857 resultados para Waist-to-hip ratio


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Seismic sensors are widely used to detect moving target in ground sensor networks. Footstep detection is very important for security surveillance and other applications. Because of non-stationary characteristic of seismic signal and complex environment conditions, footstep detection is a very challenging problem. A novel wavelet denoising method based on singular value decomposition is used to solve these problems. The signal-to-noise ratio (SNR) of raw footstep signal is greatly improved using this strategy. The feature extraction method is also discussed after denosing procedure. Comparing, with kurtosis statistic feature, the wavelet energy feature is more promising for seismic footstep detection, especially in a long distance surveillance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we consider the continuous weak measurement of a solid-state qubit by single electron transistors (SET). For single-dot SET, we find that in nonlinear response regime the signal-to-noise ratio can violate the universal upper bound imposed quantum mechanically on any linear response detectors. We understand the violation by means of the cross-correlation of the detector currents. For double-dot SET, we discuss its robustness against wider range of temperatures, quantum efficiency, and the relevant open issues unresolved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For night remote surveillance, we present a method, the range-gated laser stroboscopic imaging(RGLSI), which uses a new kind of time delay integration mode to integrate target signals so that night remote surveillance can be realized by a low-energy illuminated laser. The time delay integration in this method has no influence on the video frame rate. Compared with the traditional range-gated laser imaging, RGLSI can reduce scintillation and target speckle effects and significantly improve the image signal-to-noise ratio analyzed. Even under low light level and low visibility conditions, the RGLSI system can effectively work. In a preliminary experiment, we have detected and recognized a railway bridge one kilometer away under a visibility of six kilometers, when the effective illuminated energy is 29.5 mu J.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

红外弱小目标检测技术是红外搜索与跟踪、红外预警、红外制导等防御和武器系统中的一项核心技术。研究复杂背景条件下的红外弱小目标检测技术,有利于提高红外探测系统的探测灵敏度,对增大系统作用距离、增加反应时间、提高己方的生存概率具有重要的意义。 本文针对复杂背景下的红外弱小目标检测技术进行了三个方面的研究: 1、 从红外成像系统方面对红外焦平面阵列的非均匀性校正问题进行研究。本文结合红外焦平面阵列的非线性模型(“S”形曲线模型)和Kalman滤波器,提出一种新的基于Kalman滤波的改进型两点校正法,该算法具有“S”形曲线两点校正法的处理简单、计算精度高等特点,同时利用Kalman滤波器对校正参数进行估计和修正,解决了“参数漂移”问题。实验仿真的结果表明,该算法能较好的对红外焦平面阵列进行非均匀校正。 2、 本文从红外图像预处理方面对红外背景抑制技术进行研究。针对传统的背景抑制算法难以解决的杂波干扰问题,本文提出了一种基于局部统计信息变化的自适应杂波抑制算法AFBLS(Adaptive Filter Based on Local Statistic),该算法能够对目标进行灰度增强,同时对杂波进行抑制。AFBLS算法结合传统的背景抑制算法,可以有效的对红外背景和杂波干扰进行抑制。对红外图像进行实验仿真的结论是:AFBLS杂波抑制算法是一种较好的红外弱小目标图像预处理方法,它能有效提高已有背景抑制算法的性能。 3、 本文对红外弱小目标检测算法进行了研究。分析了经典的管道算法的不足之处,并在此基础上对其进行改进,提出了动态更新的管道检测算法。通过仿真实验我们验证了改进的管道算法的性能,实验结果表明,该算法能够有效的对信噪比SNR(Signal-to-Noise Ratio)大于2的序列图像进行目标检测。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Optical films containing the genetic variant bacteriorhodopsin BR-D96N were experimentally studied in view of their properties as media for holographic storage. Different polarization recording schemes were tested and compared. The influence of the polarization states of the recording and readout waves on the retrieved diffractive image's intensity and its signal-to-noise ratio were analyzed. The experimental results showed that, compared with the other tested polarization relations during holographic recording, the discrimination between the polarization states of diffracted and scattered light is optimized with orthogonal circular polarization of the recording beams, and thus a high signal-to-noise ratio and a high diffraction efficiency are obtained. Using a He-Ne laser (633 nm, 3 mW) for recording and readout, a spatial light modulator as a data input element, and a 2D-CCD sensor for data capture in a Fourier-transform holographic setup, a storage density of 2 x 10(8) bits/cm(2) was obtained on a 60 x 42 mu m(2) area in the BR-D96N film. The readout of encoded binary data was possible with a zero-error rate at the tested storage density. (c) 2005 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recording with both parallel and orthogonal linearly polarized lights, polarization holographic storage in genetic mutant BR-D96N film is reported with both transmission type geometry and reflection type geometry. Polarization properties of diffraction light and scattering light are discussed for two different cases, parallel polarization recording and orthogonal polarization recording. It shows that, compared with recording with parallel polarization lights, orthogonal polarization holography can separate the diffraction light from the scattering noise, therefore improving the signal-to-noise ratio. It also shows that, compared with reconstruction with reference light, reconstruction with phase conjugated wave of the reference light can improve the signal-to-noise ratio of the reconstructed diffraction image, and also the wave-front aberration of the object light introduced by irregular phase object in the optical pass-way can also be corrected effectively, which ensures that the reconstructed diffraction image has a better fidelity. The preliminary angle-multiplexed volume holographic storage multiplexed by transmission type geometry and reflection type geometry is demonstrated in the BR-D96N film. Experiment shows that there is no cross-talk between the two pages of images except for some scattering noises.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

