951 resultados para glacier reconstruction
Resumo:
CONTEXT Robot-assisted surgery is increasingly used for radical cystectomy (RC) and urinary reconstruction. Sufficient data have accumulated to allow evidence-based consensus on key issues such as perioperative management, comparative effectiveness on surgical complications, and oncologic short- to midterm outcomes. OBJECTIVE A 2-d conference of experts on RC and urinary reconstruction was organized in Pasadena, California, and the City of Hope Cancer Center in Duarte, California, to systematically review existing peer-reviewed literature on robot-assisted RC (RARC), extended lymphadenectomy, and urinary reconstruction. No commercial support was obtained for the conference. EVIDENCE ACQUISITION A systematic review of the literature was performed in agreement with the PRISMA statement. EVIDENCE SYNTHESIS Systematic literature reviews and individual presentations were discussed, and consensus on all key issues was obtained. Most operative, intermediate-term oncologic, functional, and complication outcomes are similar between open RC (ORC) and RARC. RARC consistently results in less blood loss and a reduced need for transfusion during surgery. RARC generally requires longer operative time than ORC, particularly with intracorporeal reconstruction. Robotic assistance provides ergonomic value for surgeons. Surgeon experience and institutional volume strongly predict favorable outcomes for either open or robotic techniques. CONCLUSIONS RARC appears to be similar to ORC in terms of operative, pathologic, intermediate-term oncologic, complication, and most functional outcomes. RARC consistently results in less blood loss and a reduced need for transfusion during surgery. RARC can be more expensive than ORC, although high procedural volume may attenuate this difference. PATIENT SUMMARY Robot-assisted radical cystectomy (RARC) is an alternative to open surgery for patients with bladder cancer who require removal of their bladder and reconstruction of their urinary tract. RARC appears to be similar to open surgery for most important outcomes such as the rate of complications and intermediate-term cancer-specific survival. Although RARC has some ergonomic advantages for surgeons and may result in less blood loss during surgery, it is more time consuming and may be more expensive than open surgery.
Resumo:
PURPOSE: Many rectal cancer patients undergo abdominoperineal excision worldwide every year. Various procedures to restore perineal (pseudo-) continence, referred to as total anorectal reconstruction, have been proposed. The best technique, however, has not yet been defined. In this study, the different reconstruction techniques with regard to morbidity, functional outcome and quality of life were analysed. Technical and timing issues (i.e. whether the definitive procedure should be performed synchronously or be delayed), oncological safety, economical aspects as well as possible future improvements are further discussed. METHODS: A MEDLINE and EMBASE search was conducted to identify the pertinent multilingual literature between 1989 and 2013. All publications meeting the defined inclusion/exclusion criteria were eligible for analysis. RESULTS: Dynamic graciloplasty, artificial bowel sphincter, circular smooth muscle cuff or gluteoplasty result in median resting and squeezing neo-anal pressures that equate to the measurements found in incontinent patients. However, quality of life was generally stated to be good by patients who had undergone the procedures, despite imperfect continence, faecal evacuation problems and a considerable associated morbidity. Many patients developed an alternative perception for the urge to defecate that decisively improved functional outcome. Theoretical calculations suggested cost-effectiveness of total anorectal reconstruction compared well to life with a permanent colostomy. CONCLUSIONS: Many patients would be highly motivated to have their abdominal replaced by a functional perineal colostomy. Given the considerable morbidity and questionable functional outcome of current reconstruction technique improvements are required. Tissue engineering might be an option to design an anatomically and physiologically matured, and customised continence organ.
Resumo:
Variations of the surface structure and composition of the Au(110) electrode during the formation/lifting of the surface reconstruction and during the surface oxidation/reduction in 0.1 M aqueous sulfuric acid were studied by cyclic voltammetry, scanning tunneling microscopy and shell-isolated nanoparticle enhanced Raman spectroscopy. Annealing of the Au(110) electrode leads to a thermally-induced reconstruction formed by intermixed (1×3) and (1×2) phases. In a 0.1 M H2SO4 solution, the decrease of the potential of the atomically smooth Au(110)-(1×1) surface leads to the formation of a range of structures with increasing surface corrugation. The electrochemical oxidation of the Au(110) surface starts by the formation of anisotropic atomic rows of gold oxide. At higher potentials we observed a disordered structure of the surface gold oxide, similar to the one found for the Au(111) surface.
