963 resultados para Tricuspid Valve


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to source contamination and wearing of instrument components problems caused by the direct insertion probe technique, a new way of introduction of low volatile compounds into mass spectrometer was tested. This new scheme comprises the introduction of the low volatile compounds solutions via a six port valve connected to a particle beam interface. Solutions of isatin were injected into this system and the best results were obtained with CH2Cl2, CH3OH and CH3CN. The solution inlet system has shown to be advantageous over the conventional way of direct insertion probe introduction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and inexpensive device to automate a water distilling apparatus is shown. It is composed by a magnetic floater placed in the water reservoir and a level control unit, which acts over the heating element circuit. In order to provide water saving, an electromagnetic valve is inserted in the water supply inlet. Some suggestions for the adaptation to other types of equipment are also offered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An important component for the automation of flow injection analysis (FIA) systems is the sample injection valve. A simple and inexpensive commutator with 16 pinch valves (8 normally open and 8 closed) was developed and configured as a multichannel injection valve. It is activated by a single solenoid of 3 Kgf, powered by a pulsed driver circuit, controlled by a microcomputer or a switch. FIA with spectrophometric detection of potassium dichromate solution was used for the evaluation of the new injection valve and its comparison with other valves, for sample loops of 50, 100, 200, 300 and 500 muL. The repeatability was favorable (RSD 1.0% for 15 injections at each loop volume) compared to a manual injector, an electropneumatic injector and an injector configured with three mini solenoid valves (RSD 1.1, 1.3 and 1.0%, respectively, for15 injections at each loop volume).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aquarium air pumps are proposed and evaluated as pneumatic liquid propulsion devices for flow injection and continuos flow analysis (FIA and CFA) systems. This kind of pump is widely available at a very low cost and it can sustain a pressure around of 4 psi (0.28 bar) indefinitely. By applying this air pressure onto a solution contained in a reservoir flask, it is possible to reach flow rates of up to 12.5 mL min-1 for circuits comprising reactors, made from 0.8 i.d. tubing with a length of 100 cm. The precise adjustment of flow rate below the maximum one can be made with a simplified needle valve or inserting in series a short length of capillary tube. The absence of flow pulsation is a definite advantage in comparison with peristaltic pumps, especially when amperometric detection is elected, as confirmed experimentally in FIA and CF applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This technical note describes a new and simple electronic circuit for driving solenoid valves. The circuit is based on a single integrated circuit DRV103, which is able to drive resistive or inductive loads up to 1.5 A. Switching of 12-V loads can be controlled by TTLlevel signals in two distinct steps. Initially, 12 V is applied during 110 ms, followed by 4.2 V RMS until the end of the activation TTL pulse. This mode of operation is particularly suitable to drive solenoids, because it requires a higher voltage to start and a lower maintenance voltage. By using this circuit, power consumption and heating are reduced and the solenoid lifetime is enhanced. Moreover, this circuit is specially appropriated to build computercontrolled solenoid valves systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Power transformer is the most expensive equipment on a substation. It is always necessary to get needed benefit with the lowest expenses. Producing of power transformers with reduced insulation strength is one of the possible ways to reduce expenses. Exploitation of such transformers was begun in the end of 70-th in the last century. Protection from overvoltages was done with valve-type magnetic combined surge arresters with increased blanking voltage during switching overvoltages. Nowadays there is the necessity of replacement of those devices. That’s why modernized nonlinear surge arrester was invented. This master’s thesis is focused on the use research of that modernized device in comparison with usual nonlinear surge arresters. The goal is to show the lightning overvoltages level using different types of nonlinear surge arresters and then calculations of the lightning protection reliability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new configuration for coupling a gas diffusion cell to a sequential injection system is presented. The matrix exchange is made without the need for additional rotary injection valves or peristaltic pumps, keeping the original mechanical components of the sequential injection apparatus: one syringe pump (or peristaltic pump) and one selection valve. The system was tested constructing analytical curves for sulfide exploring the formation of the methylene blue dye. The proposed method has a detection limit of 60 µg L-1 S2-, with a linear dynamic range between 0.10 and 4.0 mg L-1 S2- concentrations, with a sampling frequency of 20 h-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Río Negro Formation (late Miocene-early Pliocene) mainly consists of continental deposits, but it contains a middle member of marine origin. It represents a transgressive-regressive sequence that can be seen at several outcrops along the N Patagonian coast. The taphonomical approach to the El Espigón marine deposits permits