992 resultados para Total load


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Barmumycin was isolated from an extract of the marine actinomycete Streptomyces sp. BOSC-022A and found to be cytotoxic against various human tumor cell lines. Based on preliminary one- and two-dimensional 1H- and 13C-NMR spectra, the natural compound was initially assigned the structure of macrolactone-type compound 1, which was later prepared by two different routes. However, major spectroscopic differences between isolated barmumycin and 1 led to revision of the proposed structure as E-16. Based on synthesis of this new compound, and subsequent spectroscopic comparison of it to an authentic sample of barmumycin, the structure of the natural compound was indeed confirmed as that of E-16.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complications related to the neck-stem junction of modular stems used for total hip arthroplasty (THA) are generating increasing concern. A 74-year-old male had increasing pain and a cutaneous reaction around the scar 1 year after THA with a modular neck-stem. Imaging revealed osteolysis of the calcar and a pseudo-tumour adjacent to the neck-stem junction. Serum cobalt levels were elevated. Revision surgery to exchange the stem and liner and to resect the pseudo-tumour was performed. Analysis of the stem by scanning electron microscopy and by energy dispersive X-ray and white light interferometry showed fretting corrosion at the neck-stem junction contrasting with minimal changes at the head-neck junction. Thus, despite dry assembly of the neck and stem on the back table at primary THA, full neck-stem contact was not achieved, and the resulting micromotion at the interface led to fretting corrosion. This case highlights the mechanism of fretting corrosion at the neck-stem interface responsible for adverse local tissue reactions. Clinical and radiological follow-up is mandatory in patients with dual-modular stems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasing evidence suggests that working memory and perceptual processes are dynamically interrelated due to modulating activity in overlapping brain networks. However, the direct influence of working memory on the spatio-temporal brain dynamics of behaviorally relevant intervening information remains unclear. To investigate this issue, subjects performed a visual proximity grid perception task under three different visual-spatial working memory (VSWM) load conditions. VSWM load was manipulated by asking subjects to memorize the spatial locations of 6 or 3 disks. The grid was always presented between the encoding and recognition of the disk pattern. As a baseline condition, grid stimuli were presented without a VSWM context. VSWM load altered both perceptual performance and neural networks active during intervening grid encoding. Participants performed faster and more accurately on a challenging perceptual task under high VSWM load as compared to the low load and the baseline condition. Visual evoked potential (VEP) analyses identified changes in the configuration of the underlying sources in one particular period occurring 160-190 ms post-stimulus onset. Source analyses further showed an occipito-parietal down-regulation concurrent to the increased involvement of temporal and frontal resources in the high VSWM context. Together, these data suggest that cognitive control mechanisms supporting working memory may selectively enhance concurrent visual processing related to an independent goal. More broadly, our findings are in line with theoretical models implicating the engagement of frontal regions in synchronizing and optimizing mnemonic and perceptual resources towards multiple goals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims determinate the evaluation of the quality of 'Nanicão' banana, submitted to two conditions of storage temperature and three different kinds of package, using the technique of the Analysis of Principal Components (ACP), as a basis for an Analysis of Variance. The fruits used were 'Nanicão' bananas, at ripening degree 3, that is, more green than yellow. The packages tested were: "Torito" wood boxes, load capacity: 18 kg; "½ box" wood boxes, load capacity: 13 kg; and cardboard boxes, load capacity: 18 kg. The temperatures assessed were: room temperature (control); and (13±1ºC), with humidity controlled to 90±2,5%. Fruits were discarded when a sensory analysis determined they had become unfit for consumption. Peel coloration, percentages of imperfection, fresh mass, total acidity, pH, total soluble solids and percentages of sucrose were assessed. A completely randomized design with a 2-factorial treatment structure (packing X temperature) was used. The obtained data were analyzed through a multivariate analysis known as Principal Components Analysis, using S-plus 4.2. The conclusion was that the best packages to preserve