基于地统计学原理和半变异理论,采用地理信息系统技术定量研究了陕西省水蚀土壤因子指标的空间变异特征。分析比较了反距离权重法、样条函数法与普通克吕格法对陕西省土壤因子指标空间插值的精度。结果表明,研究区土壤抗冲系数具有中等强度的空间相关性,块金系数为32.29%,而稳渗速率、崩解速率、抗剪强度均表现为强烈的空间相关性,块金系数分别为13.19%,11.61%和12.98%。综合考虑平均相对误差、均方差及插值效果,认为普通克吕格法最好,更能反映土壤参数的空间特征并符合区域水土流失模型对数据的要求。对于普通克吕格法,稳渗速率的Lag步长为30 000 m,半方差理论模型为指数模型;抗冲系数、崩解速率、抗剪强度的Lag步长为55 000,半方差理论模型均为高斯模型。在空间分布上,各指标随土壤类型由北到南呈现明显的地带性规律。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Taking the inhomogenous broadening of the electron energy levels into account, a coherent model of the resonant tunneling (RT) of electrons in double quantum wells is presented. The validity of the model is confirmed with the experiments [M. Nido et al., Proc. SPIE 1268, 177 (1990)], and shows that the tunneling process can be explained by the simple coherent theory even in the presence of the carrier scattering. We have discussed the dependence of resonant tunneling on the barrier thickness L(B) by introducing the contrast ratio LAMBDA and the full width at half depth of the RT valley, and found that LAMBDA first increases with increasing barrier thickness, reaches a maximum, and then decreases with a further increase of L(B), in striking contrast to the Fabry-Perot model where a monotonic increase of the peak-to-valley ratio is predicted. We attribute the reduction of LAMBDA with large L(B) to the energy broadening resulting from the carrier scattering. A monotonic decrease of the full width at half depth of the RT valley with an increase of L(R) is also found.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new method using an atomic-resonance filter and deconvolution techniques has been developed to acquire high-resolution spectra of atmospheric Rayleigh-Mie scattering. In the deconvolution process, the difficulty of the undetermined division 0/0 is overcome by a fitting method. Preliminary laboratory experimental results on 90-deg scattering show that with a signal-to-noise ratio of 20, the scattered Rayleigh-Mie spectrum may be retrieved in agreement with the theoretical analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A fully-differential switched-capacitor sample-and-hold (S/H) circuit used in a 10-bit 50-MS/s pipeline analog-to-digital converter (ADC) was designed and fabricated using a 0.35-μm CMOS process. Capacitor fliparound architecture was used in the S/H circuit to lower the power consumption. In addition, a gain-boosted operational transconductance amplifier (OTA) was designed with a DC gain of 94 dB and a unit gain bandwidth of 460 MHz at a phase margin of 63 degree, which matches the S/H circuit. A novel double-side bootstrapped switch was used, improving the precision of the whole circuit. The measured results have shown that the S/H circuit reaches a spurious free dynamic range (SFDR) of 67 dB and a signal-to-noise ratio (SNR) of 62.1 dB for a 2.5 MHz input signal with 50 MS/s sampling rate. The 0.12 mm~2 S/H circuit operates from a 3.3 V supply and consumes 13.6 mW.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A technology for the monolithic integration of resonant tunneling diodes (RTDs) and high electron mobility transistors (HEMTs) is developed. Molecular beam epitaxy is used to grow an RTD on a HEMT structure on GaAs substrate. The RTD has a room temperature peak-to-valley ratio of 5.2:1 with a peak current density of 22.5kA/cm~2. The HEMT has a 1μm gate length with a-1V threshold voltage. A logic circuit called a monostableto-bistable transition logic element (MOBILE) circuit is developed. The experimental result confirms that the fabricated logic circuit operates successfully with frequency operations of up to 2GHz.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For an olfactory sensor or electronic nose the task is not only to detect the object concentration, but also to recognize it. It is well known that all the elements can be identified by their charge to mass ratio e+/m. We tried to use this principle for molecular recognition. Two kinds of sensors are used simultaneously in testing. One is Quartz Crystal Microbalance (QCM) for detecting the change in mass, the other is Interdigital Electrode (IE) for detecting the change in conduction. In this paper the principle and the feasibility of this method are reported. The preliminary results on the recognition of alcohols are presented. The multisensor can be used as an instrument for research on material properties and kinetic process as well.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For an olfactory sensor or electronic nose, the task is not only to detect the object concentration, but also to recognize it. It is well known that all the elements can be identified by their charge to mass ratio e(+)/m. We tried to imitate this principle for molecular recognition. Two kinds of sensors are used simultaneously in testing. One is quartz crystal microbalance (QCM) for detecting the change in mass, the other is interdigital electrode (IE) for detecting the change in conduction, as an electro-mass multi-sensor (EMMS). in this paper, the principle and the feasibility of this method are discussed. The preliminary results on the recognition of alcohol by EMMS coated with lipids are presented. Meanwhile, the multi-sensor can also be used as an instrument for research on some physico-chemistry problems. The change in conduction of coated membrane caused by one absorbed molecule is reported. It is found that when a QCM is coated with membrane, it still obeys the relationship Delta F (frequency change of QCM) = K Delta m (mass change of absorbed substance) and the proportional coefficient, K, depends not only on quartz properties but also on membrane characteristics as well. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

