Performance and operation of the CMS electromagnetic calorimeter
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
27/05/2014
27/05/2014
01/12/2010
|
Resumo |
The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented. © 2010 IOP Publishing Ltd and SISSA. |
Identificador |
http://dx.doi.org/10.1088/1748-0221/5/03/T03010 Journal of Instrumentation, v. 5, n. 3, 2010. 1748-0221 http://hdl.handle.net/11449/72019 10.1088/1748-0221/5/03/T03010 2-s2.0-79953281768 2-s2.0-79953281768.pdf |
Idioma(s) |
eng |
Relação |
Journal of Instrumentation |
Direitos |
openAccess |
Tipo |
info:eu-repo/semantics/article |