950 resultados para Medical assessment
Resumo:
Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Objective. Endothelial impairment evaluation by sonographic measurement of flow-mediated dilatation (FMD) has become broadly used. However, this method has 2 main caveats: the dilatation depends on the baseline arterial diameter, and a high precision level is required. Vasodilatation leads to an amplified fall in impedance. We hypothesized that assessment of the pulsatility index change (PI-C) 1 minute after 5-minute forearm compression might evaluate that fall in impedance. The aim of this study was to compare the PI-C with FMD. Methods. Flow-mediated dilatation and the PI-C were assessed in 51 healthy women aged between 35.1 and 67.1 years. We correlated both FMD and the PI-C with age, body mass index, waist circumference, cholesterol level, high-density lipoprotein level, glucose level, systolic and diastolic blood pressure, pulse pressure, brachial artery diameter, simplified Framingham score, intima-media thickness, and carotid stiffness index. Intraclass correlation coefficients between 2 FMD and PI-C measurements were also examined. Results. Only FMD correlated with baseline brachial diameter (r=-0.53). The PI-C had a high correlation with age, body mass index, waist circumference, cholesterol level, systolic blood pressure, pulse pressure, simplified Framingham score, and intima-media thickness. The correlation between FMD and the PI-C was high (r=-0.66). The PI-C had a higher intraclass correlation coefficient (0.991) than FMD (0.836) but not brachial artery diameter (0.989). Conclusions. The PI-C had a large correlation with various markers of cardiovascular risk. Additionally, PI-C measurement does not require offline analysis, extra software, or electrocardiography We think that the PI-C could be considered a marker of endothelial function. However, more studies are required before further conclusions.
Resumo:
SETTING: Five medical schools in three cities in Rio de Janeiro State, Brazil, with different tuberculosis (TB) incidence rates. OBJECTIVE: To evaluate the prevalence of the booster phenomenon and its associated factors in a voting universally BCG-vaccinated TB-exposed population. DESIGN: A two-step tuberculin skin test (TST) was performed among undergraduate medical students. Boosting was defined as an induration >= 10 mm in the second TST (TST2), with an increase of at least 6 mm over the first TST (TST1). The association of boosting with independent variables was evaluated using multivariate analysis. RESULTS: Of the 764 participants (mean age 21.9 +/- 2.7 years), 672 (87.9%) had a BCG scar. The overall booster SUMMARY phenomenon prevalence was 8.4% (95%CI 6.5-10.6). Boosting was associated with TST1 reactions of 1-9 mm (aOR 2.5, 95%CI 1.04-5.9) and with BCG vaccination, mostly after infancy, i.e., after age two years (aOR 9.1, 95%,CI 1.2-70.7). CONCLUSION: The prevalence of the booster phenomenon was high. A two-step TST in young BCG-vaccinated populations, especially in those with TST1 reactions of 1-9 mm, can avoid misdiagnosis as a false conversion and potentially reduce unnecessary treatment for latent TB infection.
Resumo:
Objectives. To describe knowledge, practices, and associated factors of medical students to prevent transmission of tuberculosis (TB) in five medical schools. Methods. Cross-sectional survey of undergraduate medical students in preclinical and in early and late clinical years. Information was obtained on sociodemographic profile, previous lectures on TB, knowledge about TB transmission, exposure to patients with active pulmonary TB, and use of respiratory protective masks. Results. Among 1 094 respondents, 575 (52.6%) correctly answered that coughing, speaking, and sneezing can transmit TB. Early [adjusted odds ratio = 4.0 (3.0, 5.5)] and late [adjusted odds ratio = 4.2 (3.1, 5.8)] clinical years were associated with correct answers, but having had previous lectures on TB was not. Among those who had previous lectures on TB, the rate of correct answers increased from 42.1% to 61.6%. Among 332 medical students who reported exposure to TB patients, 194 (58.4%) had not used protective masks. More years of clinical experience was associated with the use of masks [adjusted odds ratio = 2.9 (1.4, 6.1)], while knowledge was inversely associated with the use of masks [adjusted odds ratio = 0.4 (0.2, 0.6)]. Conclusions. Many medical students are not aware of the main routes of TB infection, and lectures on TB are not sufficient to change knowledge and practices. Regardless of knowledge about TB transmission, students engage in risky behaviors: more than two-thirds do not use a protective mask when examining an active TB case. We suggest innovative, effective active learning experiences to change this scenario.
From medical librarian to informacionist: semantic traces of their profiles and areas of performance
Resumo:
This literature review retakes the discussion of the profiles and competences of the information area professional, specifically, in the health field. Therefore, the aim here is to outline the new fields of performance for the informationist and the profiles required in the health context.