N-shaped negative differential resistance (NDR) with a high peak-to-valley ratio (PVR) is observed in a GaAs-based modulation-doped field effect transistor (MODFET) with InAs quantum dots (QDs) in the barrier layer (QDFET) compared with a GaAs MODFET. The NDR is explained as the real-space transfer (RST) of high-mobility electrons in a channel into nearby barrier layers with low mobility, and the PVR is enhanced dramatically upon inserting the QD layer. It is also revealed that the QD layer traps holes and acts as a positively charged nano-floating gate after a brief optical illumination, while it acts as a negatively charged nano-floating gate and depletes the adjacent channel when charged by the electrons. The NDR suggests a promising application in memory or high-speed logic devices for the QDFET structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

All-optical clock recovery for the return-to-zero modulation format is demonstrated experimentally at 40 Gbits/s by using an amplified feedback laser. A 40 GHz optical clock with a root-mean-square (rms) timing jitter of 130 fs and a carrier-to-noise ratio of 42 dB is obtained. Also, a 40 GHz optical clock with timing jitter of 137 fs is directly recovered from pseudo-non-return-to-zero signals degraded by polarization-mode dispersion (PMD). No preprocessing stage to enhance the clock tone is used. The rms timing jitter of the recovered clock is investigated for different values of input power and for varying amounts of waveform distortion due to PMD.