860 resultados para ADD-DROP FILTERS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dear Philip,

Thank you for adding your record to Pure. We notice that as of yet you have not uploaded your accepted manuscript for this publication.

As you may be aware HEFCE require that the accepted manuscripts of all journal articles and conference proceedings with an ISSN accepted from the 1st April 2016 are uploaded to Pure within 3 months of early online publication to ensure eligibility for the post 2014 REF.

The accepted manuscript is the final accepted version after changes from peer review have been incorporated. It is usually a Word or plain text file without publisher logos and prior to copy-editing and typesetting applied by the publisher.

If you have this version, I would be grateful if you could upload it to the record, selecting "Accepted author manuscript (post print)" from the document version drop down menu. If you have not done so already, please add your date of acceptance. Library staff will apply a copyright statement and any embargo required by the publisher.

Please contact me if you have any questions or require further information.

Kind regards,


Mark

Open Access Team

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resources created at the University of Southampton for the module Remote Sensing for Earth Observation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resources created at the University of Southampton for the module Remote Sensing for Earth Observation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Nuclear Medicine, radioiodine, in various chemical forms, is a key tracer used in diagnostic practices and/or therapy. Due to its high volatility, medical professionals may incorporate radioactive iodine during the preparation of the dose to be administered to the patient. In radioactive iodine therapy doses ranging from 3.7 to 7.4GBq per patient are employed. Thus, aiming at reducing the risk of occupational contamination, we developed a low cost filter to be installed at the exit of the exhaust system where doses of radioactive iodine are fractionated, using domestic technology. The effectiveness of radioactive iodine retention by silver impregnated silica [10%] crystals and natural activated carbon was verified using radiotracer techniques. The results showed that natural activated carbon is effective for I2 capture for a large or small amount of substrate but its use is restricted due to its low flash point (150º C). Besides, when poisoned by organic solvents, this flash point may become lower, causing explosions if absorbing large amounts of nitrates. To hold the CH3I gas, it was necessary to increase the volume of natural activated carbon since it was not absorbed by SiO2 + Ag crystals. We concluded that, for an exhaust flow range of (306 4) m3/h, a double stage filter using SiO2 + Ag in the first stage and natural activated carbon in the second is sufficient to meet radiological safety requirements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main aim of this work is to develop a methodology to evaluate the characteristics of porous media in filter using the radio-tracing technique. To do this, an experimental prototype filter made up of an acrylic cylinder, vertically mounted and supported on the lower side by a controlled leaking valve was developed. Two filters (spheres of acrylic and silica crystals) were used to check the movement of the water through the porous media using 123I in its MIBG (iodine-123-meta-iodo benzyl-guanidine) form. Further up the filter an instantaneous injection of the substance makes it possible to see the passage of radioactive clouds through the two scintillatory detectors NaI (2x2)” positioned before and immediately after the cylinder with the filtering element (porous media). The are caused by the detectors on the passage of the radioactive cloud are analyzed through statistical functions using the weighted moment method which makes it possible to calculate the Residence-Time (the amount of time the tracer takes to thoroughly pass through the filter) per the equation of dispersion in tubular flow and the one-directional flow of the radiotracer in the porous media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis focuses on the private membership test (PMT) problem and presents three single server protocols to resolve this problem. In the presented solutions, a client can perform an inclusion test for some record x in a server's database, without revealing his record. Moreover after executing the protocols, the contents of server's database remain secret. In each of these solutions, a different cryptographic protocol is utilized to construct a privacy preserving variant of Bloom filter. The three suggested solutions are slightly different from each other, from privacy perspective and also from complexity point of view. Therefore, their use cases are different and it is impossible to choose one that is clearly the best between all three. We present the software developments of the three protocols by utilizing various pseudocodes. The performance of our implementation is measured based on a real case scenario. This thesis is a spin-off from the Academy of Finland research project "Cloud Security Services".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation focuses on design challenges caused by secondary impacts to printed wiring assemblies (PWAs) within hand-held electronics due to accidental drop or impact loading. The continuing increase of functionality, miniaturization and affordability has resulted in a decrease in the size and weight of handheld electronic products. As a result, PWAs have become thinner and the clearances between surrounding structures have decreased. The resulting increase in flexibility of the PWAs in combination with the reduced clearances requires new design rules to minimize and survive possible internal collisions impacts between PWAs and surrounding structures. Such collisions are being termed ‘secondary impact’ in this study. The effect of secondary impact on board-level drop reliability of printed wiring boards (PWBs) assembled with MEMS microphone components, is investigated using a combination of testing, response and stress analysis, and damage modeling. The response analysis is conducted using a combination of numerical finite element modeling and simplified analytic models for additional parametric sensitivity studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In refrigeration systems a small amount of compressor lubricant is entrained in the refrigerant and circulated through the system, where some is retained in each component. The suction line to the compressor has the largest potential for oil retention. This paper presents results from an experimental apparatus that has been constructed to circulate POE (polyolester) oil and R410A at a controlled mass flux, OCR (oil in circulation ratio), and apparent superheat, and to directly measure the pressure drop and mass of oil retained in horizontal and vertical suction lines. The bulk vapor velocity and overall void fraction are determined from direct mass and temperature measurements. The oil retention, pressure drop, and flow regimes near the minimum ASHRAE recommended mass flux condition are explored. It was found that oil retention begins to increase sharply even above the minimum recommended flux, so conditions near the minimum should be avoided. Two relationships were developed to predict the oil retention in the vertical and horizontal suction lines. The average error from the predictions method was 10.9% for the vertical tube, and 7.9% for the horizontal tube.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This document describes the kinds of items accepted for recycling at Lexington County recycling centers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This sheet printed in English and Spanish gives tips on how to eat more vegetables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficient indirect office work brings competitive advantage for companies in a rapidly changing business environment. The direct work methods in factory floors have been developed already for decades, but the office work is an area where the potential to improve the value add has not been studied and utilized systematically so far. The first objective of the thesis work is to find useful method for identifying and managing value add using literature. The usefulness of the method is validated in the case company`s environment. The second objective of the work is to understand what kind of effort is required to create more efficient target setting for the white collar employees. The operative level targets should be linked more tightly to the company strategy. Lean methods are selected as a tool for the improvement, since they are widely used in all kinds of industries and they are already familiar in other functions in the case company. Based on the literature review, suitable improvement methods are selected. The core of the lean is to identify the value add of a customer and eliminate the waste. Also visual control, cross functional work team, flow office and continuous improvement are used. The methods are tested in one production line and the results and feedback indicate that methods are useful in the studied environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several Cronobacter outbreaks have implicated contaminated drinking water. This study assessed the impact of granular activated carbon (GAC) on the microbial quality of the water produced. A simulated water filter system was installed by filling plastic columns with sterile GAC, followed by sterile water with a dilute nutrient flowing through the column at a steady rate. Carbon columns were inoculated with Cronobacter on the surface, and the effluent monitored for Cronobacter levels. During a second phase, commercial faucet filters were distributed to households for 4-month use. Used filters were backwashed with sterile peptone water, and analyzed for Cronobacter, total aerobic plate count, coliform bacteria and Enterobacteriaceae. Cronobacter colonized the simulated GAC and grew when provided minimal levels of nutrients. Backwashed used filters used in home settings yielded presumptive Escherichia coli, Pseudomonas and other waterborne bacteria. Presumptive Cronobacter strains were identified as negative through biochemical and genetic test.