the fruit were the ½ box ones, which proves that it is necessary to reduce the number of fruits per package to allow better ventilation and decreases mechanical injuries and ensure quality for more time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä tutkimuksessa esitellään MIG-juoton periaatteet ja tarkastellaan menetelmää siitä näkökulmasta, että menetelmä voisi toimia yhtenä varteenotettavana hitsattujen liitosten väsymiskestävyyden parantamismenetelmänä. Muiden parantamismenetelmien laajaa kirjoa esitellään lyhyesti. MIG-juoton soveltuvuutta parantamismenetelmäksi tutkittiin väsytyskokein. Kokeiden avulla määritettiin pelkästään MIG-juotetun liitoksen väsymiskestävyys erilaisissa tapauksissa. Lisäksi määritettiin väsymiskestävyys tapauksessa, jossa perinteisen MAG-pienahitsin rajaviivalle MIG-juotetiin ylimääräinen palko. Jälkimmäisessä tapauksessa menetelmä toimii väsymiskestävyyden parantamismenetelmänä. Väsytyskokeita tehtiin kaikkiaan 63 kpl.Kaikkiaan erilaisia väsytyskoesarjoja oli kymmenen, joista kuusi oli 8-10 koekappaletta käsittäviä varsinaisia tutkittavia tapauksia ja neljä pieniä, vain kaksi tai kolme koesauvaa käsittäviä pilottikoesarjoja. Koetuloksia verrattiin IIW:n(International Institute of Welding) suunnitteluohjeisiin ja suosituksiin. MIG-juotettujen liitosten väsymiskestävyys oli yleisesti ottaen hyvä. Päittäisliitosoli vähintään yhtä hyvä kuin tavanomaisesti hitsattu. Voimaa kantavassa taivutustapauksessa saatiin 110 % parempi väsymislujuus verrattuna IIW:n suunnitteluohjeeseen. Voimaa kantamattomissa poikittaisissa kiinnitysliitoksissa puolestaan saavutettiin paikallisia nimellisiä jännityksiä käyttäen 70-80 %:n parannus suunnitteluohjeeseen nähden. Pelkästään MIG-juotetun liitoksen ja 'parannetun' liitoksen väsymislujuudet olivat tässä tapauksessa likimain yhtä suuret. MIG-juottoa käytetään vaihtoehtoisena liittämismenetelmänä jo joissakin teollisissa sovelluksissa. Tämän tutkimuksen koetulokset antavat selviä viitteitä siitä, että menetelmä voisi toimia yhtenä varteenotettavana väsymiskestävyyden parantamiskeinona uusille tai korjatuille rakenteille. Vaaditaan kuitenkin vielä lisätutkimuksia, jotta menetelmää voisi soveltaa luottavaisin mielin tuotantokäytössä väsymiskestävyyden parantamismenetelmänä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is commonly observed that complex fabricated structures subject tofatigue loading fail at the welded joints. Some problems can be corrected by proper detail design but fatigue performance can also be improved using post-weld improvement methods. In general, improvement methods can be divided into two main groups: weld geometry modification methods and residual stress modification methods. The former remove weld toe defects and/or reduce the stress concentrationwhile the latter introduce compressive stress fields in the area where fatigue cracks are likely to initiate. Ultrasonic impact treatment (UIT) is a novel post-weld treatment method that influences both the residual stress distribution andimproves the local geometry of the weld. The structural fatigue strength of non-load carrying attachments in the as-welded condition has been experimentally compared to the structural fatigue strength of ultrasonic impact treated welds. Longitudinal attachment specimens made of two thicknesses of steel S355 J0 have been tested for determining the efficiency of ultrasonic impacttreatment. Treated welds were found to have about 50% greater structural fatigue strength, when the slope of the S-N-curve is three. High mean stress fatigue testing based on the Ohta-method decreased the degree of weld improvement only 19%. This indicated that the method could be also applied for large fabricated structures operating under high reactive residual stresses equilibrated within the volume of the structure. The thickness of specimens has no significant effect tothe structural fatigue strength. The fatigue class difference between 5 mm and 8 mm specimen was only 8%. It was hypothesized that the UIT method added a significant crack initiation period to the total fatigue life of the welded joints. Crack initiation life was estimated by a local strain approach. Material parameters were defined using a modified Uniform Material Law developed in Germany. Finite element analysis and X-ray diffraction were used to define, respectively, the stress concentration and mean stress. The theoretical fatigue life was found to have good accuracy comparing to experimental fatigue tests.The predictive behaviour of the local strain approach combined with the uniformmaterial law was excellent for the joint types and conditions studied in this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study was done with two different servo-systems. In the first system, a servo-hydraulic system was identified and then controlled by a fuzzy gainscheduling controller. The second servo-system, an