966 resultados para cyanoacetylene ro-vibrational spectroscopy spectral analysis
Resumo:
There were three principle aims to this thesis. Firstly, the acquisition protocols of clinical blood flow apparatus were investigated in order to optimise them for both cross-sectional and longitudinal application. Secondly, the effects of physiological factors including age and systematic circulation on ocular blood flow were investigated. Finally, the ocular perfusion characteristics of patients diagnosed with ocular diseases considered to be of a vascular origin were investigated. The principle findings of this work are:- 1) Optimisation of clinical investigationsPhotodiode sensitivity of the scanning laser Doppler flowmeter should be kept within a range of 70-150 DC when acquiring images of the retina and optic nerve head in order to optimise the reproducibility of capillary blood flow measures. Account of the physiological spatial variation in retinal blood flow measures can be made using standard analysis protocols of the scanning laser Doppler flowmeter combined with a local search strategy. Measurements of pulsatile ocular blood flow using the ocular blood flow analyser are reproducible, however this reproducibility can be improved when consecutive intraocular pressure pulses are used to calculate pulsatile ocular blood flow. Spectral analysis of the intraocular pressure pulse-wave is viable and identifies the first four harmonic components of the waveform. 2) Physiological variation in ocular perfusionAge results in a significant reduction in perfusion of the retinal microcirculation, which is not evident in larger vessel beds such as the choroid. Despite known asymmetry in the systemic vasculature, no evidence of interocular asymmetry in ocular perfusion is apparent. 3) Pathological variation in ocular perfusionIn primary open angle glaucoma, perfusion is reduced in the retinal microcirculation of patients classified as having early to moderate visual field defects. However, ocular pulsatility defects are masked when patients and subjects are matched for systemic variables (pulse rate and mean arterial pressure); differentiation is facilitated by the application of waveform analysis to the continuos intraocular pressure curve even in the early stages of disease. Diabetic patients with adequate glycaemic control, exhibit maintenance of macular blood flow, macular topography and visual function following phacoemulsification.
Resumo:
An initial aim of this project was to evaluate the conventional techniques used in the analysis of newly prepared environmentally friendly water-borne automotive coatings and compare them with solvent-borne coatings having comparable formulations. The investigation was carried out on microtuned layers as well as on complete automotive multi-layer paint systems. Methods used included the very traditional methods of gloss and hardness and the commonly used photo-oxidation index (from FTIR spectral analysis). All methods enabled the durability to weathering of the automotive coatings to be initially investigated. However, a primary aim of this work was to develop methods for analysing the early stages of chemical and property changes in both the solvent-borne and water-borne coating systems that take place during outdoor natural weathering exposures and under accelerated artificial exposures. This was achieved by using dynamic mechanical analysis (DMA), in both tension mode on the microtomed films (on all depths of the coating systems from the uppermost clear-coat right down to the electron-coat) and bending mode of the full (unmicrotomed) systems, as well as MALDI-Tof analysis on the movement of the stabilisers in the full systems. Changes in glass transition temperature and relative cross-link density were determined after weathering and these were related to changes in the chemistries of the binder systems of the coatings after weathering. Concentration profiles of the UV-stabilisers (UVA and HALS) in the coating systems were analysed as a consequence of migration in the coating systems in separate microtomed layers of the paint samples (depth profiling) after weathering and diffusion co-efficient and solubility parameters were determined for the UV stabilisers in the coating systems. The methods developed were used to determine the various physical and chemical changes that take place during weathering of the different (water-borne and solvent-borne) systems (photoxidation). The solvent-borne formulations showed less changes after weathering (both natural and accelerated) than the corresponding water-borne formulations due to the lower level of cross-links in the binders of the water-borne systems. The silver systems examined were more durable than the blue systems due to the reflecting power of the aluminium and the lower temperature of the silver coatings.
