987 resultados para Area measurement
Resumo:
Dissertação de mestrado integrado em Engenharia Mecânica
Resumo:
Dissertação de Mestrado (Programa Doutoral em Informática)
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.
Resumo:
Dissertação de mestrado em Engenharia Urbana
Resumo:
OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.
Resumo:
OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.
Resumo:
OBJECTIVE: To assess blood pressure measurement by health professionals of a public hospital in São Paulo State. METHODS: Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. RESULTS: Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. CONCLUSION: Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.
Resumo:
OBJECTIVE: We determined the effects of losartan and PD 123319 (antagonists of the AT1 and AT2 angiotensin receptors, respectively), and [Sar¹, Ala8] ANG II (a relatively peptide antagonist of angiotensin receptors) injected into the paraventricular nucleus (PVN) on water and 3% NaCl intake, and the diuretic, natriuretic, and pressor effects induced by administration of angiotensin II (ANG II) into the medial septal area (MSA) of conscious rats. METHODS: Holtzman rats were used . Animals were anesthetized with tribromoethanol (20 mg) per 100 grams of body weight, ip. A stainless steel guide cannula was implanted into the MSA and PVN. All drugs were injected in 0.5-mul volumes for 10-15 seconds. Seven days after brain surgery, water and 3% NaCl intake, urine and sodium excretion, and arterial blood pressure were measured. RESULTS: Losartan (40 nmol) and [Sar¹, Ala8] ANG II (40 nmol) completely eliminated whereas PD 123319 (40 nmol) partially blocked the increase in water and sodium intake and the increase in arterial blood pressure induced by ANG II (10 nmol) injected into the MSA. The PVN administration of PD 123319 and [Sar¹, Ala8] ANG II blocked whereas losartan attenuated the diuresis and natriuresis induced by MSA administration of ANG II. CONCLUSION: MSA involvement with PVN on water and sodium homeostasis and arterial pressure modulation utilizing ANGII receptors is suggested.
Resumo:
Fascicles 1-12, 1753-1906
Resumo:
Suppl. 1906-12
Resumo:
Suppl. prelim. 1913-17
Resumo:
Suppl. 3 1917-33
Resumo:
Suppl. 4 1934-60
Resumo:
Introdução: São escassas as medidas objetivas, válidas e consistentes da função sensoriomotora do complexo articular do ombro (CAO). Objetivos: desenvolvimento e validação de um protocolo de avaliação sensoriomotora do CAO. Materiais e métodos: 40 Sujeitos (16 atletas e 24 não atletas) completaram 6 momentos de teste, 3 por cada um de 2 investigadores. Em cada momento avaliou-se a NPA pelo Biodex System 3, na elevação do braço no plano da omoplata a 80º e 160º, e na rotação externa (RE) a 45º e 80º , bem como o controlo postural do CAO avaliou-se pela plataforma Rsscan. Resultados/Discussão: Todas as variáveis apresentaram estabilidade temporal, exceto os erros a 80º na RE (p=0,021) e 80º no PO (p=0,006), nos atletas, para o Investigador 1, e as componentes do CP nos não atletas, para o investigador 2. Os ICC’s foram globalmente baixos, apresentando valores moderados no grupo de não atletas, para o Investigador 2, no comprimento (0,862) e velocidade média do CP (0,852). Excluindo a área do CP no grupo de não atletas (p=0,030), não houve diferenças significativas nas médias entre observadores. Verificaram-se correlações fortes entre as componentes do CP, mas não ocorreram correlações fortes entre estas e as da NPA. Conclusões: Os resultados poucos consistentes, não permitem retirar conclusões sólidas, impossibilitando assumir o protocolo como fiável e válido na avaliação sensoriomotora do CAO.
Resumo:
El objetivo general de este proyecto estratégico es incorporar una actividad de alto valor agregado como es el diseño de circuitos integrados dentro del segmento de alta tecnología de la cadena productiva nacional. Para ello resulta necesario cumplimentar los siguientes objetivos específicos:• Fortalecer los grupos de investigación y desarrollo que realizan tareas dentro de este área temática, tanto en infraestructura como en recursos humanos; • Fortalecer y desarrollar la Industria Electrónica mediante la incorporación de estas nuevas tecnologías en sus productos; • Representar y asistir a los grupos de diseño locales en la búsqueda de oportunidades para realizar “outsourcing” de diseño para compañías del exterior; • Establecer una primer masa crítica de diseñadores, que funcione como impulsora de la actividad en el medio; • Generar una red a nivel local, donde convivan empresas, universidades y profesionales. La mejora continua en las prestaciones de los productos y en los procesos productivos ha llevado a que la microelectrónica esté presente en los más diversos ámbitos de la actividad humana, con la perspectiva de ir incrementando constantemente su participación. Por eso mismo, un país que pretenda insertarse en el mundo de manera soberana no puede menospreciar la necesidad de incrementar la capacidad de su industria en el área. Los componentes de la Cadena de valor de la ME son los siguientes: • Diseño del circuito, con valor agregado de conocimientos y experiencia del diseñador; • Herramientas de Software de diseño (CAD) con verificación y simulación; • Prototipeo de circuitos y ensayo (testing); • Fabricación de chip en línea; •Encapsulado y testeo. Salvo el primer eslabón, los restantes requieren de una gran inversión en infraestructura, con una permanente actualización. Sin embargo, el Diseño de circuitos es perfectamente abordable en la Argentina, dado que solo requiere de conocimiento y experiencia, y se puede realizar sobre computadoras estándar.