electro-magnetic linear motor in suppressing the mechanical vibration and position tracking of a reference model are studied by using a neural network and an adaptive backstepping controller respectively. Followings are some descriptions of research methods. Electro Hydraulic Servo Systems (EHSS) are commonly used in industry. These kinds of systems are nonlinearin nature and their dynamic equations have several unknown parameters.System identification is a prerequisite to analysis of a dynamic system. One of the most promising novel evolutionary algorithms is the Differential Evolution (DE) for solving global optimization problems. In the study, the DE algorithm is proposed for handling nonlinear constraint functionswith boundary limits of variables to find the best parameters of a servo-hydraulic system with flexible load. The DE guarantees fast speed convergence and accurate solutions regardless the initial conditions of parameters. The control of hydraulic servo-systems has been the focus ofintense research over the past decades. These kinds of systems are nonlinear in nature and generally difficult to control. Since changing system parameters using the same gains will cause overshoot or even loss of system stability. The highly non-linear behaviour of these devices makes them ideal subjects for applying different types of sophisticated controllers. The study is concerned with a second order model reference to positioning control of a flexible load servo-hydraulic system using fuzzy gainscheduling. In the present research, to compensate the lack of dampingin a hydraulic system, an acceleration feedback was used. To compare the results, a pcontroller with feed-forward acceleration and different gains in extension and retraction is used. The design procedure for the controller and experimental results are discussed. The results suggest that using the fuzzy gain-scheduling controller decrease the error of position reference tracking. The second part of research was done on a PermanentMagnet Linear Synchronous Motor (PMLSM). In this study, a recurrent neural network compensator for suppressing mechanical vibration in PMLSM with a flexible load is studied. The linear motor is controlled by a conventional PI velocity controller, and the vibration of the flexible mechanism is suppressed by using a hybrid recurrent neural network. The differential evolution strategy and Kalman filter method are used to avoid the local minimum problem, and estimate the states of system respectively. The proposed control method is firstly designed by using non-linear simulation model built in Matlab Simulink and then implemented in practical test rig. The proposed method works satisfactorily and suppresses the vibration successfully. In the last part of research, a nonlinear load control method is developed and implemented for a PMLSM with a flexible load. The purpose of the controller is to track a flexible load to the desired position reference as fast as possible and without awkward oscillation. The control method is based on an adaptive backstepping algorithm whose stability is ensured by the Lyapunov stability theorem. The states of the system needed in the controller are estimated by using the Kalman filter. The proposed controller is implemented and tested in a linear motor test drive and responses are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent laboratory studies have suggested that heart rate variability (HRV) may be an appropriate criterion for training load (TL) quantification. The aim of this study was to validate a novel HRV index that may be used to assess TL in field conditions. Eleven well-trained long-distance male runners performed four exercises of different duration and intensity. TL was evaluated using Foster and Banister methods. In addition, HRV measurements were performed 5 minutes before exercise and 5 and 30 minutes after exercise. We calculated HRV index (TLHRV) based on the ratio between HRV decrease during exercise and HRV increase during recovery. HRV decrease during exercise was strongly correlated with exercise intensity (R = -0.70; p < 0.01) but not with exercise duration or training volume. TLHRV index was correlated with Foster (R = 0.61; p = 0.01) and Banister (R = 0.57; p = 0.01) methods. This study confirms that HRV changes during exercise and recovery phase are affected by both intensity and physiological impact of the exercise. Since the TLHRV formula takes into account the disturbance and the return to homeostatic balance induced by exercise, this new method provides an objective and rational TL index. However, some simplification of the protocol measurement could be envisaged for field use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabajo examina la magnitud y la frecuencia del transporte de sedimento (material disuelto, sedimento en suspensión y carga de fondo) en la cuenca de la riera de