Performance of CMS hadron calorimeter timing and synchronization using test beam, cosmic ray, and LHC beam data
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
27/05/2014
27/05/2014
01/12/2010
|
Resumo |
This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns. © 2010 IOP Publishing Ltd and SISSA. |
Identificador |
http://dx.doi.org/10.1088/1748-0221/5/03/T03013 Journal of Instrumentation, v. 5, n. 3, 2010. 1748-0221 http://hdl.handle.net/11449/72022 10.1088/1748-0221/5/03/T03013 2-s2.0-79951828670 2-s2.0-79951828670.pdf |
Idioma(s) |
eng |
Relação |
Journal of Instrumentation |
Direitos |
openAccess |
Palavras-Chave | #Calorimeters #Large detector systems for particle and astroparticle physics |
Tipo |