995 resultados para NETWORK-ANALYZER CALIBRATION
Resumo:
The mobile networks of earlier and current generations, or 2G and 3G networks, provide users voice and packet services with higher transmission rates and good quality over the same core network. When developing the next generation of mobile networks the current quality of services needs to be maintained. This thesis concentrates on the next generation mobile network, especially on the evolution of the packet network part. The new mobile network has requirements for the common packet backbone network, Mobile Packet Backbone Network, which is additionally discussed in this study. The next generation mobile network, called LTE/SAE, is currently under testing. The test system is called Container Trial System. It is a mini sized LTE/SAE site. The LTE/SAE is studied in this thesis concentrating on the evolved packet core, the SAE part of the composition. The empirical part of the study compares the LTE/SAE Container Trial System and commercial network designs and additionally produces documentation for internal personnel and customers. The research is performed by comparing the documentations and specifications of both the Container Trial System and commercial network. Since the LTE commercial network is not yet constructed, the comparison is done theoretically. The purpose is furthermore to find out if there are any design issues that could be done differently in the next version of the Container Trial System.
Resumo:
Aim of the Thesis is to study and understand the theoretical concept of Metanational corporation and understand how the Web 2.0 technologies can be used to support the theory. Empiric part of the study compares the theory to the case company’s current situation Goal of theoretical framework is to show how the Web 2.0 technologies can be used in the three levels of the Metanational corporation. In order to do this, knowledge management and more accurately knowledge transferring is studied to understand what is needed from the Web 2.0 technologies in the different functions and operations of the Metanational corporation. Final synthesis of the theoretical framework is to present a model where the Web 2.0 technologies are placed on the levels of the Metanational corporation. Empirical part of the study is based on interviews made in the case company. Aim of the interviews is to understand the current state of the company related to the theoretical framework. Based on the interviews, the differences between the theoretical concept and the case company are presented and studied. Finally the study presents the found problem areas, and where the adoption of the Web 2.0 tools is seen as beneficiary, based on the interviews and theoretical framework.
Resumo:
Traditionally, in the cigarettes industry, the determination of ammonium ion in the mainstream smoke is performed by ion chromatography. This work studies this determination and compares the results of this technique with the use of external and internal standard calibration. A reference cigarette sample presented measurement uncertainty of 2.0 μg/cigarette and 1.5 μg/cigarette, with external and internal standard, respectively. It is observed that the greatest source of uncertainty is the bias correction factor and that it is even more significant when using external standard, confirming thus the importance of internal standardization for this correction.
Resumo:
Multivariate models were developed using Artificial Neural Network (ANN) and Least Square - Support Vector Machines (LS-SVM) for estimating lignin siringyl/guaiacyl ratio and the contents of cellulose, hemicelluloses and lignin in eucalyptus wood by pyrolysis associated to gaseous chromatography and mass spectrometry (Py-GC/MS). The results obtained by two calibration methods were in agreement with those of reference methods. However a comparison indicated that the LS-SVM model presented better predictive capacity for the cellulose and lignin contents, while the ANN model presented was more adequate for estimating the hemicelluloses content and lignin siringyl/guaiacyl ratio.
Resumo:
The simultaneous determination of two or more active components in pharmaceutical preparations, without previous chemical separation, is a common analytical problem. Published works describe the determination of AZT and 3TC separately, as raw material or in different pharmaceutical preparations. In this work, a method using UV spectroscopy and multivariate calibration is described for the simultaneous measurement of 3TC and AZT in fixed dose combinations. The methodology was validated and applied to determine the AZT+3TC contents in tablets from five different manufacturers, as well as their dissolution profile. The results obtained employing the proposed methodology was similar to methods using first derivative technique and HPLC.
Resumo:
In this work, a spectrophotometric methodology was applied in order to determine epinephrine (EP), uric acid (UA), and acetaminophen (AC) in pharmaceutical formulations and spiked human serum, plasma, and urine by using a multivariate approach. Multivariate calibration methods such as partial least squares (PLS) methods and its derivates were used to obtain a model for simultaneous determination of EP, UA and AC with good figures of merit and mixture design was in the range of 1.8 - 35.3, 1.7 - 16.8, and 1.5 - 12.1 µg mL-1. The 2nd derivate PLS showed recoveries of 95.3 - 103.3, 93.3 - 104.0, and 94.0 - 105.5 µg mL-1 for EP, UA, and AC, respectively.
LOW COST ANALYZER FOR THE DETERMINATION OF PHOSPHORUS BASED ON OPEN-SOURCE HARDWARE AND PULSED FLOWS
Resumo:
The need for automated analyzers for industrial and environmental samples has triggered the research for new and cost-effective strategies of automation and control of analytical systems. The widespread availability of open-source hardware together with novel analytical methods based on pulsed flows have opened the possibility of implementing standalone automated analytical systems at low cost. Among the areas that can benefit from this approach are the analysis of industrial products and effluents and environmental analysis. In this work, a multi-pumping flow system is proposed for the determination of phosphorus in effluents and polluted water samples. The system employs photometric detection based on the formation of molybdovanadophosphoric acid, and the fluidic circuit is built using three solenoid micropumps. The detection is implemented with a low cost LED-photodiode photometric detection system and the whole system is controlled by an open-source Arduino Uno microcontroller board. The optimization of the timing to ensure the color development and the pumping cycle is discussed for the proposed implementation. Experimental results to evaluate the system behavior are presented verifying a linear relationship between the relative absorbance and the phosphorus concentrations for levels as high as 50 mg L-1.