Resumo:
On Au(111) electrodes, the investigation of ClO4− adsorption is hampered by a simultaneous surface reconstruction. We demonstrate that these two processes can be decoupled in cyclic voltammograms by a proper choice of the scan rate and of the initial potential. Our approach allowed the establishment of a relation between potentials of zero charge for the reconstructed and unreconstructed Au(111) surfaces.
Resumo:
PURPOSE Despite the fact that new and modern short-stems allow bone sparing and saving of soft-tissue and muscles, we still face the challenge of anatomically reconstructing the femoro-acetabular offset and leg length. Therefore a radiological and clinical analysis of a short-stem reconstruction of the femoro-acetabular offset and leg length was performed. METHODS Using an antero-lateral approach, the optimys short-stem (Mathys Ltd, Bettlach, Switzerland) was implanted in 114 consecutive patients in combination with a cementless cup (Fitmore, Zimmer, Indiana, USA; vitamys RM Pressfit, Mathys Ltd, Bettlach, Switzerland). Pre- and postoperative X-rays were done in a standardized technique. In order to better analyse and compare X-ray data a special double coordinate system was developed for measuring femoral- and acetabular offset. Harris hip score was assessed before and six weeks after surgery. Visual analogue scale (VAS) satisfaction, leg length difference and the existence of gluteal muscle insufficiency were also examined. RESULTS Postoperative femoral offset was significantly increased by a mean of 5.8 mm. At the same time cup implantation significantly decreased the acetabular offset by a mean of 3.7 mm, which resulted in an increased combined femoro-acetabular offset of 2.1 mm. Postoperatively, 81.7 % of patients presented with equal leg length. The maximum discrepancy was 10 mm. Clinically, there were no signs of gluteal insufficiency. No luxation occurred during hospitalization. The Harris hip score improved from 47.3 before to 90.1 points already at six weeks after surgery while the mean VAS satisfaction was 9.1. CONCLUSION The analysis showed that loss of femoro-acetabular offset can be reduced with an appropriate stem design. Consequently, a good reconstruction of anatomy and leg length can be achieved. In the early postoperative stage the clinical results are excellent.
Resumo:
OBJECTIVES In this phantom CT study, we investigated whether images reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) with reduced tube voltage and current have equivalent quality. We evaluated the effects of different acquisition and reconstruction parameter settings on image quality and radiation doses. Additionally, patient CT studies were evaluated to confirm our phantom results. METHODS Helical and axial 256 multi-slice computed tomography scans of the phantom (Catphan(®)) were performed with varying tube voltages (80-140kV) and currents (30-200mAs). 198 phantom data sets were reconstructed applying FBP and IR with increasing iterations, and soft and sharp kernels. Further, 25 chest and abdomen CT scans, performed with high and low exposure per patient, were reconstructed with IR and FBP. Two independent observers evaluated image quality and radiation doses of both phantom and patient scans. RESULTS In phantom scans, noise reduction was significantly improved using IR with increasing iterations, independent from tissue, scan-mode, tube-voltage, current, and kernel. IR did not affect high-contrast resolution. Low-contrast resolution was also not negatively affected, but improved in scans with doses <5mGy, although object detectability generally decreased with the lowering of exposure. At comparable image quality levels, CTDIvol was reduced by 26-50% using IR. In patients, applying IR vs. FBP resulted in good to excellent image quality, while tube voltage and current settings could be significantly decreased. CONCLUSIONS Our phantom experiments demonstrate that image quality levels of FBP reconstructions can also be achieved at lower tube voltages and tube currents when applying IR. Our findings could be confirmed in patients revealing the potential of IR to significantly reduce CT radiation doses.
Resumo:
OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.