895 resultados para 230107 Differential, Difference and Integral Equations


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The RPC developed a new phantom to ensure comparable and consistent radiation administration in spinal radiosurgery clinical trials. This study assessed the phantom’s dosimetric and anatomic utility. The ‘spine phantom’ is a water filled thorax with anatomy encountered in spinal radiosurgery: target volume, vertebral column, spinal canal, esophagus, heart, and lungs. The dose to the target volume was measured with axial and sagittal planes of radiochromic film and thermoluminescent dosimeters (TLD). The dose distributions were measured with the radiochromic film calibrated to the absolute dose measured by the TLD. Four irradiations were administered: a four angle box plan, a seven angle conformal plan, a seven angle IMRT plan, and a nine angle IMRT plan (denoted as IMRT plan #1 and plan #2, respectively). In each plan, at least 95% of the defined tumor volume received 8 Gy. For each irradiation the planned and administered dose distributions were registered via pinpricks, and compared using point dose measurements, dose profiles, isodose distributions, and gamma analyses. Based on previous experience at the RPC, a gamma analysis was considering passing if greater than 95% of pixels passed the criteria of 5% dose difference and 3 mm distance-to-agreement. Each irradiation showed acceptable agreement in the qualitative assessments and exceeded the 95% passing rate at the 5% / 3 mm criteria, except IMRT plan #1, which was determined to have been poorly localized during treatment administration. The measured and planned dose distributions demonstrated acceptable agreement at the 5% / 3 mm criteria, and the spine phantom was determined to be a useful tool for the remote assessment of an institution’s treatment planning and dose delivery regimen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Radiological Physics Center (RPC) provides heterogeneous phantoms that are used to evaluate radiation treatment procedures as part of a comprehensive quality assurance program for institutions participating in clinical trials. It was hypothesized that the existing RPC heterogeneous thorax phantom can be modified to assess lung tumor proton beam therapy procedures involving patient simulation, treatment planning, and treatment delivery, and could confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 5%. The Hounsfield Units (HU) for lung equivalent materials (balsa wood and cork) was measured using a CT scanner. The relative linear stopping power (RLSP) of these materials was measured. The linear energy transfer (LET) of Gafchromic EBT2 film was analyzed utilizing parallel and perpendicular orientations in a water tank and compared to ion chamber readings. Both parallel and perpendicular orientations displayed a quenching effect underperforming the ion chamber, with the parallel orientation showing an average 31 % difference and the perpendicular showing an average of 15% difference. Two treatment plans were created that delivered the prescribed dose to the target volume, while achieving low entrance doses. Both treatment plans were designed using smeared compensators and expanded apertures, as would be utilized for a patient in the clinic. Plan 1a contained two beams that were set to orthogonal angles and a zero degree couch kick. Plan 1b utilized two beams set to 10 and 80 degrees with a 15 degree couch kick. EBT2 film and TLD were inserted and the phantom was irradiated 3 times for each plan. Both plans passed the criteria for the TLD measurements where the TLD values were within 7% of the dose calculated by Eclipse. Utilizing the 5%/3mm criteria, the 3 trial average of overall pass rate was 71% for Plan 1a. The 3 trial average for the overall pass rate was 76% for Plan 1b. The trials were then analyzed using RPC conventional lung treatment guidelines set forth by the RTOG: 5%/5mm, and an overall pass rate of 85%. Utilizing these criteria, only Plan 1b passed for all 3 trials, with an average overall pass rate of 89%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence of many critical structures in this region requires accurate treatment delivery. The Radiological Physics Center (RPC) acts as both a remote and on-site quality assurance agency that credentials institutions participating in clinical trials. To date, about 30% of all IMRT participants have failed the RPC’s remote audit using the IMRT H&N phantom. The purpose of this project is to evaluate possible causes of H&N IMRT delivery errors observed by the RPC, specifically IMRT treatment plan complexity and the use of improper dosimetry data from machines that were thought to be matched but in reality were not. Eight H&N IMRT plans with a range of complexity defined by total MU (1460-3466), number of segments (54-225), and modulation complexity scores (MCS) (0.181-0.609) were created in Pinnacle v.8m. These plans were delivered to the RPC’s H&N phantom on a single Varian Clinac. One of the IMRT plans (1851 MU, 88 segments, and MCS=0.469) was equivalent to the median H&N plan from 130 previous RPC H&N phantom irradiations. This average IMRT plan was also delivered on four matched Varian Clinac machines and