Resumo:
@450 wireless broadband service is Digita’s mobile wireless broadband network service. In @450 network Digita acts as the network operator offering network capacity to service operators. For Digita it is important to know what kind of services its network is capable of and what are the network’s service parameters. The knowledge of the network parameters and the behaviour can be used in advance in the development of new service products. Before a new service product can be offered to service operators a lot of work has to be done. The basic testing is necessary to get an understanding of the basic functionality. The requirement specification has to be done and a new product has to be created. The new product has to be tested. The test results have to be analysed in order to find out if the new product is suitable for real use and with which limitations. The content of this Thesis is the development of wireless technologies, @450 service and network, FLASH-OFDM technology, FLASH-OFDM performance testing and the development of a new service product.
Resumo:
Deregulation of the electricity sector liberated the electricity sale and production for competitive forces while in the network business, electricity transmission and distribution, natural monopoly positions were recognised. Deregulation was accompanied by efficiencyoriented thinking on the whole electricity supply industry. For electricity distribution this meant a transition from a public service towards profit-driven business guided by economic regulation. Regulation is the primary means to enforce societal and other goals in the regulated monopoly sector. The design of economic regulation is concerned with two main attributes; end-customer price and quality of electricity distribution services. Regulation limits the costs of the regulated company but also defines the desired quality of monopoly services. The characteristics of the regulatory framework and the incentives it provides are therefore decisive for the electricity distribution sector. Regulation is not a static factor; changes in the regulatory practices cause discontinuity points, which in turn generate risks. A variety of social and environmental concerns together with technological advancements have emphasised the relevance of quality regulation, which is expected to lead to the large-scale replacement of overhead lines with underground cables. The electricity network construction activity is therefore currently witnessing revolutionary changes in its competitive landscape. In a business characterised by high statutory involvement and a high level of sunk costs, recognising and understanding the regulatory risks becomes a key success factor. As a response, electricity distribution companies have turned into outsourcing to attain efficiency and quality goals. This doctoral thesis addresses the impacts of regulatory risks on electricity network construction, which is a commonly outsourced activity in the electricity distribution network sector. The chosen research approach is characterised as an action analytical research on account of the fact that regulatory risks are greatly dependent on the individual nature of the regulatory regime applied in the electricity distribution sector. The main contribution of this doctoral thesis is to develop a concept for recognising and managing the business risks stemming from economic regulation. The degree of outsourcing in the sector is expected to increase in years to come. The results of the research provide new knowledge to manage the regulatory risks when outsourcing services.
Resumo:
Modern sophisticated telecommunication devices require even more and more comprehensive testing to ensure quality. The test case amount to ensure well enough coverage of testing has increased rapidly and this increased demand cannot be fulfilled anymore only by using manual testing. Also new agile development models require execution of all test cases with every iteration. This has lead manufactures to use test automation more than ever to achieve adequate testing coverage and quality. This thesis is separated into three parts. Evolution of cellular networks is presented at the beginning of the first part. Also software testing, test automation and the influence of development model for testing are examined in the first part. The second part describes a process which was used to implement test automation scheme for functional testing of LTE core network MME element. In implementation of the test automation scheme agile development models and Robot Framework test automation tool were used. In the third part two alternative models are presented for integrating this test automation scheme as part of a continuous integration process. As a result, the test automation scheme for functional testing was implemented. Almost all new functional level testing test cases can now be automated with this scheme. In addition, two models for integrating this scheme to be part of a wider continuous integration pipe were introduced. Also shift from usage of a traditional waterfall model to a new agile development based model in testing stated to be successful.
Resumo:
This master’s thesis is focused on power supply network disturbances and their effects on the frequency converter – one of the components of modern process crane electrical system. The most critical disturbance types, their causes and the effect they bring to crane electrical system was determined in this work. Variety of protective devices used for mitigation of disturbances is investigated. Device protection solutions for the frequency converter used in crane applications are presented. Analyses of the power supply requirements for frequency converter and various components of crane electrical system were carried out and as a result the crane power supply requirements list that guarantees normal crane operation was built. This list is to be included in crane projects for troubleshooting purposes in order to determine potentially dangerous network.
Resumo:
The aim of this thesis was to study network structures and modularity among biofuel heating system manufacturers in the Finnish bioenergy sector by utilizing the perspectives of numerous Finnish bioenergy specialists. The study is qualitative due to the fact that the research material was gathered with semi-structured theme interviews during May and June 2010. The research methodology used in the thesis combines conceptual and action-oriented approach. Networks, value nets, and modularity were studied from different perspectives. Three network and platform strategies were discovered and a general network structure was formed. Moreover, benefits and disadvantages of networks and modularity among biofuel heating system manufacturers were illustrated. The analysis provides a comprehensive perception of the industry. The results of the research were constructed by implementing existing theories into practice. Also future recommendations for the biofuel heating system manufacturers were given. The results can be considered to be beneficial because the number of previous studies about the subject is relatively small. The reliability of the study is eminent because the number of the interviews was inclusive.
Resumo:
The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h-1 can be carried out with the proposed flow-batch analyser.
Resumo:
The aim of this present work was to provide a more fast, simple and less expensive to analyze sulfur content in diesel samples than by the standard methods currently used. Thus, samples of diesel fuel with sulfur concentrations varying from 400 and 2500 mgkg-1 were analyzed by two methodologies: X-ray fluorescence, according to ASTM D4294 and by Fourier transform infrared spectrometry (FTIR). The spectral data obtained from FTIR were used to build multivariate calibration models by partial least squares (PLS). Four models were built in three different ways: 1) a model using the full spectra (665 to 4000 cm-1), 2) two models using some specific spectrum regions and 3) a model with variable selected by classic method of variable selection stepwise. The model obtained by variable selection stepwise and the model built with region spectra between 665 and 856 cm-1 and 1145 and 2717 cm-1 showed better results in the determination of sulfur content.
Resumo:
In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.