991 resultados para Software CAD 3D para vestuário
Resumo:
Usability is critical to consider an interactive software system successful. Usability testing and evaluation during product development have gained wide acceptance as a strategy to improve product quality. Early introduction of usability perspectives in a product is very important in order to provide a clear visibility of the quality aspects not only for the developers, but also for the testing users as well. However, usability evaluation and testing are not commonly taken into consideration as an essential element of the software development process. Then, this paper exposes a proposal to introduce usability evaluation and testing within a software development through reuse of software artifacts. Additionally, it suggests the introduction of an auditor within the classification of actors for usability tests. It also proposes an improvement of checklists used for heuristics evaluation, adding quantitative and qualitative aspects to them
Resumo:
Three-dimensional segmented echo planar imaging (3D-EPI) is a promising approach for high-resolution functional magnetic resonance imaging, as it provides an increased signal-to-noise ratio (SNR) at similar temporal resolution to traditional multislice 2D-EPI readouts. Recently, the 3D-EPI technique has become more frequently used and it is important to better understand its implications for fMRI. In this study, the temporal SNR characteristics of 3D-EPI with varying numbers of segments are studied. It is shown that, in humans, the temporal variance increases with the number of segments used to form the EPI acquisition and that for segmented acquisitions, the maximum available temporal SNR is reduced compared to single shot acquisitions. This reduction with increased segmentation is not found in phantom data and thus likely due to physiological processes. When operating in the thermal noise dominated regime, fMRI experiments with a motor task revealed that the 3D variant outperforms the 2D-EPI in terms of temporal SNR and sensitivity to detect activated brain regions. Thus, the theoretical SNR advantage of a segmented 3D-EPI sequence for fMRI only exists in a low SNR situation. However, other advantages of 3D-EPI, such as the application of parallel imaging techniques in two dimensions and the low specific absorption rate requirements, may encourage the use of the 3D-EPI sequence for fMRI in situations with higher SNR.
Resumo:
El proyecto trata de convertirse en una herramienta para animadores 3D, tanto para los que hacen películas como para los que modelan videojuegos, que necesiten de un software para simplificar el trabajo que conlleva animar un modelo 3D. Todo sin necesidad de usar trajes especializados. El proyecto, usando Kinect, convertirá los movimientos captados por la cámara y los agregará al modelo, creando una animación basándose en los movimientos reales de una persona.
Resumo:
El proyecto consiste en la creación de un CRM de contact center con canal de telefonía y correo electrónico. Se ha llevado a cabo utilizando software libre. Se integra con centralita telefónica para permitir la realización de llamadas por Voip.
Resumo:
Aquest projecte consisteix en el desenvolupament d’una demo 3D utilitzant exclusivament gràfics procedurals per tal d’avaluar la seva viabilitat en aplicacions més complexes com els videojocs. En aquesta aplicació es genera un terreny aleatori explorable amb vegetació i textures creades proceduralment.
Resumo:
Three-dimensional information is much easier to understand than a set of two-dimensional images. Therefore a layman is thrilled by the pseudo-3D image taken in a scanning electron microscope (SEM) while, when seeing a transmission electron micrograph, his imagination is challenged. First approaches to gain insight in the third dimension were to make serial microtome sections of a region of interest (ROI) and then building a model of the object. Serial microtome sectioning is a tedious and skill-demanding work and therefore seldom done. In the last two decades with the increase of computer power, sophisticated display options, and the development of new instruments, an SEM with a built-in microtome as well as a focused ion beam scanning electron microscope (FIB-SEM), serial sectioning, and 3D analysis has become far easier and faster.Due to the relief like topology of the microtome trimmed block face of resin-embedded tissue, the ROI can be searched in the secondary electron mode, and at the selected spot, the ROI is prepared with the ion beam for 3D analysis. For FIB-SEM tomography, a thin slice is removed with the ion beam and the newly exposed face is imaged with the electron beam, usually by recording the backscattered electrons. The process, also called "slice and view," is repeated until the desired volume is imaged.As FIB-SEM allows 3D imaging of biological fine structure at high resolution of only small volumes, it is crucial to perform slice and view at carefully selected spots. Finding the region of interest is therefore a prerequisite for meaningful imaging. Thin layer plastification of biofilms offers direct access to the original sample surface and allows the selection of an ROI for site-specific FIB-SEM tomography just by its pronounced topographic features.
Resumo:
Proyecto de migración e implantación de software libre en el Ayuntamiento de Palencia.
Resumo:
O presente estudo teve como objetivo desenvolver um sistema de informação em enfermagem com aplicação na assistência de enfermagem e no gerenciamento do serviço. O SisEnf - Sistema de Informação em Enfermagem - é um software livre composto pelo módulo assistencial de enfermagem: histórico, exame clínico e plano de cuidados; o módulo gerencial compõe-se de: escala de serviço, gestão de pessoal, indicadores hospitalares e outros elementos. O sistema foi implementado na Clínica Médica do Hospital Universitário Lauro Wanderley, da Universidade Federal da Paraíba. Tendo em vista a necessidade de aproximação entre usuário e desenvolvedor, e a constante mudança de requisitos funcionais durante o processo iterativo, foi adotado o método do processo unificado. O SisEnf foi desenvolvido sobre plataforma WEB e com emprego de software livre. Portanto, o trabalho desenvolvido procurou auxiliar o processo de trabalho da enfermagem que agora terá oportunidade de incorporar a tecnologia da informação na sua rotina de trabalho.
