934 resultados para Necessary optimality conditions of Euler-Lagrange type


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The operation of generalized Marx-type solid-state bipolar modulators is discussed and compared with simplified Marx-derived circuits, to evaluate their capability to deal with various load conditions. A comparative analysis on the number of switches per cell, fiber optic trigger count, losses, and switch hold-off voltages has been made. A circuit topology is obtained as a compromise in terms of operating performance, trigger simplicity, and switching losses. A five-stage laboratory prototype of this circuit has been assembled using 1200 V insulated gate bipolar transistors (IGBTs) and diodes, operating with 1000 V dc input voltage and 1 kHz frequency, giving 5 kV bipolar pulses, with 2.5 mu s pulse width and 5 mu s relaxation time into resistive, capacitive, and inductive loads.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study is to evaluate lighting conditions and speleologists’ visual performance using optical filters when exposed to the lighting conditions of cave environments. A crosssectional study was conducted. Twenty-three speleologists were submitted to an evaluation of visual function in a clinical lab. An examination of visual acuity, contrast sensitivity, stereoacuity and flashlight illuminance levels was also performed in 16 of the 23 speleologists at two caves deprived of natural lightning. Two organic filters (450 nm and 550 nm) were used to compare visual function with and without filters. The mean age of the speleologists was 40.65 (± 10.93) years. We detected 26.1% participants with visual impairment of which refractive error (17.4%) was the major cause. In the cave environment the majority of the speleologists used a head flashlight with a mean illuminance of 451.0 ± 305.7 lux. Binocular visual acuity (BVA) was -0.05 ± 0.15 LogMAR (20/18). BVA for distance without filter was not statistically different from BVA with 550 nm or 450 nm filters (p = 0.093). Significant improved contrast sensitivity was observed with 450 nm filters for 6 cpd (p = 0.034) and 18 cpd (p = 0.026) spatial frequencies. There were no signs and symptoms of visual pathologies related to cave exposure. Illuminance levels were adequate to the majority of the activities performed. The enhancement in contrast sensitivity with filters could potentially improve tasks related with the activities performed in the cave.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trihalomethanes (THMs) are widely referred and studied as disinfection by-products (DBPs). The THMs that are most commonly detected are chloroform (TCM), bromodichloromethane (BDCM), chlorodibromomethane (CDBM), and bromoform (TBM). Several studies regarding the determination of THMs in swimming pool water and air samples have been published. This paper reviews the most recent work in this field, with a special focus on water and air sampling, sample preparation and analytical determination methods. An experimental study has been developed in order to optimize the headspace solid-phasemicroextraction (HS-SPME) conditions of TCM, BDCM, CDBM and TBM from water samples using a 23 factorial design. An extraction temperature of 45 °C, for 25min, and a desorption time of 5 min were found to be the best conditions. Analysis was performed by gas chromatography with an electron capture detector (GC-ECD). The method was successfully applied to a set of 27 swimming pool water samples collected in the Oporto area (Portugal). TCM was the only THM detected with levels between 4.5 and 406.5 μg L−1. Four of the samples exceeded the guideline value for total THMs in swimming pool water (100 μgL−1) indicated by the Portuguese Health Authority.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D. degree in Biochemistry at the Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Um dos princípios da Gestão é: “If you cannot measure it, you cannot improve it.” In The Economist – 26.Dez.2008, idea of 19th century English physicist Lord Kelvin. Embora seja uma afirmação aplicável à gestão económica, também pode ser utilizada no domínio da gestão da energia. Este trabalho surge da necessidade sentida pela empresa Continental - Industria Têxtil do Ave, S.A. em efetuar uma atualização dos seus standards de produção, minimizando os seus consumos de eletricidade e gás natural. Foi necessário efetuar o levantamento dos consumos em diversas máquinas e equipamentos industriais, caracterizando e analisando os consumos ao longo de todo o processo produtivo. Para o tratamento de dados recolhidos foi desenvolvida uma folha de cálculo em MS Office ExcelTM com metodologia adequada ao equipamento em análise, que dará apoio ao decisor para a identificação dos aspetos que melhorem o processo produtivo e garantam uma elevada eficiência energética. Porém, não se enquadra no âmbito do Plano Nacional de Racionalização de Energia, sendo uma “auditoria energética” ao processo produtivo. Recentemente, a empresa, tem vindo a utilizar equipamentos eletrónicos que permitem otimizar o funcionamento mecânico dos equipamentos e das potências instaladas dos transformadores, na tentativa de racionalizar o consumo da energia elétrica. Outros equipamentos como, conversores de frequência para controlo de motores, balastros eletrónicos que substituem os convencionais balastros ferromagnéticos das lâmpadas de descarga fluorescente, têm sido incluídos ao nível das instalações elétricas, sendo gradualmente substituída a eletromecânica pela eletrónica. Este tipo de soluções vem deteriorar as formas de onda da corrente e da tensão do sistema pela introdução de distorções harmónicas. Faz ainda parte deste trabalho, um estudo de uma solução que melhore, simultaneamente o fator de potência e reduza as harmónicas presentes num posto de transformação localizado no seio da fábrica. Esta solução, permite melhorar a qualidade da energia elétrica e as condições de continuidade de serviço, garantindo melhores condições de exploração e incrementando a produtividade da empresa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We compared, for Triatoma brasiliensis, the egg-laying process and the mortality of adults under conditions of almost permanent darkness and with normal laboratory luminosity. Mortality did not differ between groups. The egg-laying per vial and per female was significantly greater in the group of normal luminosity. We consider that it is not recommendable to keep the adults of this species under complete darkness. Other biological aspects should be analysed in relation to luminosity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