Resumo:
This thesis presents an approach to cutting dynamics during turning based upon the mechanism of deformation of work material around the tool nose known as "ploughing". Starting from the shearing process in the cutting zone and accounting for "ploughing", new mathematical models relating turning force components to cutting conditions, tool geometry and tool vibration are developed. These models are developed separately for steady state and for oscillatory turning with new and worn tools. Experimental results are used to determine mathematical functions expressing the parameters introduced by the steady state model in the case of a new tool. The form of these functions are of general validity though their coefficients are dependent on work and tool materials. Good agreement is achieved between experimental and predicted forces. The model is extended on one hand to include different work material by introducing a hardness factor. The model provides good predictions when predicted forces are compared to present and published experimental results. On the other hand, the extension of the ploughing model to taming with a worn edge showed the ability of the model in predicting machining forces during steady state turning with the worn flank of the tool. In the development of the dynamic models, the dynamic turning force equations define the cutting process as being a system for which vibration of the tool tip in the feed direction is the input and measured forces are the output The model takes into account the shear plane oscillation and the cutting configuration variation in response to tool motion. Theoretical expressions of the turning forces are obtained for new and worn cutting edges. The dynamic analysis revealed the interaction between the cutting mechanism and the machine tool structure. The effect of the machine tool and tool post is accounted for by using experimental data of the transfer function of the tool post system. Steady state coefficients are corrected to include the changes in the cutting configuration with tool vibration and are used in the dynamic model. A series of oscillatory cutting tests at various conditions and various tool flank wear levels are carried out and experimental results are compared with model—predicted forces. Good agreement between predictions and experiments were achieved over a wide range of cutting conditions. This research bridges the gap between the analysis of vibration and turning forces in turning. It offers an explicit expression of the dynamic turning force generated during machining and highlights the relationships between tool wear, tool vibration and turning force. Spectral analysis of tool acceleration and turning force components led to define an "Inertance Power Ratio" as a flank wear monitoring factor. A formulation of an on—line flank wear monitoring methodology is presented and shows how the results of the present model can be applied to practical in—process tool wear monitoring in • turning operations.
Resumo:
By spectral analysis, and using joint time-frequency representations, we present the theoretical basis to design invariant band-limited Airy pulses with an arbitrary degree of robustness, and an arbitrary range of single mode fiber chromatic dispersion. The numerically simulated examples confirm the theoretically predicted pulse partial invariance in the propagation of the pulse in the fiber.
Resumo:
Signal resolution in H NMR is limited primarily by multiplet structure. Recent advances in pure shift NMR, in which the effects of homonuclear couplings are suppressed, have allowed this limitation to be circumvented in 1D NMR, gaining almost an order of magnitude in spectral resolution. Here for the first time an experiment is demonstrated that suppresses multiplet structure in both domains of a homonuclear two-dimensional spectrum. The principle is demonstrated for the TOCSY experiment, generating a chemical shift correlation map in which a single peak is seen for each coupled relationship, but the principle is general and readily extensible to other homonuclear correlation experiments. Such spectra greatly simplify manual spectral analysis and should be well-suited to automated methods for structure elucidation. © 2010 American Chemical Society.
Resumo:
We present what is to our knowledge the first comprehensive investigation of the use of blazed fiber Bragg gratings (BFBGs) to interrogate wavelength division multiplexed (WDM) in-fiber optical sensor arrays. We show that the light outcoupled from the core of these BFBGs is radiated with sufficient optical power that it may be detected with a low-cost charge-coupled device (CCD) array. We present thorough system performance analysis that shows sufficient spectral-spatial resolution to decode sensors with a WDM separation of 75 ρm, signal-to-noise ratio greater than 45-dB bandwidth of 70 nm, and drift of only 0.1 ρm. We show the system to be polarization-state insensitive, making the BFBG-CCD spectral analysis technique a practical, extremely low-cost, alternative to traditional tunable filter approaches.
Resumo:
The crystal structure and magnetic properties of a penta-coordinate iron(III) complex of pyridoxal-4-methylthiosemicarbazone, [Fe(Hmthpy)Cl](CHCHSO), are reported. The synthesised ligand and the metal complex were characterised by spectroscopic methods (H NMR, IR, and mass spectroscopy), elemental analysis, and single crystal X-ray diffraction. The complex crystallises as dark brown microcrystals. The crystal data determined at 100(1) K revealed a triclinic system, space group P over(1, ¯) (Z = 2). The ONSCl geometry around the iron(III) atom is intermediate between trigonal bipyramidal and square pyramidal (t = 0.40). The temperature dependence of the magnetic susceptibility (5-300 K) is consistent with a high spin Fe(III) ion (S = 5/2) exhibiting zero-field splitting. Interpretation of these data yielded: D = 0.34(1) cm and g = 2.078(3). © 2007 Elsevier B.V. All rights reserved.
Resumo:
Cardiotocographic data provide physicians information about foetal development and permit to assess conditions such as foetal distress. An incorrect evaluation of the foetal status can be of course very dangerous. To improve interpretation of cardiotocographic recordings, great interest has been dedicated to foetal heart rate variability spectral analysis. It is worth reminding, however, that foetal heart rate is intrinsically an uneven series, so in order to produce an evenly sampled series a zero-order, linear or cubic spline interpolation can be employed. This is not suitable for frequency analyses because interpolation introduces alterations in the foetal heart rate power spectrum. In particular, interpolation process can produce alterations of the power spectral density that, for example, affects the estimation of the sympatho-vagal balance (computed as low-frequency/high-frequency ratio), which represents an important clinical parameter. In order to estimate the frequency spectrum alterations of the foetal heart rate variability signal due to interpolation and cardiotocographic storage rates, in this work, we simulated uneven foetal heart rate series with set characteristics, their evenly spaced versions (with different orders of interpolation and storage rates) and computed the sympatho-vagal balance values by power spectral density. For power spectral density estimation, we chose the Lomb method, as suggested by other authors to study the uneven heart rate series in adults. Summarising, the obtained results show that the evaluation of SVB values on the evenly spaced FHR series provides its overestimation due to the interpolation process and to the storage rate. However, cubic spline interpolation produces more robust and accurate results. © 2010 Elsevier Ltd. All rights reserved.