Resumo:
The frontal assessment battery (FAB) is a bedside cognitive scale designed to measure executive functions. Huntington`s disease (HD) is a neurodegenerative disorder characterized by motor, behavioral, and cognitive dysfunction. The aim of this study was to check the validity of the FAB for the evaluation of cognitive impairment in patients with HD. Forty-one patients diagnosed with HD and 53 healthy controls matched by education, sex and age were evaluated with a validated Brazilian version of the UHDRS, the VFT, the SDMT, the SIT, the MMSE, and the FAB. The diagnosis of HD was made by DNA analysis. FAB scores were lower in patients than in the controls (p < 0.001) and had significant correlations with the VFT (r = 0.79; p < 0.05), the SDMT (r = 0.80; p < 0.05), the SIT (r = 0.72; p < 0.05), the MMSE (r = 0.83; p < 0.05), the FCS (r = 0.79; p < 0.05) and the motor section of the UHDRS (r = -0.80; p < 0.05). The FAB differentiated between HD patients in the initial and later stages of the disease. The one-year longitudinal evaluation revealed a global trend toward a worsening in the second score of the FAB. The results demonstrate that the FAB presents good internal consistency and also convergent and discriminative validity; therefore it is a useful scale to assess executive functions and to evaluate cognitive impairment in patients with HD.
Resumo:
Background. Play is an indication of a children`s development. Purpose. Organize a culturally adapt the Child-Initiated Pretend Play Assessment to Brazilian population. Method. Translation and cultural adaptation procedures consisted of translation, synthesis, back translation, author`s approval, and pretest of the assessment. For the pretest, 14 typically developing children were assessed. Was evaluated the use of play materials, duration of the assessment, and reliability. Findings. Play materials and duration of the assessment were appropriate for Brazilian children. Analysis of intra-rater reliability showed good agreement ranging from 0.90 to 1.00. Inter-rater reliability showed good to moderate agreement for five items ranging from 0.76 to 0.59. Four items showed chance to poor agreement (rho = -0.13 to 0.50). Implications. Results of the pretest indicate the Brazilian version of the ChIPPA is potentially useful for Brazilian children. ChIPPA training in Portuguese in Brazil with play observation feedback is recommended to improve inter-rater reliability.
Resumo:
Objectives: To assess the vestibular fold muscle after cordectomy and laryngeal reconstruction, the pattern of motor unit recruitment during sound emission, and the morphologic characteristics of motor unit action potentials. Design: Prospective analysis. Setting: Tertiary academic hospital. Patients: We evaluated 11 men (mean age, 65.7 years; age range, 53-82 years) who underwent laryngofissure, cordectomy, and laryngeal reconstruction with a vestibular fold flap. Interventions: Laryngeal electromyography with the insertion of a needle electrode for the assessment of the electrophysiologic activity of thyroartenoid muscle fibers and of the cricothyroid muscle on the operated on and nonoperated on sides. The thyroarytenoid muscle was evaluated by introducing a needle electrode through the thyroid cartilage and the cricothyroid membrane. Main Outcome Measures: Activities of needle insertion, spontaneous muscle activity during rest, and pattern of motor unit recruitment. Results: Seven patients (64%) had vestibular fold muscle fiber, all of whom showed motor unit recruitment in response to sound emission. No neurogenic muscle injuries were observed except in 1 patient with evidence of chronic injury. Conclusion: After cordectomy and laryngeal reconstruction, thyroarytenoid muscle fibers are present in the vestibular fold, with motor unit recruitment during sound emission.
Resumo:
The normalized electromyographic characteristics of masticatory muscles in patients with temporomandibular joint disorders (TMD) and healthy controls were compared. Thirty TMD patients (15 men, 15 women, mean age 23 years) with long lasting pain (more than 6 months), and 20 control subjects matched for sex and age were examined. All patients had arthrogenous TMD according to the Research Diagnostic Criteria for TMD (RDC/TMD). Surface electromyography of masseter and temporal muscles was performed during maximum teeth clenching either on cotton rolls or in intercuspal position. Standardized EMG indices and the median power frequency were obtained, and compared between the two groups and sexes using ANOVAs. During clenching, the TMD patients had larger asymmetry in their temporalis muscles, larger temporalis activity relative to masseter, and reduced mean power frequencies than the control subjects (p < 0.05, ANOVA). In both groups, the mean power frequencies of the temporalis muscles were larger than those of the masseter muscles (p < 0.001). No sex related differences, and no sex x group interactions were found. In conclusion, young adult patients with long lasting TMD have an increased and more asymmetric standardized activity of their temporalis anterior muscle, and reduced mean power frequencies, relative to healthy controls. (C) 2011 Elsevier Ltd. All rights reserved.