3rd Historic Mortars Conference, 11-14 September 2013, Glasgow, Scotland

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High reflective paints (cool paints) are used on flat roofs to reduce heat gains from the incidence of solar radiation and thus improve the thermal comfort and energy efficiency of buildings, especially in summer periods. Given the application potential of these paints on vertical surfaces, a research study has been developed to evaluate the thermal performance of reflective paints on walls under real exposure conditions. Accordingly, different reflective paints have been applied as the final coating of an ETICS type solution, on the facades of a full scale experimental cell built at LNEC campus. For being applied in an ETICS system a paint has to fulfill several requirements, whether aesthetic or functional (such as the adhesion between the coating layers or the durability of the insulation), essential for its efficient performance. Since this construction coating system is subject to a prolonged sun exposure, various problems may arise, such as paint degradation or deterioration of the thermal insulation properties, particularly when dark colors are applied. To evaluate the thermal performance of the chosen paints, the method of non-destructive analysis by Infrared Thermography was used. Thermography allows knowing the temperature distribution of facades by measuring the radiation emitted by their surfaces. To complement the thermographic diagnosis, thermocouples were placed between the insulation and the paint system of the experimental cell. Additional laboratory tests allowed the characterization of the optical properties (reflectance and emittance) of the different reflective paints used in this study. The comparative analysis of the thermal performance of reflective and conventional paints revealed that the reflective paint allows a reduction of the facade surface temperature, reducing the risk of loss of insulating properties of the ETICS system and thus ensuring its longevity and functionality. The color of the paint used affects, naturally, the reflective ability of the surface and may have an important role in energy balance of the building. This paper also showed the potential of infrared thermography in the evaluation of the thermal performance of reflective paints.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High molecular weight components from Ascaris suum extract suppress ovalbumin-specific immunity in mice. In IFN-γ-deficient mice, ovalbumin-specific delayed-type hypersensitivity reactions are more strongly downregulated by these suppressive components. Here, the cellularity of the delayed-type hypersensitivity reaction in IFN-γ-deficient mice and the increased downregulation induced by Ascaris suum components were analyzed. IL-12p40-dependent neutrophilic influx was predominant. Suboptimal doses of the suppressive fraction from this nematode completely inhibited the hypersensitivity reaction, thus indicating intensification of the immunosuppression under conditions of intense recruitment of IFN-γ-independent neutrophils.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Bacterial colonization of the lungs is the main cause of morbidity in cystic fibrosis (CF). Pathogens such as Staphylococcus aureus are very well adapted to the pulmonary environment and may persist for years in the same patient. Genetic determinants of these bacteria, such as the presence of SCCmec have recently emerged as a problem in this population of patients. METHODS: Staphylococcus aureus isolates obtained from different clinical materials coming from CF and non-CF patients attended at a cystic fibrosis reference hospital were compared according to SCCmec type and antibiotic susceptibility profile. RESULTS: Three hundred and sixty-four single-patient Staphylococcus aureus isolates were collected, of which 164 (45%) were from CF patients. Among the latter, 57/164 (44.5%) were MRSA, and among the non-CF patients, 89/200 (35%) were MRSA. Associated pathogens were found in 38 CF patients. All 57 MRSA from CF patients harbored the multiresistant cassette type III. In contrast, 31/89 MRSA from non-CF patients harbored SCCmec type I (35%) and 44/89 harbored type III (49%). The antibiotic susceptibility pattern was similar between CF and non-CF patients. CONCLUSIONS: The high prevalence of multiresistant SCCmec type III among CF patients compared with non-CF patients in our institution may make it difficult to control disease progression through antibiotic therapy for promoting the survival of this kind of patient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The aim of this study was to assess the epidemiological characteristics of Trypanosoma cruzi-infected mothers and the live birth conditions of neonates.METHODS:A serological survey with IgG-specific tests was conducted using dried blood samples from newborn infants in the State of Minas Gerais. T. cruzi infection was confirmed in mothers through positive serology in two different tests, and infected mothers were required to have their infants serologically tested after the age of 6 months. The birth conditions of the neonates were obtained from the System of Information on Live Births database.RESULTS:The study included 407 children born to T. cruzi-infected mothers and 407 children born to uninfected mothers. The average age of seropositive mothers was 32 years (CI95% 31.3-32.6), which was greater than the average age of seronegative mothers - 25 years (CI95% 24.8-25.2). The mothers' level of education was higher among uninfected mothers (41% had 8 or more years of education, versus 22% between the infected mothers). Vaginal delivery was more frequent among infected mothers. There was no evidence of inter-group differences with respect to the child's sex, gestational age, birth weight or Appearance, pulse, grimace, activity and respiration (APGAR) scores at 1 and 5 minutes.Conclusions:The level of education and the greater number of previous pregnancies and cases of vaginal delivery reflect the lower socioeconomical conditions of the infected mothers. In the absence of vertical transmission, neonates had similar health status irrespective of the infection status of their mothers.