919 resultados para Arrowhead, interoperability, soa, internet of things, smart spaces, api, simulation
Resumo:
The present work aims to discuss the urban dimension of architecture and to investigate the role of the architectural spaces in the quality of life in between buildings and their environments. It investigates the transitional spaces between building and thoroughfare; building, thoroughfare and built environments located on the ground level of the buildings, and the potential they have to modify (individually or in groups) the environment where they are. For that, the research studies aspects of the architecture that urban buildings (individually or in groups) have and the inference of the morphology, building type and urban environment quality within the extended context of the Brazilian contemporary city. The analysis of the relation between building, thoroughfare and adjacent surroundings will be performed by the lights of, the evolution they have suffered since European urban spatial interventions that took place in the 19th Century; the morphological rupture on the traditional modern city of the 20th Century; the Brazilian experience focused on edifices, by showing analysis of a group of buildings, in their majority, iconic examples of Brazilian architecture from the 1930s onwards; and finally by an extensive investigation on the micro areas that have been selected in the Camburi region, in the city of Vitória-ES, focused on the characteristics of their architectural complex. As a preliminary conclusion, it can be stated that architecture cannot determine the quality in urban life and in its environments by itself, but because of its architectural and urban configuration of space, it may contribute to quality of environment in its surroundings
Resumo:
The Portuguese Energy Policy considers the development of a commercially viable and competitive market for energy performance contracting (EPC) as a main mechanism to achieve the objectives of energy efficiency improvement. This paper proposes a study to investigate how to achieve widespread adoption of energy performance contracting by means of system dynamics modelling and simulation. To explore and gather insights on this question, a system dynamics model representing the system of the Portuguese EPC market at industry level will be created. The simulation of that model will provide a helpful basis for analysing and explaining the development of key variables, and accelerating learning on the managerial, organizational and political adaptation processes that foster the diffusion of EPC adoption. The first phase of this research project aims at identifying and analysing the key factors and critical cause-effect relations that drive the adoption of EPC. With this purpose, a qualitative content analysis on relevant documents was performed and a set of interviews was conducted. That data was analysed to capture the critical variables and its interrelation to formulate a preliminary representation of the system structure as stock and flow diagrams.
Resumo:
The smart grid concept appears as a suitable solution to guarantee the power system operation in the new electricity paradigm with electricity markets and integration of large amounts of Distributed Energy Resources (DERs). Virtual Power Player (VPP) will have a significant importance in the management of a smart grid. In the context of this new paradigm, Electric Vehicles (EVs) rise as a good available resource to be used as a DER by a VPP. This paper presents the application of the Simulated Annealing (SA) technique to solve the Energy Resource Management (ERM) of a VPP. It is also presented a new heuristic approach to intelligently handle the charge and discharge of the EVs. This heuristic process is incorporated in the SA technique, in order to improve the results of the ERM. The case study shows the results of the ERM for a 33-bus distribution network with three different EVs penetration levels, i. e., with 1000, 2000 and 3000 EVs. The results of the proposed adaptation of the SA technique are compared with a previous SA version and a deterministic technique.
Resumo:
Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.
Resumo:
Mestrado em Engenharia Química. Ramo Tecnologias de Protecção Ambiental.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica na Área de Especialização de Energia
Resumo:
Relatório de Estágio para obtenção de grau de Mestre em Engenharia Civil Perfil de Edificações
Resumo:
I (Prática pedagógica)- Esta secção do Relatório de Estágio pretende apresentar elementos referentes ao Estágio do Ensino Especializado da Música no ensino do saxofone, efectuado na Escola de Música Luís António Maldonado Rodrigues, no ano lectivo 2012/2013. Neste estágio foram envolvidos e analisados três alunos, em níveis distintos de desenvolvimento, mas com orientações semelhantes no que respeita à organização do trabalho. Para cada aluno foram realizados trinta planos de aula, uma planificação anual e três gravações vídeo/áudio em contexto de sala de aula, permitindo uma análise e reflexão mais profunda do trabalho docente. A secção é composta pela caracterização da escola onde se realizou o estágio, através da sua contextualização/funcionamento, dos seus espaços e equipamentos, recursos humanos existentes e organização pedagógica. Posteriormente é efectuada a caracterização dos três alunos envolvidos no estágio, baseada na experiência docente e nos conhecimentos fornecidos pelas Unidades Curriculares do Mestrado em Ensino da Música. Seguidamente descrevem-se as práticas lectivas desenvolvidas ao longo do ano lectivo por parte do docente, incorporando linhas orientadoras da docência aplicadas na prática pedagógica. É feita uma análise crítica da actividade docente no âmbito do estágio do Ensino Especializado da Música, e, por último, uma conclusão desta primeira secção. .
