932 resultados para mini-screws


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Alpha thalassemia, the most common monogenic disorder in the world, is characterized by deletions of one (+-thalassemia) or both alpha genes (0-thalassemia) located on human chromosome 16 (16p13.3). The most common case of +-thalassemia is a deletion of 3.7 kb of DNA (-3.7 deletion). It is most prevalent in African and Middle East regions. In the few studies carried out in Brazilian population -3.7 deletion was the most common deletion, mainly in African descendants. This study was conducted to determine the prevalence of +- thalassemia (deletion 3.7kb) in adult population from Rio Grande do Norte. We obtained blood samples from 713 unrelated individuals of both genders, aged between 18 and 59 years old. All individuals were born in Rio Grande do Norte. The hematological indices were obtained in an automatic cell counter (Micros 60, ABX Diagnostics). The hemoglobin measurement (A2 and Fetal hemoglobin) and the profile confirmation were carried out by high performance liquid chromatography (HPLC) methodology. Genomic DNA was obtained from peripheral blood leukocytes using Illustra Blood GenomicPrep Mini Spin kit and -3.7 deletion was investigated by PCR. Among the 713 individuals studied, 80 (11,2%) presented +- thalassemia: 79 (11,1%) were heterozygous and 1 (0,1%) homozygous for the -3.7 deletion. Considering the ethnic group, negroes showed the greatest prevalence of +-thalassemia (12,5%), followed by mulattoes (12,3%) and caucasian (9,6%). Statistical comparison of hematological parameters between normal individuals and heterozygous to +-thalassemia showed significant differences in RBC (p<0,001), MCV (p<0,001), MCH (p<0,001), Hb A2 (p=0,007) as well as female hemoglobin concentration (p=0,003). This is one of the first studies to research +-thalassemia in general population of Rio Grande do Norte state and these results attest the importance of investigation of this condition to define the etiology of microcytosis and hypochromia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: To estimate the prevalence and correlates of cognitive impairment (CI) among the elderly in a general hospital. Methods: A cross-sectional study, including 200 Brazilian inpatients aged 60 years or over, using the Mini Mental State Examination to evaluate CI (dependent variable), and the Geriatric Depression Scale and the Katz and Lawton Index to evaluate basic (BADL) and instrumental activities of daily living (IADL). Results: 56% were women, 29% were dependent for BADL and 77.5% for IADL. The prevalence of CI was 29% and, in the logistic regression, it remained associated with higher age (1 74 years old), number of previous hospitalizations (1 3) and dependency for BADL (being dependent raised the odds of being cognitively impaired). Conclusions: It is essential to train the hospital staff to properly assist these patients, and to orient and support their caregivers. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This study aims to evaluate the prevalence of depressive symptoms and associated factors among elderly hospital inpatients.Methods: A cross-sectional study evaluated 189 participants using the Geriatric Depression Scale, the Mini-mental State Examination and the Katz and Lawton Index, to assess dependence regarding activities of daily living (ADL).Results: Most of the participants were women, aged between 60 and 92 years, with low levels of educational attainment and personal income, and non-qualified occupations. The prevalence of depressive symptoms was 56%, but only 3% had a psychiatric diagnosis registered in their medical records. Univariate analysis showed significant associations between depressive symptoms and low educational level and income, marital status, number of hospitalizations in the previous year, cognitive decline, dependence regarding basic and instrumental ADL, and death. After logistic regression, the only variables that remained significantly associated with depression were low educational level, dependence regarding basic ADL, and death.Conclusions: Depressive symptoms were independently associated with low educational level and dependence regarding basic ADL. Hospitalized elderly people with depressive symptoms were more likely to die. It is essential to diagnose and treat depression properly in this population to minimize its negative impacts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: An experimental study was done to assess the ability of the vegetal polymer miniplates and screws to repair defects of the orbital floor.Methods: An artificial standard-sized defect was created in the bony floor of right orbit of 45 albino rabbits. The animals were divided into three experimental groups: control group (G1) involving animals with orbital floor defect and no treatment; titanium group (G2) containing animals with orbital floor defect repaired by titanium miniplates and screws; vegetal polymer group (G3) composed of animals with similar orbital floor defects repaired by vegetal polymer miniplates and screws. Throughout the course of the experiment, the animals were clinically evaluated. At 15, 30 and 60 days after surgery, the animals were