSwNP) are used to further point out differences in pathophysiology and treatment of these two entities. There are extensive chapters on epidemiology and predisposing factors, inflammatory mechanisms, (differential) diagnosis of facial pain, genetics, cystic fibrosis, aspirin exacerbated respiratory disease, immunodeficiencies, allergic fungal rhinosinusitis and the relationship between the upper and lower airways. The chapters on paediatric acute and chronic rhinosinusitis are totally rewritten. Last but not least all available evidence for management of acute rhinosinusitis and chronic rhinosinusitis with or without nasal polyps in adults and children is analyzed and presented and management schemes based on the evidence are proposed. This executive summary for otorhinolaryngologists focuses on the most important changes and issues for otorhinolaryngologists.
Resumo:
Övervikt och fetma har utvecklats till ett stort problem i dagens samhälle. Patienter som lider av schizofreni är speciellt drabbade. Dessa patienters medicinska behandling mot sjukdomens symtom har en negativ inverkan på vikten samtidigt som den har en inverkan på deras livskvalité. Syftet med denna litteraturstudie var att belysa omvårdnadsåtgärder samt livskvalité hos patienter som lider av schizofreni samt viktproblem och som undergår behandling med antipsykotiska läkemedel. Metoden bestod av en systematisk litteraturstudie där 13 artiklar av kvantitativ ansats som värderades och analyserades. Resultatet av litteraturstudien visade att det fanns viktminskningsinterventioner att tillgå vid viktökning hos patienter som lider av schizofreni. Livskvalitén påverkades negativt på grund utav viktökning men även positivt i den meningen att den mentala hälsan förbättrades av den antipsykotiska medicineringen. Diskussionen grundade sig på att dessa patienter kunde uppleva två olika effekter av viktökning. Deras mentala hälsa förbättrades när de tog sin medicin på ett adekvat sätt och då ökade i vikt, samtidigt som de upplevde en försämrad livskvalité. Viktminskningsinterventioner var möjliga att genomföra vid övervikt hos patienter som lider av schizofreni och var av vikt för dessa patienters allmänna hälsostatus. Sjuksköterskans roll är att belysa detta problem samt initiera till dessa interventioner eftersom omvårdnaden är sjuksköterskans ansvarsområde.