1000 resultados para Fluxo de material particulado em suspensão


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the development of an easy, fast and effective procedure for the verification of the ideal gas law in splitless injection systems in order to improve the response. Results of a group of pesticides were used to demonstrate the suitability of the approach. The procedure helps establish experimental parameters through theoretical aspects. The improved instrumental response allowed extraction with lower sample volumes, the minimization of time and costs and the simplification of sample preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow system based on the sandwich technique is proposed for the sequential determination of ascorbic acid, dipyrone, acetylcysteine, captopril and paracetamol. The procedure is based on the reduction of Cu(II) by the analytes followed by the spectrophotometric measurement of the complex of Cu(I) with 2,2'-biquinoline 4,4'-dicarboxylic acid. Linear responses were achieved in the µmol L-1 range, with coefficients of variation better than 1.7%. Sampling rate was estimated as 60 determinations per hour, consuming 230 µg of BQA and generating 2.5 mL of waste per determination. Results for commercial samples agreed with those obtained by procedures recommended by the American and European pharmacopeias at the 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the adsorption of 17β-estradiol (E2) and 17α-ethinylestradiol (EE2) from aqueous solution by decomposed peat. The peat presented a good adsorption process, close to 76.2% for E2 removal and approximately 55.0% for EE2. Moreover, the results indicated a probable multi-layered process. Adsorption isotherms were well fitted by Freundlich model. The data were evaluated considering the pseudo-first-order and pseudo-second-order approaches, being the second more significant mechanism in the rate-controlling step. Thermodynamic data revealed that hormones adsorption onto peat is spontaneous under the employed experimental conditions. The results confirmed the potential of this adsorbent to be employed for effluents treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potentialities and applications of the Multiple Pulse Amperometric detection (MPA) coupled with Flow Injection Analysis (FIA) are evaluated. Important aspects as cleaning and activation of electrode surface, indirect and simultaneous analysis of electroactive compounds and the use of the internal standard method for quantifications utilizing FIA-MPA are presented. The main parameters concerning the detection of electroactive analytes by multiple pulse amperometric detection in flowing solutions were also discussed. In addition, aspects such as flow rate, sample volume, application time of the potential pulses and instrumentation necessary for implementing of the method were also addressed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection spectrophotometric procedure for the determination of glyphosate in commercial formulations of herbicides is proposed. The determination is based on the reaction of glyphosate and p-dimethylaminocinnamaldehyde, in acid medium, yielding a colored compound (l máx = 495 nm). Under optimal conditions, Beer's law is obeyed in a concentration range 40-640 mg mL-1 with a correlation coefficient of 0.9996. The detection limit was 8.60 mg mL-1 for glyphosate. The method was successfully applied for the determination of glyphosate in commercial formulations of herbicides. Recovery of glyphosate from various commercial samples of herbicides range from 91.0 to 110%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the difficulties reported for the suspension polymerization is control the size and granulometry of beads. The purpose of this work was to evaluate the use of cellulose nanowhiskers and mesoporous silica as stabilizers to reduce the size and the particle distribution. To monitor polymerization process was used FTIR-ATR spectroscopy. The morphology was analyzed by scanning electron microscopy. The particle size distribution was characterised using a CILAS granulometer. Thermal stability was studied by thermogravimetric analysis. The results indicated that cellulose nanowhiskers may provide stabilization and increase the thermal stability of the beads in contrast to mesoporous silica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hydroalcoholic extracts prepared from standard leaves of Maytenus ilicifolia and commercial samples of espinheira-santa were evaluated qualitatively (fingerprinting) and quantitatively. In this paper, fingerprinting chromatogram coupled with Principal Component Analysis (PCA) is described for the metabolomic analysis of standard and commercial espinheira-santa samples. The epicatechin standard was used as an external standard for the development and validation of a quantitative method for the analysis in herbal medicines using a photo diode array detector. This method has been applied for quantification of epicatechin in commercialized herbal medicines sold as espinheira-santa in Brazil and in the standard sample of M. ilicifolia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reversed-phase HPLC method was developed and validated to separate and simultaneously quantify