Resumo:
This paper presents a systemic modeling for a PV system integrated into an electric grid. The modeling includes models for a DC-DC boost converter and a DC-AC two-level inverter. Classical or fuzzy PI controllers with pulse width modulation by space vector modulation associated with sliding mode control is used for controlling the PV system and power factor control is introduced at the output of the system. Comprehensive performance simulation studies are carried out with the modeling of the DC-DC boost converter followed by a two-level power inverter in order to compare the performance with the experimental results obtained during in situ operation with three commercial inverters. Also, studies are carried out to assess the quality of the energy injected into the electric grid in terms of harmonic distortion. Finally, conclusions regarding the integration of the PV system into the electric grid are presented. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
The process of resources systems selection takes an important part in Distributed/Agile/Virtual Enterprises (D/A/V Es) integration. However, the resources systems selection is still a difficult matter to solve in a D/A/VE, as it is pointed out in this paper. Globally, we can say that the selection problem has been equated from different aspects, originating different kinds of models/algorithms to solve it. In order to assist the development of a web prototype tool (broker tool), intelligent and flexible, that integrates all the selection model activities and tools, and with the capacity to adequate to each D/A/V E project or instance (this is the major goal of our final project), we intend in this paper to show: a formulation of a kind of resources selection problem and the limitations of the algorithms proposed to solve it. We formulate a particular case of the problem as an integer programming, which is solved using simplex and branch and bound algorithms, and identify their performance limitations (in terms of processing time) based on simulation results. These limitations depend on the number of processing tasks and on the number of pre-selected resources per processing tasks, defining the domain of applicability of the algorithms for the problem studied. The limitations detected open the necessity of the application of other kind of algorithms (approximate solution algorithms) outside the domain of applicability founded for the algorithms simulated. However, for a broker tool it is very important the knowledge of algorithms limitations, in order to, based on problem features, develop and select the most suitable algorithm that guarantees a good performance.
Resumo:
Dissertation presented to obtain a Ph.D. degree in Biology, speciality Microbiology, by Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
Mestrado em Engenharia Civil - Construções
Resumo:
Nesta dissertação pretende-se caracterizar o desempenho energético de um grande edifício de serviços existente, da tipologia ensino, avaliar e identificar potenciais medidas que melhorem aquele desempenho, permitindo, em complemento, determinar a sua classificação energética no âmbito da legislação vigente. A pertinência do estudo prende-se com a avaliação do desempenho energético dos edifícios e com o estudo de medidas de melhoria que permitam incrementar a eficiência energética, por recurso a um programa de simulação energética dinâmica certificado – DesignBuilder e tendo em conta a regulamentação portuguesa em vigor. Inicialmente procedeu-se à modelação do edifício com recurso ao programa DesignBuilder, e, simultaneamente, realizou-se um levantamento de todas as suas características ao nível de geometria, pormenores construtivos, sistemas AVAC e de iluminação e fontes de energia utilizadas. Com vista à caracterização do modo de operação do edifício, foi realizado um levantamento dos perfis reais de utilização em termos de ocupação, iluminação e equipamentos para os vários espaços. Foram realizadas medições de caudais de ar novo e da temperatura do ar, em alguns equipamentos e alguns espaços específicos. Foram realizadas medições em tempo real e leituras de contagens da energia eléctrica utilizada, quer