860 resultados para Plastic Cracking
Resumo:
Dissertação para obtenção do Grau de Doutor em Química
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Dissertação apresentada à Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia, para obtenção do Grau de Mestre em Energia e Bioenergia
Resumo:
The paper presented herein proposes a reliability-based framework for quantifying the structural robustness considering the occurrence of a major earthquake (mainshock) and subsequent cascading hazard events, such as aftershocks that are triggered by the mainshock. These events can significantly increase the probability of failure of buildings, especially for structures that are damaged during the mainshock. The application of the proposed framework is exemplified through three numerical case studies. The case studies correspond to three SAC steel moment frame buildings of 3-, 9-, and 20- stories, which were designed to pre-Northridge codes and standards. Twodimensional nonlinear finite element models of the buildings are developed using the Open System for Earthquake Engineering Simulation framework (OpenSees), using a finite-length plastic hinge beam model and a bilinear constitutive law with deterioration, and are subjected to multiple mainshock-aftershock seismic sequences. For the three buildings analyzed herein, it is shown that the structural reliability under a single seismic event can be significantly different from that under a sequence of seismic events. The reliability-based robustness indicator used shows that the structural robustness is influenced by the extent by which a structure can distribute damage.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia e Gestão Industrial
Resumo:
Dissertação para obtenção do Grau de Doutor em Química Sustentável
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
Nowadays, existing 3D scanning cameras and microscopes in the market use digital or discrete sensors, such as CCDs or CMOS for object detection applications. However, these combined systems are not fast enough for some application scenarios since they require large data processing resources and can be cumbersome. Thereby, there is a clear interest in exploring the possibilities and performances of analogue sensors such as arrays of position sensitive detectors with the final goal of integrating them in 3D scanning cameras or microscopes for object detection purposes. The work performed in this thesis deals with the implementation of prototype systems in order to explore the application of object detection using amorphous silicon position sensors of 32 and 128 lines which were produced in the clean room at CENIMAT-CEMOP. During the first phase of this work, the fabrication and the study of the static and dynamic specifications of the sensors as well as their conditioning in relation to the existing scientific and technological knowledge became a starting point. Subsequently, relevant data acquisition and suitable signal processing electronics were assembled. Various prototypes were developed for the 32 and 128 array PSD sensors. Appropriate optical solutions were integrated to work together with the constructed prototypes, allowing the required experiments to be carried out and allowing the achievement of the results presented in this thesis. All control, data acquisition and 3D rendering platform software was implemented for the existing systems. All these components were combined together to form several integrated systems for the 32 and 128 line PSD 3D sensors. The performance of the 32 PSD array sensor and system was evaluated for machine vision applications such as for example 3D object rendering as well as for microscopy applications such as for example micro object movement detection. Trials were also performed involving the 128 array PSD sensor systems. Sensor channel non-linearities of approximately 4 to 7% were obtained. Overall results obtained show the possibility of using a linear array of 32/128 1D line sensors based on the amorphous silicon technology to render 3D profiles of objects. The system and setup presented allows 3D rendering at high speeds and at high frame rates. The minimum detail or gap that can be detected by the sensor system is approximately 350 μm when using this current setup. It is also possible to render an object in 3D within a scanning angle range of 15º to 85º and identify its real height as a function of the scanning angle and the image displacement distance on the sensor. Simple and not so simple objects, such as a rubber and a plastic fork, can be rendered in 3D properly and accurately also at high resolution, using this sensor and system platform. The nip structure sensor system can detect primary and even derived colors of objects by a proper adjustment of the integration time of the system and by combining white, red, green and blue (RGB) light sources. A mean colorimetric error of 25.7 was obtained. It is also possible to detect the movement of micrometer objects using the 32 PSD sensor system. This kind of setup offers the possibility to detect if a micro object is moving, what are its dimensions and what is its position in two dimensions, even at high speeds. Results show a non-linearity of about 3% and a spatial resolution of < 2µm.
