983 resultados para Retenção de repatriado


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The modalities of treatment with prostheses over implants for total edentulous patients can be divided in fixed and removable prostheses (overdentures). The fixed prostheses modality has proven to offer better results as to the functional aspects and, results in higher longevity. Overdentures are considered as a modality of rehabilitation utilized to compensate the need for better retention, aside from augmenting chewing efficiency. Its use is justified by its facilitated hygiene, reduced surgical and prosthetic costs, reestablishment of labial support and elimination of the possibility of air escape. However, this option presents psychosocial downside, since the fact that it is considered a removable rehabilitation modality does not please the majority of patients. Although many patients prefer a fixed implant-supported prosthesis to a removable overdenture, frequently it is necessary to utilize an implant retained overdenture as an alternative to the treatment, due to anatomical, physiological, aesthetic, hygienic, and financial limitations regarding the patient. The objective of this study was to discuss a clinical case of a partially edentulous patient treated in the Implantodontic Surgery Post-Graduation Course from the Kenedy Dentistry Institute Mozarteum/Famosp Unit – Goiânia-Brazil), and submitted to osseointegrated implants surgical fixation techniques. A modality of differential diagnosis was established after osseointegration period, it aimed at facilitating the choice of a rehabilitation model that could favor the patient’s and professional`s expectations. Therefore the appreciated aspects were function, comfort, aesthetics, and especially the patient satisfaction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The association of mandibular distal extension removable partial dentures with an osteointegrated implant is a treatment option at hasn't been fully explored by modern rehabilitation dentistry yet. The objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. Eight models were created, representing, from a sagittal perspective: Model A (MA) – a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) – similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) – similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) – similar to ME, but ditfferent in the sense that there is an implant with an associated ERA retention system; Model G (MG) – similar to MA, however with a distally descending-ascending ridge format; Model H (MH) – similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip. The format of distal descending edge (ME and MF) was that presented worse results, so in the models with conventional RPD as in the models with RPD associated to the implant and ERA system of retention, for the structures gingival mucosa and tooth support. 1) the distally descending ridge presented the most significant stress in the model with the conventional RPD (ME) or with a prosthesis associated to an implant (MF) and 2) the horizontal ridge (MB) provided more relief to the support structures, such as the tooth and the spongy bone, when there was an implant associated to an ERA retention system. The incorporation of the implants with the ERA system retention, in the posterior area of the toothless edge, it promotes larger stability and retention to PPREL, improving the patient's masticatory acting and, consequently, its comfort and function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mucocele is a retention phenomenon from minor salivary gland caused by the excretory ducts rupture. This phenomenon may be caused by local trauma and its location is usually more frequent in the lower lip. Clinically, they appear as nodular lesions and may be exophytic and pedunculated. Histologically, this lesion can be classified as mucus extravasation phenomenon and mucus retention cyst. The treatments described in the literature are total lesion excision, marsupialization, cryosurgery, laser or micromarsupialização. To report a case of mucocele by mucus extravasation developed after a local trauma. A 7 years old Male was attended in the Pediatric Dentistry Clinic, Araçatuba School of Dentistry, complaining about the appearance of lesion in the lower lip since 40 days approximately. During clinical oral examination, it was observed that the lesion was pedunculated, nodular, fibrous to palpation, around 2 cm in diameter, similar in color to the surrounding mucosa, smoothly in surface, non-ulcerated and asymptomatic. As treatment, it was chosen the total lesion excision. Histopathology test confirmed the clinical diagnosis of: mucocele. Since mucocele is a frequent lesions in the oral cavity, it is extremely important that the professionals can to recognize this lesion (its pathogenesis and clinical features), to achieve a definitive diagnosis and perform an appropriate treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A reversed-phase high performance liquid chromatography method was validated for the determination of cefazolin sodium in lyophilized powder for solution for injection to be applied for quality control in pharmaceutical industry. The liquid chromatography method was conducted on a Zorbax Eclipse Plus C18 column (250 x 4.6 mm, 5 μm), maintained at room temperature. The mobile phase consisted of purified water: acetonitrile (60: 40 v/v), adjusted to pH 8 with triethylamine. The flow rate was of 0.5 mL min-1 and effluents were monitored at 270 nm. The retention time for cefazolin sodium was 3.6 min. The method proved to be linear (r2 =0.9999) over the concentration range of 30-80 µg mL-1. The selectivity of the method was proven through degradation studies. The method demonstrated satisfactory results for precision, accuracy, limits of detection and quantitation. The robustness of this method was evaluated using the Plackett–Burman fractional factorial experimental design with a matrix of 15 experiments and the statistical treatment proposed by Youden and Steiner. Finally, the proposed method could be also an advantageous option for the analysis of cefazolin sodium, contributing to improve the quality control and to assure the therapeutic efficacy

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)