em período de aulas quer em período de férias, que permitiram a desagregação das facturas da energia eléctrica que se apresentam globais para o campus do ISEP. Foram realizadas leituras de contagens de gás natural. Em sequência, foi realizada a simulação energética dinâmica com o intuito de ajustar o modelo criado aos consumos reais e de analisar medidas de melhoria que lhe conferissem um melhor desempenho energético. Essas medidas são agrupadas em quatro tipos: - Medidas de natureza comportamental; - Medidas de melhoria da eficiência energética nos sistemas de iluminação; - Medidas de melhoria de eficiência energética nos sistemas AVAC;- Medidas que visam a introdução de energias de fonte renovável; Em sequência, foi elaborada a simulação nominal e calculados os indicadores de eficiência energética com vista à respectiva classificação energética do edifício, tendo o edifício apresentado uma Classe Energética D de acordo com a escala do SCE. Finalmente, foi avaliado o impacto das diferentes medidas de melhoria identificadas e com potencial de aplicação, isto é, que apresentaram um retorno simples do investimento inferior a oito anos, tanto ao nível do desempenho energético real do edifício, como ao nível da sua classificação energética. De onde se concluiu que existe um potencial de 7% de redução nos consumos energéticos actuais do edifício e de 18% se o funcionamento do edifício for em pleno, ou seja, se todos os seus sistemas estiverem efectivamente em funcionamento, e que terá impacto na classificação energética alcançado uma Classe Energética C.
Resumo:
Os dispositivos móveis são pessoais, intransmissíveis e cada vez mais utilizados, tornando-se assim numa boa ferramenta para a realização de um conjunto de serviços na indústria hoteleira. Entre esses serviços que necessitam da identificação pessoal, encontram-se a possibilidade do cliente reservar um quarto ou utilizar o serviço de quartos. Atualmente é muito utilizado, nos locais de alojamento, um smart card que possibilite ao cliente ter acesso a alguns dos serviços disponíveis. O objetivo deste documento é apresentar uma alternativa ao sistema de cartões, utilizando para o efeito, dispositivos móveis. De modo a garantir a segurança e uma utilização semelhante ao sistema de cartões existentes foi utilizada a tecnologia NFC (Near Field Communication) que, ao permitir o modo de emulação de cartão, facilita a transação do sistema de smart card existente, para o da utilização de dispositivos móveis na realização das mesmas funções. Mais concretamente, será abordada a utilização de smartphones para o processo de abertura de portas. Para que exista uma melhor compreensão e para que haja um conhecimento das suas capacidades e limites foram estudados casos de uso da tecnologia NFC. Este documento apresenta ainda os processos de desenvolvimento de uma aplicação nativa para o sistema operativo Android, cujo objetivo é proporcionar ao cliente de um local de alojamento um novo modo de acesso ao quarto, utilizando a tecnologia NFC. Para além desta funcionalidade a aplicação permite ainda ao utilizador fazer reservas, fazer o check-in, fazer o check-out entre outras. Posteriormente serão apresentadas as conclusões e possíveis trabalhos futuros.
Resumo:
The implementation of smart homes allows the domestic consumer to be an active player in the context of the Smart Grid (SG). This paper presents an intelligent house management system that is being developed by the authors to manage, in real time, the power consumption, the micro generation system, the charge and discharge of the electric or plug-in hybrid vehicles, and the participation in Demand Response (DR) programs. The paper proposes a method for the energy efficiency analysis of a domestic consumer using the SCADA House Intelligent Management (SHIM) system. The main goal of the present paper is to demonstrate the economic benefits of the implemented method. The case study considers the consumption data of some real cases of Portuguese house consumption over 30 days of June of 2012, the Portuguese real energy price, the implementation of the power limits at different times of the day and the economic benefits analysis.