Resumo:
As crescentes questões ambientais têm vindo a impor, entre outras, a necessidade da reciclagem dos desperdícios produzidos por diversos setores (agricultura, indústria e serviços). Nesta ótica têm vindo a surgir um conjunto alargado de produtos compósitos que incluem os compósitos de madeira-plástico (Wood Plastic Composites). Estes compósitos têm vindo a competir com os produtos de madeira em diversos nichos de mercado, sendo o maior deles os revestimentos de piso em ambiente exterior, vulgarmente designados de deckings. Estes compósitos são comercializados salientando as suas vantagens relativamente à madeira maciça, como seja maior durabilidade biológica e menor variabilidade de propriedades mecânicas e físicas. No final do ano 2013 e início de 2014, foram reportadas uma série de anomalias na aplicação de réguas de compósitos madeira-plástico, nomeadamente a diminuição do desempenho físico e mecânico destes materiais, quando sujeitos a períodos prolongados de humidificação. Embora, para a maioria dos casos reportados, estas anomalias se devam a condições deficientes de aplicação, a possibilidade de alteração de características à flexão, quando sujeitos a condições de uma aplicação exterior, ainda não se encontra bem estudada. Na presente dissertação são avaliados e apresentados os efeitos no comportamento à flexão de três tipos diferentes de réguas de compósito madeira-plástico, quando sujeitos a condições de humidade permanente ou cíclica. Para este efeito, foram conduzidos um conjunto de ensaios, nomeadamente, de flexão para determinação da pré-carga, de resistência à humidade e de variação dimensional e de módulo de elasticidade devido à imersão em água e a ambiente húmido. Posteriormente, os resultados obtidos foram sujeitos a uma verificação aos Estados Limite de Serviço. Os resultados revelaram reduzidas variações dimensionais (inchamento) e perdas significativas de módulo de elasticidade, apenas devido à exposição a elevados níveis de humidade, mostrando-se o caso de exposição prolongada a água líquida o mais gravoso. Relativamente aos Estados Limite de Serviço, sobretudo a longo prazo, os resultados mostraram-se bastante gravosos, nomeadamente para o material de menor qualidade.
Resumo:
INTRODUCTION: Toxoplasmosis is usually a benign infection, except in the event of ocular, central nervous system (CNS), or congenital disease and particularly when the patient is immunocompromised. Treatment consists of drugs that frequently cause adverse effects; thus, newer, more effective drugs are needed. In this study, the possible activity of artesunate, a drug successfully being used for the treatment of malaria, on Toxoplasma gondii growth in cell culture is evaluated and compared with the action of drugs that are already being used against this parasite. METHODS: LLC-MK2 cells were cultivated in RPMI medium, kept in disposable plastic bottles, and incubated at 36ºC with 5% CO2. Tachyzoites of the RH strain were used. The following drugs were tested: artesunate, cotrimoxazole, pentamidine, pyrimethamine, quinine, and trimethoprim. The effects of these drugs on tachyzoites and LLC-MK2 cells were analyzed using nonlinear regression analysis with Prism 3.0 software. RESULTS: Artesunate showed a mean tachyzoite inhibitory concentration (IC50) of 0.075µM and an LLC MK2 toxicity of 2.003µM. Pyrimethamine was effective at an IC50 of 0.482µM and a toxicity of 11.178µM. Trimethoprim alone was effective against the in vitro parasite. Cotrimoxazole also was effective against the parasite but at higher concentrations than those observed for artesunate and pyrimethamine. Pentamidine and quinine had no inhibitory effect over tachyzoites. CONCLUSIONS: Artesunate is proven in vitro to be a useful alternative for the treatment of toxoplasmosis, implying a subsequent in vivo effect and suggesting the mechanism of this drug against the parasite.
Resumo:
IntroductionWe compared feces culturing in charcoal or vermiculite to obtain Strongyloides venezuelensis larvae.MethodsFeces (5g) from infected rats was mixed with vermiculite (10g) or coal (10g) in plastic cups and incubated at 28°C for 48h. Larvae were recovered using Baermann-Moraes method.ResultsSignificantly higher number of positive larval cultures were recovered from vermiculite than from charcoal (15/17 and 4/17, respectively; p < 0.001; 990.6 ± 307.5 and 215 ± 78.1 larvae, p = 0.027).ConclusionsVermiculite yields more larvae and provides cleaner pellets, improving larvae identification and facilitating their use for other purposes.
