982 resultados para MECHANICAL SYSTEMS
Resumo:
Purpose: To evaluate the effect of the opaque layer firing temperature and mechanical and thermal cycling on the flexural strength of a ceramic fused to commercial cobalt-chromium alloy (Co-Cr). The hypotheses were that higher opaque layer temperatures increase the metal/ceramic bond strength and that aging reduces the bond strength. Materials and Methods: Metallic frameworks (25 x 3 x 0.5 mm(3); ISO 9693) (N = 60) were cast in Co-Cr and airborne-particle abraded (Al(2)O(3): 150 mu m) at the central area of the frameworks (8 x 3 mm(2)) and divided into three groups (N = 20), according to the opaque layer firing temperature: Gr1 (control)-900 degrees C; Gr2-950 degrees C; Gr3-1000 degrees C. The opaque ceramic (Opaque, Vita Zahnfabrick, Bad Sackingen, Germany) was applied, and the glass ceramic (Vita Omega 900, Vita Zahnfabrick) was fired onto it (thickness: 1 mm). While half the specimens from each group were randomly tested without aging (water storage: 37 degrees C/24 hours), the other half were mechanically loaded (20,000 cycles; 50 N load; distilled water at 37 degrees C) and thermocycled (3000 cycles; 5 degrees C to 55 degrees C, dwell time: 30 seconds). After the flexural strength test, failure types were noted. The data were analyzed using 2-way ANOVA and Tukey`s test (alpha = 0.05). Results: Gr2 (19.41 +/- 5.5 N) and Gr3 (20.6 +/- 5 N) presented higher values than Gr1 (13.3 +/- 1.6 N) (p = 0.001). Mechanical and thermal cycling did not significantly influence the mean flexural strength values (p > 0.05). Increasing the opaque layer firing temperature improved the flexural bond strength values (p < 0.05). The hypotheses were partially accepted. Conclusion: Increasing of the opaque layer firing temperature improved the flexural bond strength between ceramic fused to Co-Cr alloy.
Resumo:
Bovine pericardium, for cardiac valve fabrication, was coated with either chitosan or silk fibroin film. In vitro calcification tests of coated and non coated bovine pericardium were performed in simulated body fluid solution in order to investigate potential alternatives to minimize calcification on implanted heart valves. Complementary, morphology was assessed by scanning electron microscopy - SEM; X-ray diffraction (XRD) and infrared spectroscopy (FTIR-ATR) were performed for structural characterization of coatings and biocompatibility of chitosan. Silk fibroin films were assayed by in vitro cytotoxicity and endothelial cell growth tests. Bovine pericardium coated with silk fibroin or chitosan did not present calcification during in vitro calcification tests, indicating that these biopolymeric coatings do not induce bovine pericardium calcification. Chitosan and silk fibroin films were characterized as non cytotoxic and silk fibroin films presented high affinity to endothelial cells. The results indicate that bovine pericardium coated with silk fibroin is a potential candidate for cardiac valve fabrication, since the affinity of silk fibroin to endothelial cells can be explored to induce the tissue endothelization and therefore, increase valve durability by increasing their mechanical resistance and protecting them against calcification. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Background: Aortic valve replacement with a cryopreserved aortic homograft (CH) is an attractive alternative to bioprosthesis implantation. The aim of the study was to compare the hemodynamic performance of CH implanted with aortic root inclusion compared to prototype stentless (SS) bioprosthesis, standard stented (SD) bioprosthesis, and a native aortic valve. Methods: Hemodynamics and Doppler echocardiographic measurements such as left ventricular ejection fraction, aortic valve orifice area index (AVOAI), mean and maximal transvalvular gradients, were obtained at rest and immediately after exercise in 28 patients after aortic valve replacement with CH (n = 10), SS (n = 9), or SD (n = 9), and in a control group (CG) of 15 normal volunteers. Results: Rest and peak exercise heart rate and workload achieved were not different among the groups. Baseline AVOAI was larger for CH and CG compared to SS and SD groups (P < 0.05). Maximal and mean transvalvular pressure gradients at rest were lower for CH compared to SS and SD groups (P < 0.05), but higher than CG (P < 0,05). Conclusion: Implanted aortic CH had better hemodynamic performance than SS and SD bioprosthesis and similar to native normal aortic valves, both at rest and immediately after exercise. (ECHOCARDIOGRAPHY, Volume 26, November 2009).
Resumo:
BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)
Resumo:
Objective: To compare the performance of patients with obsessive-compulsive disorder (OCD) refractory to conventional treatments to healthy controls according to the Frontal Systems Behaviour Scale (FrSBe), comparing the scale scores within each group (Self or Family) and correlating FrSBe with Y-BOCS, DY-BOCS, tic disorder and age of first symptoms. Method: Twenty OCD patients and 20 healthy controls were assessed using the FrSBe, a scale designed to evaluate frontal syndromes. Results: The patients had higher scores when compared with the control group (p value .001) in terms of total score on the scale for both profile forms (Self and Family). In addition, there was a significant difference between the scores reported by the patients and their respective relatives. However, no correlation was observed between the scale and the other variables. Conclusions: The scale was able to clearly differentiate patients with OCD from healthy controls. This finding suggests that the FrSBe can be used not only in neurologic patients but also in psychiatric cases such as refractory OCD.
Resumo:
PURPOSE: To compare mechanical and ethanol epithelial removal with respect to myofibroblast development and haze formation after photorefractive keratectomy (PRK). METHODS: Seventeen rabbits underwent mechanical or ethanol debridement, and the opposite eye of each rabbit served as an unwounded control. In both groups, the epithelium was removed with a spatula and discarded. A -9.00-diopter PRK was performed in each eye. The level of haze in each cornea at 4 weeks was graded at the slit-lamp microscope according to the Fantes scale. Myofibroblast generation was detected with immunocytochemistry for alpha-smooth muscle actin (alpha-SMA) and cells were quantitatively analyzed. RESULTS: No difference was noted between the two groups in alpha-SMA + myofibroblasts 4 weeks after surgery (43.6 +/- 2.0/400X field and 45.7 +/- 4.8/400X field in ethanol and mechanical groups, respectively) (P=.10). A slight difference was noted but did not reach statistical significance with regard to stromal haze between ethanol and mechanical groups (2.0 +/- 0.5 and 2.3 +/- 0.4, respectively, P=.063). The ethanol and mechanical groups were statistically different when compared to controls regarding stromal haze and alpha-SMA+ cells (P <.0001 for all comparisons). CONCLUSIONS:No difference was noted in clinical haze or myofibroblast generation between corneas that had PRK with mechanical,or ethanol epithelial debridement. [J Refract Surg., 2008;24:923-927.]