Resumo:
Cardiotocographic data provide physicians information about foetal development and, through assessment of specific parameters (like accelerations, uterine contractions, ...), permit to assess conditions such as foetal distress. An incorrect evaluation of foetal status can be of course very dangerous. In the last decades, to improve interpretation of cardiotocographic recordings, great interest has been dedicated to FHRV spectral analysis. It is worth reminding that FHR is intrinsically an uneven series and that to obtain evenly sampled series, many commercial cardiotocographs use a zero-order interpolation (storage rate of CTG data equal to 4 Hz). This is not suitable for frequency analyses because interpolation introduces alterations in the FHR power spectrum. In particular, this interpolation process can produce artifacts and an attenuation of the high-frequency components of the PSD that, for example, affects the estimation of the sympatho-vagal balance (SVB - computed as low-frequency/high-frequency ratio), which represents an important clinical parameter. In order to estimate the frequency spectrum alterations due to zero-order interpolation and other CTG storage rates, in this work, we simulated uneven FHR series with set characteristics, their evenly spaced versions (with different storage rates) and computed SVB values by PSD. For PSD estimation, we chose the Lomb method, as suggested by other authors in application to uneven HR series. ©2009 IEEE.
Resumo:
2000 Mathematics Subject Classification: 35B35, 35B40, 35Q35, 76B25, 76E30.
Resumo:
Михаил Константинов, Весела Пашева, Петко Петков - Разгледани са някои числени проблеми при използването на компютърната система MATLAB в учебната дейност: пресмятане на тригонометрични функции, повдигане на матрица на степен, спектрален анализ на целочислени матрици от нисък ред и пресмятане на корените на алгебрични уравнения. Причините за възникналите числени трудности могат да се обяснят с особеностите на използваната двоичната аритметика с плаваща точка.
Resumo:
In this study, an Atomic Force Microscopy (AFM) roughness analysis was performed on non-commercial Nitinol alloys with Electropolished (EP) and Magneto-Electropolished (MEP) surface treatments and commercially available stents by measuring Root-Mean-Square (RMS) , Average Roughness (Ra), and Surface Area (SA) values at various dimensional areas on the alloy surfaces, ranging from (800 x 800 nm) to (115 x 115µm), and (800 x 800 nm) to (40 x 40 µm) on the commercial stents. Results showed that NiTi-Ta 10 wt% with an EP surface treatment yielded the highest overall roughness, while the NiTi-Cu 10 wt% alloy had the lowest roughness when analyzed over (115 x 115 µm). Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) analysis revealed unique surface morphologies for surface treated alloys, as well as an aggregation of ternary elements Cr and Cu at grain boundaries in MEP and EP surface treated alloys, and non-surface treated alloys. Such surface micro-patterning on ternary Nitinol alloys could increase cellular adhesion and accelerate surface endothelialization of endovascular stents, thus reducing the likelihood of in-stent restenosis and provide insight into hemodynamic flow regimes and the corrosion behavior of an implantable device influenced from such surface micro-patterns.
Resumo:
Located on the western edge of the Brazilian northeast, the Parnaíba Basin is an intra cratonic basin with oil production. This study aims at understanding its genesis and evolution, using aeromagnetic and gravity data. We used the spectral analysis of aeromagnetic data to map the depth to the bottom of the magnetic sources in order to assimilate this depth with the depth of the Curie isotherm, and infer the geothermal gradient. Using the spectral analysis technique, we succeeded in mapping the surface of the depth to the bottom of magnetic sources (SBFM), which marks the depth that occur magnetization. In the Parnaíba Basin the SBFM presented depths around -20,5 and -28,5 , which was consistent with an inversion of the same dataset using the technique of Magnetization Vector Inversion (MVI). Furthermore, SBFM topography correlates well with Moho depth, which was estimated from satellite gravimetric data from the GOCE mission (Gravity Field and Steady-State Ocean Circulation Explorer). Assuming that SBFM coincides with the Curie isotherm of magnetite (ICM), defined as the surface at which magnetite ( ) looses its ferromagnetic properties, it was possible to estimate the geothermal gradient. The geothermal gradient in the basin showed values between 19.2 and 26.5 , allowing to estimate the heat flow for the Parnaíba basin after assuming a conductivity of 2.69 . The resulting heat flow values ranged between 51.6 and 71.3 , which is consistent with values found in other works throughout the South American continent. Lithospheric thickness using an empirical relationship, finding values between -65.8 and -89.2 . We propose that thermal structure of Parnaíba basin is influenced by a deep thermal anomaly. This anomaly has heated the lithosphere beneath the basin and has resulted in relatively thin values for the lithospheric thickness and relatively high surface heat flow values. The origin of the anomaly is not clear, but the correlation between Curie depth and Moho topography, suggests that tectonic extension processes could have played a role.