Resumo:
The main purpose of the present dissertation is the simulation of the response of fibre grout strengthened RC panels when subjected to blast effects using the Applied Element Method, in order to validate and verify its applicability. Therefore, four experimental models, three of which were strengthened with a cement-based grout, each reinforced by one type of steel reinforcement, were tested against blast effects. After the calibration of the experimental set-up, it was possible to obtain and compare the response to the blast effects of the model without strengthening (reference model), and a fibre grout strengthened RC panel (strengthened model). Afterwards, a numerical model of the reference model was created in the commercial software Extreme Loading for Structures, which is based on the Applied Element Method, and calibrated to the obtained experimental results, namely to the residual displacement obtained by the experimental monitoring system. With the calibration verified, it is possible to assume that the numerical model correctly predicts the response of fibre grout RC panels when subjected to blast effects. In order to verify this assumption, the strengthened model was modelled and subjected to the blast effects of the corresponding experimental set-up. The comparison between the residual and maximum displacements and the bottom surface’s cracking obtained in the experimental and the numerical tests yields a difference of 4 % for the maximum displacements of the reference model, and a difference of 4 and 10 % for the residual and maximum displacements of the strengthened model, respectively. Additionally, the cracking on the bottom surface of the models was similar in both methods. Therefore, one can conclude that the Applied ElementMethod can correctly predict and simulate the response of fibre grout strengthened RC panels when subjected to blast effects.
Resumo:
Abstract:INTRODUCTION:Despite the recommendations by interpretation of resistance ratios obtained in laboratory bioassays, little is known about the actual impact of these results in the effectiveness of vector control activities in the field. In this context, our objective was to determine the mean value of different resistance ratios obtained by laboratory bioassays performed as part of the chemical control strategies of Triatoma sordida in the field.METHODS:Field bioassays were developed in Monte Azul and Coração de Jesus (Southeast, Brazil). In each location, samples were formed with three domestic units treated with alpha-cypermethrin 20.0% (Alfatek (r) 200 SC). One day after spraying, 10 fifth-instar nymphs remained in contact with the surfaces treated (adobe with plaster, adobe without plaster, or wood) with insecticide in plastic cones for 72h. Three cones were exposed inside the intradomicile and the peridomicile. The insects in the control group were exposed to an insecticide-free piece of cardboard. Mortality was measured 72h after removal of the insects from the treated surfaces. The tests were realized in triplicate.RESULTS:Mortality was 100.0% in all locations, except for Monte Azul; Landinho (96.6%) and Coração de Jesus; Barriguda (96.6%).CONCLUSIONS:Although the resistant populations in laboratory tests proved to be susceptible in the field, this observation is not sufficient to suggest that the cut-off points used to justify the resistance ratio should be changed. In this sense, we recommend that laboratory and field bioassays are carried out with a greater number of Triatominae populations to allow more in-depth consideration of the subject.
Resumo:
Prostate cancer (PCa) is the most common form of cancer in men, in Europe (World Health Organization data). The most recent statistics, in Portuguese territory, confirm this scenario, which states that about 50% of Portuguese men may suffer from prostate cancer and 15% of these will die from this condition. Its early detection is therefore fundamental. This is currently being done by Prostate Specific Antigen (PSA) screening in urine but false positive and negative results are quite often obtained and many patients are sent to unnecessary biopsy procedures. This early detection protocol may be improved, by the development of point-of-care cancer detection devices, not only to PSA but also to other biomarkers recently identified. Thus, the present work aims to screen several biomarkers in cultured human prostate cell lines, serum and urine samples, developing low cost sensors based on new synthetic biomaterials. Biomarkers considered in this study are the following: prostate specific antigen (PSA), annexin A3 (ANXA3), microseminoprotein-beta (MSMB) and sarcosine (SAR). The biomarker recognition may occurs by means of molecularly imprinted polymers (MIP), which are a kind of plastic antibodies, and enzymatic approaches. The growth of a rigid polymer, chemically stable, using the biomarker as a template allows the synthesis of the plastic antibody. MIPs show high sensitivity/selectivity and present much longer stability and much lower price than natural antibodies. This nanostructured material was prepared on a carbon solid. The interaction between the biomarker and the sensing-material produces electrical signals generating quantitative or semi-quantitative data. These devices allow inexpensive and portable detection in point-of-care testing.