the dose distribution calculated using a different 6MV beam model. Radiochromic film and TLD within the phantom were used to analyze the dose profiles and absolute doses, respectively. The measured and calculated were compared to evaluate the dosimetric accuracy. All deliveries met the RPC acceptance criteria of ±7% absolute dose difference and 4 mm distance-to-agreement (DTA). Additionally, gamma index analysis was performed for all deliveries using a ±7%/4mm and ±5%/3mm criteria. Increasing the treatment plan complexity by varying the MU, number of segments, or varying the MCS resulted in no clear trend toward an increase in dosimetric error determined by the absolute dose difference, DTA, or gamma index. Varying the delivery machines as well as the beam model (use of a Clinac 6EX 6MV beam model vs. Clinac 21EX 6MV model), also did not show any clear trend towards an increased dosimetric error using the same criteria indicated above.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Despite immense efforts into development of new antidepressant drugs, the increases of serotoninergic and catechominergic neurotransmission have remained the two major pharmacodynamic principles of current drug treatments for depression. Consequently, psychopathological or biological markers that predict response to drugs that selectively increase serotonin and/or catecholamine neurotransmission hold the potential to optimize the prescriber’s selection among currently available treatment options. The aim of this study was to elucidate the differential symptomatology and neurophysiology in response to reductions in serotonergic versus catecholaminergic neurotransmission in subjects at high risk of depression recurrence. Methods: Using identical neuroimaging procedures with [18F] fluorodeoxyglucose positron emission tomography after tryptophan depletion (TD) and catecholamine depletion (CD), subjects with remitted depression were compared to healthy controls in a double-blind, randomized, crossover design. Results: While TD induced significantly more depressed mood, sadness and hopelessness than CD, CD induced more inactivity, concentration difficulties, lassitude and somatic anxiety than TD. CD specifically increased glucose metabolism in the bilateral ventral striatum and decreased glucose metabolism in the bilateral orbitofrontal cortex, whereas TD specifically increased metabolism in the right prefrontal cortex and the posterior cingulate cortex (PCC). While we found direct associations between changes in brain metabolism and induced depressive symptoms following CD, the relationship between neural activity and symptoms was less clear after TD. Conclusions: In conclusion, this study showed that serotonin and catecholamines play common and differential roles in the pathophysiology of depression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fillers are frequently used in beautifying procedures. Despite major advancements of the chemical and biological features of injected materials, filler-related adverse events may occur, and can substantially impact the clinical outcome. Filler granulomas become manifest as visible grains, nodules, or papules around the site of the primary injection. Early recognition and proper treatment of filler-related complications is important because effective treatment options are available. In this report, we provide a comprehensive overview of the differential diagnosis and diagnostics and develop an algorithm of successful therapy regimens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We establish the convergence of pseudospectra in Hausdorff distance for closed operators acting in different Hilbert spaces and converging in the generalised norm resolvent sense. As an assumption, we exclude the case that the limiting operator has constant resolvent norm on an open set. We extend the class of operators for which it is known that the latter cannot happen by showing that if the resolvent norm is constant on an open set, then this constant is the global minimum. We present a number of examples exhibiting various resolvent norm behaviours and illustrating the applicability of this characterisation compared to known results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Retrorectal tumors are uncommon and the etiology diverse. Literature to define the preoperative diagnosis and plan the intraoperative management are uncommon. PRESENTATION OF CASE We describe a case of a 44 year old patient with a laparoscopic approach for the removal of a retrorectal tumor and emphasize on the preoperative diagnostics and the intraoperative, minimal invasive approach. DISCUSSION Especially because these tumors are rare and often an incidental finding in gynecologic surgery, it is important to know the various differential diagnoses and its consequences with the laparoscopic approach. CONCLUSION We suggest the laparoscopic approach in cases of retroperitoneal cysts of unknown origin is ideal also because anatomic structures, mostly nerves, can be easily spared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the differential rates and branching ratios of the radiative decays τ→lννγ, with l = e or μ, and μ→eννγ in the Standard Model at next-to-leading order. Radiative corrections