Resumo:
A traditional photonic-force microscope (PFM) results in huge sets of data, which requires tedious numerical analysis. In this paper, we propose instead an analog signal processor to attain real-time capabilities while retaining the richness of the traditional PFM data. Our system is devoted to intracellular measurements and is fully interactive through the use of a haptic joystick. Using our specialized analog hardware along with a dedicated algorithm, we can extract the full 3D stiffness matrix of the optical trap in real time, including the off-diagonal cross-terms. Our system is also capable of simultaneously recording data for subsequent offline analysis. This allows us to check that a good correlation exists between the classical analysis of stiffness and our real-time measurements. We monitor the PFM beads using an optical microscope. The force-feedback mechanism of the haptic joystick helps us in interactively guiding the bead inside living cells and collecting information from its (possibly anisotropic) environment. The instantaneous stiffness measurements are also displayed in real time on a graphical user interface. The whole system has been built and is operational; here we present early results that confirm the consistency of the real-time measurements with offline computations.
Resumo:
Patient-specific simulations of the hemodynamics in intracranial aneurysms can be constructed by using image-based vascular models and CFD techniques. This work evaluates the impact of the choice of imaging technique on these simulations
Resumo:
This paper presents a new registration algorithm, called Temporal Di eomorphic Free Form Deformation (TDFFD), and its application to motion and strain quanti cation from a sequence of 3D ultrasound (US) images. The originality of our approach resides in enforcing time consistency by representing the 4D velocity eld as the sum of continuous spatiotemporal B-Spline kernels. The spatiotemporal displacement eld is then recovered through forward Eulerian integration of the non-stationary velocity eld. The strain tensor iscomputed locally using the spatial derivatives of the reconstructed displacement eld. The energy functional considered in this paper weighs two terms: the image similarity and a regularization term. The image similarity metric is the sum of squared di erences between the intensities of each frame and a reference one. Any frame in the sequence can be chosen as reference. The regularization term is based on theincompressibility of myocardial tissue. TDFFD was compared to pairwise 3D FFD and 3D+t FFD, bothon displacement and velocity elds, on a set of synthetic 3D US images with di erent noise levels. TDFFDshowed increased robustness to noise compared to these two state-of-the-art algorithms. TDFFD also proved to be more resistant to a reduced temporal resolution when decimating this synthetic sequence. Finally, this synthetic dataset was used to determine optimal settings of the TDFFD algorithm. Subsequently, TDFFDwas applied to a database of cardiac 3D US images of the left ventricle acquired from 9 healthy volunteers and 13 patients treated by Cardiac Resynchronization Therapy (CRT). On healthy cases, uniform strain patterns were observed over all myocardial segments, as physiologically expected. On all CRT patients, theimprovement in synchrony of regional longitudinal strain correlated with CRT clinical outcome as quanti ed by the reduction of end-systolic left ventricular volume at follow-up (6 and 12 months), showing the potential of the proposed algorithm for the assessment of CRT.
Resumo:
Tratando-se de uma era na qual a informação constitui abertura concernente aos benefícios que dela advêm, o campo da informática em enfermagem ganha seu momento. Este estudo teve como objetivo construir um software educativo para o ensino-aprendizado da técnica de cateterismo urinário de demora e comparar a apreensão do conhecimento sobre a técnica de cateterismo urinário de demora antes e após a aplicação de um software educativo. Pesquisa descritiva de abordagem quantitativa tendo como fundamentação pedagógica na construção do software as teorias de Piaget e Vygotsky. Posteriormente, avaliou-se o processo ensino-aprendizagem através de um questionário composto por 10 questões de múltipla escolha, anterior à utilização do software, e o mesmo teste após o manuseio do software, resolvidos por 60 alunos participantes. Os dados obtidos demonstraram significativa contribuição do software após a aplicação do mesmo, sendo bastante útil no processo ensino-aprendizagem.
Resumo:
This paper describes a Computer-Supported Collaborative Learning (CSCL) case study in engineering education carried out within the context of a network management course. The case study shows that the use of two computing tools developed by the authors and based on Free- and Open-Source Software (FOSS) provide significant educational benefits over traditional engineering pedagogical approaches in terms of both concepts and engineering competencies acquisition. First, the Collage authoring tool guides and supports the course teacher in the process of authoring computer-interpretable representations (using the IMS Learning Design standard notation) of effective collaborative pedagogical designs. Besides, the Gridcole system supports the enactment of that design by guiding the students throughout the prescribed sequence of learning activities. The paper introduces the goals and context of the case study, elaborates onhow Collage and Gridcole were employed, describes the applied evaluation methodology, anddiscusses the most significant findings derived from the case study.
Resumo:
PURPOSE: To investigate magnetization transfer (MT) effects as a new source of contrast for imaging and tracking of peripheral foot nerves. MATERIALS AND METHODS: Two sets of 3D spoiled gradient-echo images acquired with and without a saturation pulse were used to generate MT ratio (MTR) maps of 260 μm in-plane resolution for eight volunteers at 3T. Scan parameters were adjusted to minimize signal loss due to T2 dephasing, and a dedicated coil was used to improve the inherently low signal-to-noise ratio of small voxels. Resulting MTR values in foot nerves were compared with those in surrounding muscle tissue. RESULTS: Average MTR values for muscle (45.5 ± 1.4%) and nerve (21.4 ± 3.1%) were significantly different (P < 0.0001). In general, the difference in MTR values was sufficiently large to allow for intensity-based segmentation and tracking of foot nerves in individual subjects. This procedure was termed MT-based 3D visualization. CONCLUSION: The MTR serves as a new source of contrast for imaging of peripheral foot nerves and provides a means for high spatial resolution tracking of these structures. The proposed methodology is directly applicable on standard clinical MR scanners and could be applied to systemic pathologies, such as diabetes.