the identification of four main layers containing different kinds of skeletal accumulation, which mainly consist of oyster shells [Crassostrea patagonica (D'Orbigny, 1842)]. These concentrations display three different morphologies (pouches, pavements and bouquets) with a different taphonomic signature. These deposits were formed in shallow marine environments influenced by wave activity that produced valve concentrations of different entities. They contain several shell beds that represent event, composite, hiatal to lag skeletal concentrations. Traces of bioturbation in the sediment (Thalassinoides, Teichichnus) and bioerosion on the shells (Entobia, Gastrochaeonolites, Caulostrepsis), and encrusters (cirripeds, bryozoans), are also abundant in the outcrop and consititue common components of these Miocene materials. Layers 1 and 2 of the sequence were deposited in shoreface/foreshore environments at the beginning of a highstand systems tract, while layers 3 and 4 were deposited at the end, or at the beginning of a forced regression, in foreshore environments. A final erosional episode cut the top of the layer 4, which truncated the abundant bioturbaation developed there.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä diplomityössä käydään läpi IEC-60534 -standardin mukainen säätöventtiilin mitoitus kokoonpuristumattomille ja –puristuville virtauksille laskennassa tarvittavine yhtälöineen. Teoreettisessa osassa esitellään RF-letkuventtiilien rakennetta ja ominaisuuksia. Lisäksi käydään läpi putkivirtauksen perusperiaatteita. Koska letkuventtiilissä virtaavana fluidina on usein jokin liete, on työssä esitelty menetelmä lietevirtauksen aiheuttaman paine-eron laskentaan. Työssä on käsitelty myös kavitaation syntyä, laskennalliset mahdollisuudet kavitaation ennustamiseen sekä keinoja kavitaation estämiseksi. Kokeellisessa osassa suoritettiin mittauksia kolmella erikokoisella RF-letkuventtiilillä, joissa kussakin käytettiin kolmea erityyppistä letkua. Mittausten perusteella pystyttiin laskemaan kapasiteettikertoimet sekä määrittämään säätökäyrät mitatuille venttiileille ja letkutyypeille. Näistä tuloksista säätökäyrille sovitettiin yhtälöt, joiden perusteella saatiin laskettua kapasiteettikertoimien arvot myös muille venttiilikoille.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A prospective two dimensional and Doppler echocardiographic study of 70 consecutive patients with systemic lupus erythematosus (SLE) and 40 controls was carried out. Forty patients (57%) were found to have echocardiographic disturbance. Valvular abnormalities were detected in 31 patients (44%) and in only two controls (5%). Mitral valve abnormalities were the most common findings (23/70 (33%)) with mild or moderate regurgitation the most frequent lesion (16% and 9% respectively). Three patients (4%) had a morphological echocardiographic pattern suggestive of non-infective verrucous vegetations affecting the mitral valve. No patient had haemodynamically significant clinical valve disease. Pericardial effusion was identified in 19 patients (27%), of whom 14 had mild and clinically silent disease. Myocardial abnormalities were found in 14 patients (20%), but clinical features of myocardial dysfunction were present in only one. Patients with antiphospholipid antibodies were found to have an increased prevalence of endocardial lesions, mainly valvular regurgitation. It is concluded that the inclusion of echocardiography in a study protocol of patients with SLE can identify an important subset of patients with cardiac abnormalities, many of which are clinically silent. In addition, the association of antiphospholipid antibodies with endocardial lesions suggests that these antibodies may have a prominent role in the pathogenetic mechanisms of heart valve disease in SLE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A prospective two dimensional and Doppler echocardiographic study of 70 consecutive patients with systemic lupus erythematosus (SLE) and 40 controls was carried out. Forty patients (57%) were found to have echocardiographic disturbance. Valvular abnormalities were detected in 31 patients (44%) and in only two controls (5%). Mitral valve abnormalities were the most common findings (23/70 (33%)) with mild or moderate regurgitation the most frequent lesion (16% and 9% respectively). Three patients (4%) had a morphological echocardiographic pattern suggestive of non-infective verrucous vegetations affecting the mitral valve. No patient had haemodynamically significant clinical valve disease. Pericardial effusion was identified in 19 patients (27%), of whom 14 had mild and clinically silent disease. Myocardial abnormalities were found in 14 patients (20%), but clinical features of myocardial dysfunction were present in only one. Patients with antiphospholipid antibodies were found to have an increased prevalence of endocardial lesions, mainly valvular regurgitation. It is concluded that the inclusion of echocardiography in a study protocol of patients with SLE can identify an important subset of patients with cardiac abnormalities, many of which are clinically silent. In addition, the association of antiphospholipid antibodies with endocardial lesions suggests that these antibodies may have a prominent role in the pathogenetic mechanisms of heart valve disease in SLE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nauhakotelossa käsiohjelman ensimmäinen sivu. Ilmeisesti konsertissa esitetty muitakin teoksia kuin tällä nauhalla olevat, sillä konsertin solisteiksi lueteltu nauhalla esiintyvien lisäksi Marianne Segerstam (sopraano), Astrid Riska (altto) ja Pekka Salomaa (basso).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Soitinnus: lauluäänet (sopraano, tenori), poikakuoro, kamariorkesteri.