Resumo:
Chitosan is a polymer biocompatibility and biodegradability widely used in drug delivery systems. The co-crosslinking of chitosan with sodium sulfate and genipin, to form particulate systems is related of making them more resistant to acidic pH and to modulate the release kinetics for the oral route. Triamcinolone is a glucocorticoid with anti-inflammatory and immunosuppressive actions. The nanoparticles were prepared by co-crosslinking and characterized for particle size, PDI, zeta potential, crosslinking degree, encapsulation rate, morphology, infrared spectroscopy, thermal analysis, release kinetics and cells studies. The nanoparticles were prepared initially without genipin with sodium sulphate and the particles parameters were monitored in function of different ratio of drug / polymer, different concentrations of sodium sulfate and polysorbate 80 and the drip mode of crosslinkers on polymers. After optimizing conditions, the chosen system parameters without genipin included mean diameter of 312.20 ± 5.70 nm, PDI 0.342 ± 0.013 and zeta potential of 20.18 ± 2.28 mV. The genipin was introduced into the system analyzing different concentrations (0.5, 1.0 and 2.0 mM) and crosslinking times (3, 6, 12 and 24 h). Evaluating crosslinking time with genipin (0.5 mM) it was showed that varying the genipin reaction time the systems size ranged from 235.1 to 334.4 nm, the PDI from 0.321 to 0.392 and zeta potential 20.92 to 30.39 mV. The crosslinking degree that coud vary from 14 to 30 %. Nanoparticles without genipina, 6 h and 24 h crosslinking time were dried by spray-drying method. Analysis by scanning electron micrograph (SEM) revealed that the microparticles showed spherical morphology. The encapsulation rate was 75 ± 2.3 % using validated HPLC methodology. The infrared analysis showed chemical interactions between the components of the formulation. Thermal analysis showed that systems with a higher degree of crosslinking had a higher thermal stability. On release kinetics, increasing the degree of crosslinking was able to decrease the concentration and rate of release of triamcinolone. In studies with liver cancer cells (HepG2) and colon (HT-29), the microparticulate prepared with triamcinolone and 24 h of crosslinking with genipin showed a potential for antitumor activity in hepatic cell line HepG2. Therefore, a new delivery system for triamcinolone on polymeric nanoparticles of chitosan cocrosslinked with genipin and sodium sulfate was obtained with hepatic antitumor potential.
Resumo:
Metal Organic Frameworks (MOFs) are hybrids materials, often crystalline, consisting of metal or metal clusters, connected by polytopic organic ligands repetitively, leading to structures, usually porous. In this work, MOFs based on lanthanide ions (La3+ and Gd3+) and dicarboxylate type of ligands (isophthalic and terephthalic acids), were synthesized by hydrothermal, solvothermal and hydro(solvo)thermal methods. The effects of the synthetic route as well as the type of heating, conventional or by microwave, on the structure and properties of MOFs were studied. The powder samples obtained were characterized by X-ray diffraction, infrared spectroscopy, thermal analysis and scanning electron microscopy. The results suggest that the addition of an organic or inorganic base is needed to promote the deprotonation of the ligand, since in the samples prepared by the hydrothermal method, without the use of a base, no formation of the metalorganic framework was observed. On the other hand, the presence of DMF as solvent or cosolvent, afforded the deprotonation of the ligand with the consequent formation of MOFs. At least two different crystalline structures were identified for the samples prepared with terephthalic acid. These samples are isostructural with those reported for phases Eu(1,3-BDC)DMF, Eu2(1,4-BDC)3 (DMF)2 and Tb(1,4-BDC)H2O. The presence of water in the reaction medium in the hydro(solvo)thermal method, provoked the growth of the structure different from that observed in the absence of water. This can be explained by the difference in the coordination mode of water and DMF to lanthanide ions. Although not identified by XRD, the samples prepared with isophthalic acid, also present metalorganic structures, which was confirmed by the presence of the characteristic displacement of the carbonyl group band in their infrared spectra, compared to the spectrum of the pure ligand. This shift was also observed in the samples prepared with terephthalic acid. Thermal analisys shows that the metal organic frameworks do not collapse occurs at a temperature below 430°C.The analysis of scanning electron microscopy suggests that the morphology of powders is highly dependent on the type of heating used, conventional or by microwave.