killed. They were X-rayed immediately after the floor defect and at the moment of sacrifice. Histological and morphometric evaluation of inflammatory reaction and bone healing was done. Data were statistically evaluated.Results: No implants were extruded. Bone consolidation was similar in G2 and G3 and better than in G1 group animals. Inflammatory reaction was most pronounced in animals of G3 15 days after surgery, and it subsided over time.Conclusion: Vegetal polymer miniplates and screws induces small inflammatory reaction and had the ability to stimulate bone growth with good integration in the orbital floor defect allowing to consider the vegetal polymer adequate option to treat orbital floor defects. Future studies involving long-term follow-up and biomechanical tests to evaluate material resistance to traction are needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two birds were presented with malunion fractures. The first was a young toco toucan (Ramphastos toco) with malunion of the tarsometatarsus that was treated by an opening-corrective osteotomy and an acrylic-pin external skeletal fixator (type II) to stabilize the osteotomy. The second bird was m adult southern caracara (Caracara plancus) with radial and ulnar malunion that was treated by closing-wedge osteotomies. Stabilization of the osteotomy sites was accomplished through 1 bone plate fixed cranially on the ulna with 6 cortical screws and an interfragmentary single wire in radius. In both cases, the malunion was corrected, but the manus of the southern caracara was amputated because of carpal joint luxation that induced malposition of the feathers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, trans-physeal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ton clinically healthy two- to three-month-old poodles weighing 1.5-2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the some longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the viability in the effect of open pulled straw (OPS) vitrification procedure of sheep embryos after direct transference. Embryos were produced in vivo and cryopreserved in slow freezing or OPS vitrification. The survival rates of cryopreserved embryos were compared to non-frozen standard pattern. In a first set of experiments, embryos at morula and blastocyst stages were dived in ethylene glycol (1.5 M) and frozen in an automatic freezer. After being thawed, they were directly or indirectly transferred to ewes recipient. A second group of embryos were drawn into OPS and plunged into liquid nitrogen after being exposed at room temperature for 1 min and 45 s in 10% EG plus 10% dimethyl sulphoxide (DMSO), then again for 30 s in 20% EG + 20% DMSO + 0.5 M sucrose. After being warmed, embryos were also directly transferred using a French mini straw as the catheter for the transplantation process or after in vitro dilution of cryoprotectants (two-step-process). No significant difference was observed among fresh, frozen or vitrified embryos on pregnancy rate (50.0%, 38.6% and 55.8%). However, when we evaluated only the direct transference, the pregnancy rate of OPS vitrified embryos was higher than that of frozen embryos (57.1% vs 34.8%) (p = 0.07). In addition, vitrified morulae had a higher pregnancy rate than the one with frozen embryos (64.0% vs 38.9%) (p = 0.07). Finally, our results indicate that OPS vitrification technique in association with direct transference improves the viability of sheep embryos with potential applications to field conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: Recentemente o papilomavírus humano (HPV) tem sido associado à carcinogênese oral. A metodologia empregada na detecção do vírus é uma das maiores causas observadas da grande variabilidade nas taxas de detecção do HPV. Objetivo: Este estudo comparou a sensibilidade de detecção do DNA do HPV em casos de carcinoma epidermoide de lábio utilizando a amplificação do DNA viral por reação em cadeia da polimerase (PCR) ou nPCR. Material e método: Foram utilizadas 33 amostras provenientes de casos de carcinoma epidermoide de lábio. Para as extrações do DNA utilizou-se o sistema QIAamp DNA Mini Kit. Como controle interno utilizou-se o gene da b-globina. Das 33 amostras iniciais, 30 foram positivas para o gene b-globina, sendo utilizadas para detectar o DNA viral. Comparou-se a amplificação do DNA viral pelos métodos da PCR com os oligonucleotídeos MY09/MY11 e nPCR, empregando-se os pares de oligonucleotídeos iniciadores MY09/MY11 e, na segunda etapa, o par GP5+/GP6+. O controle positivo para a presença do DNA do HPV utilizado foi a linhagem de células HeLa e, como controle negativo, a mistura de amplificação sem DNA. A análise dos produtos de PCR e nPCR para HPV foi realizada por eletroforese em gel de poliacrilamida a 8%. Resultados: Utilizando-se o método da PCR, a amplificação do DNA do HPV foi constatada em dois casos. Com a nPCR foi verificada presença de DNA viral em 13 das 30 amostras. Conclusão: Com a utilização da nPCR, a detecção do HPV nos casos estudados aumentou mais de seis vezes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Placa e espaçador de polímero derivado do óleo de mamona (PDOM) (Ricinus communis) foram avaliados