Arbúcies (Cordilleras Costeras Catalanas), a partir de los caudales diarios del periodo 1967-1992 y de las muestras de agua y sedimento obtenidas durante los años 1991 y 1992. Los resultados indican que el transporte en disolución es más uniforme en el tiempo que el transporte de material sólido, tanto en suspensión como de fondo. Los cálculos muestran que la carga sólida total depende sobre todo de crecidas frecuentes y de magnitud moderada, correspondientes al nivel de cauce lleno (bankfull). Cabe señalar, en este sentido, que los caudales bankfull suceden el 2,2% del tiempo y transportan el 56% del sedimento en suspensión y el 31% de la carga de fondo total anual. El caudal efectivo para el transporte de sedimento en este río es, por tanto, un suceso relativamente frecuente y de idéntica magnitud al caudal geomorfológicamente dominante o bankfull.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of research was to analyse the potential of Normalized Difference Vegetation Index (NDVI) maps from satellite images, yield maps and grapevine fertility and load variables to delineate zones with different wine grape properties for selective harvesting. Two vineyard blocks located in NE Spain (Cabernet Sauvignon and Syrah) were analysed. The NDVI was computed from a Quickbird-2 multi-spectral image at veraison (July 2005). Yield data was acquired by means of a yield monitor during September 2005. Other variables, such as the number of buds, number of shoots, number of wine grape clusters and weight of 100 berries were sampled in a 10 rows × 5 vines pattern and used as input variables, in combination with the NDVI, to define the clusters as alternative to yield maps. Two days prior to the harvesting, grape samples were taken. The analysed variables were probable alcoholic degree, pH of the juice, total acidity, total phenolics, colour, anthocyanins and tannins. The input variables, alone or in combination, were clustered (2 and 3 Clusters) by using the ISODATA algorithm, and an analysis of variance and a multiple rang test were performed. The results show that the zones derived from the NDVI maps are more effective to differentiate grape maturity and quality variables than the zones derived from the yield maps. The inclusion of other grapevine fertility and load variables did not improve the results.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Rhinovirus is the most common cause of respiratory viral infections and leads to frequent respiratory symptoms in lung transplant recipients. However, it remains unknown whether the rhinovirus load correlates with the severity of symptoms. OBJECTIVES: This study aimed to better characterize the pathogenesis of rhinoviral infection and the way in which viral load correlates with symptoms. STUDY DESIGN: We assessed rhinovirus load in positive upper respiratory specimens of patients enrolled prospectively in a cohort of 116 lung transplant recipients. Rhinovirus load was quantified according to a validated in-house, real-time, reverse transcription polymerase chain reaction in pooled nasopharyngeal and pharyngeal swabs. Symptoms were recorded in a standardised case report form completed at each screening/routine follow-up visit, or during any emergency visit occurring during the 3-year study. RESULTS: Rhinovirus infections were very frequent, including in asymptomatic patients not seeking a specific medical consultation. Rhinovirus load ranged between 4.1 and 8.3 log copies/ml according to the type of visit and clinical presentation. Patients with highest symptom scores tended to have higher viral loads, particularly those presenting systemic symptoms. When considering symptoms individually, rhinovirus load was significantly higher in the presence of symptoms such as sore throat, fever, sputum production, cough, and fatigue. There was no association between tacrolimus levels and rhinovirus load. CONCLUSIONS: Rhinovirus infections are very frequent in lung transplant recipients and rhinoviral load in the upper respiratory tract is relatively high even in asymptomatic patients. Patients with the highest symptom scores tend to have a higher rhinovirus load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi desenvolver um modelo para estimar a área foliar total de bananeira, cultivar Prata-Anã, utilizando dimensões lineares da terceira folha, como o comprimento, a largura e o número total de folhas na emissão da inflorescência. As regressões lineares foram determinadas considerando-se a área foliar total de cada planta (AFT) como variável dependente e o comprimento (C) e a largura (L) da terceira folha, o produto de CxL, o número total de folhas por planta (N) e o produto de CxLxN como variáveis independentes. O modelo linear que melhor estimou a área foliar total (AFTe) da bananeira 'Prata-Anã', ao nível de 5% de significância com R² de 0,89, foi a equação AFTe = 0,5187(CxLxN) + 9603,5.