are computed taking into account the full depencence on the mass m l of the final charged leptons, which is necessary for the correct determination of the branching ratios. Only partial agreement is found with previous calculations performed in the m l → 0 limit. Our results agree with the measurements of the branching ratios B(μ→eννγ) and B(τ→μννγ) for a minimum photon energy of 10 MeV in the μ and τ rest frames, respectively. Babar’s recent precise measurement of the branching ratio B(τ→eννγ), for the same photon energy threshold, differs from our prediction by 3.5 standard deviations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite immense efforts into development of new antidepressant drugs, the increases of serotoninergic and catecholaminergic neurotransmission have remained the two major pharmacodynamic principles of current drug treatments for depression. Consequently, psychopathological or biological markers that predict response to drugs that selectively increase serotonin and/or catecholamine neurotransmission hold the potential to optimize the prescriber's selection among currently available treatment options. The aim of this study was to elucidate the differential symptomatology and neurophysiology in response to reductions in serotonergic versus catecholaminergic neurotransmission in subjects at high risk of depression recurrence. Using identical neuroimaging procedures with [(18)F] fluorodeoxyglucose positron emission tomography after tryptophan depletion (TD) and catecholamine depletion (CD), subjects with remitted depression were compared with healthy controls in a double-blind, randomized, crossover design. Although TD induced significantly more depressed mood, sadness and hopelessness than CD, CD induced more inactivity, concentration difficulties, lassitude and somatic anxiety than TD. CD specifically increased glucose metabolism in the bilateral ventral striatum and decreased glucose metabolism in the bilateral orbitofrontal cortex, whereas TD specifically increased metabolism in the right prefrontal cortex and the posterior cingulate cortex. Although we found direct associations between changes in brain metabolism and induced depressive symptoms following CD, the relationship between neural activity and symptoms was less clear after TD. In conclusion, this study showed that serotonin and catecholamines have common and differential roles in the pathophysiology of depression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodal imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is claimed often in the H. pylori literature that spontaneous clearance (infection loss without attempts to treat) is uncommon, though little evidence supports this claim. Emerging evidence suggests that spontaneous clearance may be frequent in young children; however, factors that determine persistence of untreated H. pylori infection in childhood are not well understood. The author hypothesized that antibiotics taken for common infections cause spontaneous clearance of H. pylori infection in children. The Pasitos Cohort Study (19982005) investigated predictors of acquisition and persistence of H. pylori infection in children from El Paso, Texas, and Juarez, Mexico, enrolled prenatally at maternal-child clinics. Children were screened for infection at target intervals of 6 months from 6-84 months of age by the 13C-urea breath test corrected for body-size-dependent variation in CO2 production. This dissertation aimed to estimate the risk of spontaneous clearance at the next test following an initial detected H. pylori infection (first detected clearance), estimate the effect of antibiotic exposure on the risk of first detected clearance (risk difference), and estimate the effect of antibiotic exposure on the rate of first detected infection (rate ratio). Data on infection status and medication history were available for 608 children followed for a mean of 3.5 years. Among 265 subjects with a first detected infection, 218 had a subsequent test, and among them, the risk of first detected clearance was 68% (95% CI: 61-74%). Children who took antibiotics during the interval between first detected infection and next test had an increased probability (risk difference of 10 percentage points) of a first detected clearance. However, there was also a similar effect of average antibiotic use >0 courses across all intervals preceding the next test. Average antibiotic exposure across all intervals preceding the first detected infection appeared to have a much stronger protective effect than interval/specific exposure when estimating incidence rate ratios (0.45 vs. 1.0). Incidental antibiotic exposure appears to influence the acquisition and duration of childhood H. pylori infection, however, given that many exposed children acquired the infection and many unexposed children cleared the infection, antibiotic exposure does not explain all infection events. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Validation of treatment plan quality and dose calculation accuracy is essential for new radiotherapy techniques, including volumetric modulated arc therapy (VMAT). VMAT delivers intensity modulated radiotherapy treatments while simultaneously rotating the gantry, adding an additional level of complexity to both the dose calculation and delivery of VMAT treatments compared to static gantry IMRT. The purpose of this project was to compare two VMAT systems, Elekta VMAT and Varian RapidArc, to the current standard of care, IMRT, in terms of both treatment plan quality and dosimetric delivery accuracy using the Radiological Physics Center (RPC) head and neck (H&N) phantom. Clinically relevant treatment plans were created for the phantom using typical prescription and dose constraints for Elekta VMAT (planned with Pinnacle3 Smart Arc) and RapidArc and IMRT (both planned with Eclipse). The treatment plans were evaluated to determine if they were clinically comparable using several dosimetric criteria, including ability to meet dose objectives, hot spots, conformity index, and homogeneity index. The planned treatments were delivered to the phantom and absolute doses and relative dose distributions were measured with thermoluminescent dosimeters (TLDs) and radiochromic film, respectively. The measured and calculated doses of each treatment were compared to determine if they were clinically acceptable based upon RPC criteria of ±7% dose difference and 4 mm distance-to-agreement. Gamma analysis was used to assess dosimetric accuracy, as well. All treatment plans were able to meet the dosimetric objectives set by the RPC and had similar hot spots in the normal tissue. The Elekta VMAT plan was more homogenous but less conformal than the RapidArc and IMRT plans. When comparing the measured and calculated doses, all plans met the RPC ±7%/4 mm criteria. The percent of points passing the gamma analysis for each treatment delivery was acceptable. Treatment plan quality of the Elekta VMAT, RapidArc and IMRT treatments were comparable for consistent dose prescriptions and constraints. Additionally, the dosimetric accuracy of the Elekta VMAT and RapidArc treatments was verified to be within acceptable tolerances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este articulo plantea la idea de que la Educación Especial se introduce en lo común articulando el Derecho a la Diferencia con la Diferencia de Derechos, abriendo así una vía alternativa entre la pura lógica de la diferencia y la pura lógica de lo idéntico, o sea, entre la oferta educativa diferenciada y la homogenización. Para ello parte de escenas escolares cotidianas respecto del tratamiento de la diferencia, analizando en cada caso la lógica y las operaciones que se ponen en juego para retornar a la escena escolar con una viñeta que nos llevará a concluir que “para poder ser iguales tenemos que poder hacer cosas diferentes". Cada una de las experiencias escolares que se presentan queda enmarcada en una ética que renuncia a las “tareas a realizar" (Agamben; 2006) y para la que lo propio de todo sujeto es ser su misma posibilidad.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From July 4 to 18,1995 surface chlorophyll a concentrations (C_cs) and integral primary production (C_ps) were studied in the northeastern part of the Norwegian Sea (73°42'N; 13°16'E), over a test area where an accident of the nuclear submarine Komsomolets had taken place. It was found that during this interval C_cs decreased by factor of about 3.3 (from 0.78 to 0.24 mg/m**3); average chlorophyll concentration within the photo-synthetic layer (C_cl) decreased by factor of about 3.5 (from 0.97 to 0.28 mg/m**3). The value of C_ps in the water column varied slightly (from 445 to 539 mg C/m**2 per day), since decrease in C_cl was compensated both by 1.5-fold growth of the photosynthetic layer thickness (from 40 to 60 m) and by 2.1-fold increase in its average assimilation number (from 0.58 to 1.20 mg C/mg chl a per hour). Monthly averages of C_ps were obtained from published data on seasonal C_cs changes and on the level of incident solar irradiation. They were found to be less than 100 mg C/m**2 per day in March and October and 100-500 mg C/m**2 per day in April-June. Annual primary production calculated from above values was equal to 105 g C/m**2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Differential dissolution affects the isotopic composition of different species of planktonic foraminifera in different ways. In the two species studied here in cores from Ontong Java Plateau, the less resistant species, Globigerinoides sacculifer, is more readily affected at a shallower depth than the more resistant species, Pulleniatina obliquiloculata (2.9 versus 3.4 km), but shows a smaller and less predictable response to partial dissolution (0.2 to 0.3 per mil versus 0.6 to 0.7 per mil). Comparison of isotopic values from the last glacial period with those from the late Holocene indicates that the apparent dissolution effect is considerably reduced during the last glacial, presumably due to reduced dissolution intensity during glacial time. A change in the level of the lysocline of about 400 m is suggested. In the published isotope records from Pacific cores V28-238 and V28-239, the dissolution-generated difference in delta18O (noted previously by Shackleton and Opdyke [1976]) is seen to describe a mid-Brunhes dissolution maximum, between 300 and 500 thousand years ago. This mid-Brunhes dissolution excursion is well known from the Pacific and the Indian Ocean.