clínica, radiográfica e histologicamente na tração linear, fixação e fusão vertebral cervical em 20 cães adultos, sem raça definida, pesando entre 17 e 22kg. Foram sacrificados quatro animais aos 10, 30, 60, 90 e 120 dias de pós-operatório. Após exposição da coluna cervical, por acesso ventral, o disco intervertebral de C4-C5 foi fenestrado e a abordagem ao canal medular foi feita por meio de fenda óssea. Um espaçador de PDOM foi colocado preenchendo o defeito ósseo. Os corpos vertebrais C4-C5 foram fixados com placa do mesmo material, utilizando-se dois parafusos corticais em cada corpo vertebral. Apenas um animal apresentou déficit neurológico no pós-operatório imediato. Radiograficamente as vértebras mostravam-se normais e alinhadas, sem colapso do espaço intervertebral, porém não houve neoformação óssea entre as vértebras. Ao exame mielográfico, não houve compressão da medula espinhal. Os implantes foram efetivos em manter a tração linear e fixação das vértebras cervicais e não ocorreu a fusão vertebral.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this in vitro study was to assess the biomechanical stability of 9 different osteosynthesis methods after sagittal split ramus osteotomy by simulating the masticatory forces and using a 3-point biomechanical test method.Materials and Methods: Forty-five polyurethane hemimandibles with bone-like consistency were randomly assigned to 9 groups (n = 5) and subjected to sagittal split ramus osteotomy. After 4-mm advancement of the distal segment, the bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplate/screw systems: group A, one 4-hole conventional straight miniplate; group B, one 4-hole locking straight miniplate; group C, one 4-hole conventional miniplate and one bicortical screw; group D, one 4-hole locking miniplate and 1 bicortical screw; group E, one 6-hole conventional straight miniplate; group F, one 6-hole locking straight miniplate; group (3: two 4-hole conventional straight miniplates; group H. two 4-hole locking straight miniplates; and group 1, 3 bicortical screws in an inverted-L. pattern. All models were mounted on a base especially constructed for this purpose. Using a 3-point biomechanical test model, the hemimandibles were loaded in compressive strength in an Instron machine (Norwood, MA) until a 3-mm displacement occurred between segments vertically or horizontally. Data were analyzed by analysis of variance and Tukey test (alpha = 1%).Results: The multiparametric comparison of the groups showed a statistically significant difference (P<.01) between groups that used 2 miniplates (groups G and H), 1 miniplate and 1 bicortical screw (groups C and D), and only bicortical screws (group D compared with groups that used only 1 miniplate with 2 screws per segment (groups A and B) and 3 screws per segment (groups E and F).Conclusion: The placement of 2.0-mm-diameter bicortical screws in the retromolar region, associated or not with conventional and locking miniplates with monocortical screws, promoted a better stabilization of bone segments. Locking miniplates presented a better performance in bone fixation in all groups. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:724-730, 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare splinting techniques for impression copings of osseointegrated implants with different angulations.Materials and Methods: Replicas (N = 24) of a metal matrix (control) containing two implants at 90 degrees and 65 degrees in relation to the horizontal surface were obtained by using four impression techniques: Technique 1 (T1), direct technique with square copings without union in open trays; Technique 2 (T2), square copings splinted with dental floss and autopolymerizing acrylic resin; Technique 3 (T3), square copings splinted with dental floss and autopolymerizing acrylic resin, sectioned and splinted again with autopolymerizing acrylic resin; Technique 4 (T4), square copings splinted with prefabricated acrylic resin bar. The impression material was polyether. The replicas were individually scanned to capture the images, which were assessed in a graphic computation program. The program allowed the angulation between the bases of the replicas and the reading screws to be measured. The images of the replicas were compared with the matrix image (control), and the differences in angulations from the control image were calculated. The analysis of variance and the Tukey test for comparisons (p < 0.05) were used for statistical analysis.Results: All groups showed significant differences in the implant angulations in comparison with the control group (p < 0.05). Group T1 showed the highest difference (1.019 degrees) followed by groups T2 (0.747 degrees), T3 (0.516 degrees), and T4 (0.325 degrees), which showed the lowest angular alteration compared to the control group. There were significant differences between inclined and straight implants in all the groups, except in group T4.Conclusions: Based on the results, the splinting of pick-up impression copings is indicated for osseointegrated implant impressions. The square copings splinted with a prefabricated acrylic resin bar presented the best results among the pick-up impression techniques evaluated in this study.