the association of betamethasone sodium phosphate (BP) and betamethasone dipropionate (BD) in injectable suspensions. Chromatographic conditions were ternary gradient elution at 1.6 mL/min on a C18 column with 254 nm. The linearity of the method was established in the range 120 to 280 mg/mL BD, and 48 to 112 mg/mL BP. The RSD of intermediate precision of the method was <1% and recoveries were 99-101% for both drugs. The method proved selective, linear, precise, accurate and robust for quantifying BP and BD in commercial injectable suspensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfasalazine is a prodrug used in the treatment of the Chron's disease and rheumatoid arthritis. Two analytical methods for analysis of sulfasalazine in oral suspension were validated using Spectrophotometric and HPLC. There is not any pharmacopoeic method to assay sulfasalazine in oral suspension. The methods are insurance and fast execution for the quality control. Both, suspension and tablets 500 mg (Azulfin®) had been analyzed by methods using UV/VIS and HPLC and the results were satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is part of a study that focused on analyzing the contributions of didactic activities related to scientific language rhetoric characteristics aimed at developing students' abilities to identify such characteristics in chemistry scientific texts and critical reading of those texts. In this study, we present the theoretical basis adopted to determine the scientific discourse characteristics and for the production of the didactic material used in those activities. Latour, Coracini and Campanario studies on persuasive rhetorical strategies present in scientific articles aided the production of such material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioethanol is a strategic biofuel in Brazil. Thus, a strong metrological basis for its measurements is required to ensure the quality and promote its exportation. Recently, Inmetro certified a reference material for water content in bioethanol. This paper presents the results of these studies. The characterization, homogeneity, short-term stability and long-term stability uncertainty contributions values were 0.00500, 0.0166, 0.0355 and 0.0391 mg g-1, respectively. The certificated value for water content of bioethanol fuel was (3.65 ± 0.11) mg g-1. This CRM is the first and up to now the unique in the world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple flow system with multiple pulse amperometric detection using a single working electrode is proposed for simultaneous determination of ascorbic (AA) and acetylsalicylic (AAS) acids in pharmaceutical formulations. The procedure is based on application of two potential pulses: 0.90 V/50 ms: oxidation and determination of AA without the interference of AAS; 1.35 V/50 ms: oxidation of both compounds and quantification of AAS by current subtraction using a correction factor. Sampling rate was estimated as 125 injections per hour and the limits of detection were 0.17 and 0.16 µmol L-1 for AA and AAS, respectively. Results for commercial samples agreed with those obtained using HPLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multi-commuted flow system was developed to determine propylthiouracil (PTU) based on the reaction of its thiol form with iminoquinone radical generated by the oxidation of N,N-dimethyl-p-phenylenediamine in an alkaline medium. PTU can be found in tautomeric forms and the tautomeric equilibrium was displaced to enhance the thiol form. However, the reaction product is unstable and its residence time in the flow path was carefully investigated. The proposed procedure showed good precision (< 1.5%) and a limit of detection (3s) of 0.11 mg L-1. High recoveries were obtained in the validation test. The procedure was employed for propylthiouracil determination in medications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use and characterization of the first Certified Reference Material (CRM) of Brazilian coal for analytical quality control are presented. All results were determined within the limits of repeatability and reproducibility allowed under the standards. Notable among the characterization parameters was the mineral matter content (45.39%) obtained by an alternative procedure showing a low relative error (-2.1%) compared to the standard technique (low ashing temperature). The possible expanded application of this CRM application in national laboratories, beyond the certificated and reference parameters, has advantages such as lower cost and easy availability, but round robin tests must be performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compulsory in Brazil, toy certification aims to prevent possible risks in toy use. The Brazilian National Institute of Metrology (INMETRO) establishes the maximum concentration of toxic elements (TE) that may be present in toys. This study evaluates the presence of TE in different crayons, gouache and modeling clays using X-ray fluorescence. This technique is fast, has low operating cost and minimum sample pretreatment, resulting in a clean procedure without reagent consumption and waste generation. Bromine (in gouache) and Barium (in crayons) were the only potentially TE identified in the samples studied.