989 resultados para Implant surface


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss the relation between continuum bound states (CBSs) localized on a defect, and surface states of a finite periodic system. We model an experiment of Capasso et al. [F. Capasso, C. Sirtori, J. Faist, D. L. Sivco, S-N. G. Chu, and A. Y. Cho, Nature (London) 358, 565 (1992)] using the transfer-matrix method. We compute the rate for intrasubband transitions from the ground state to the CBS and derive a sum rule. Finally we show how to improve the confinement of a CBS while keeping the energy fixed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For successful treatment of prosthetic joint infection, the identification of the infecting microorganism is crucial. Cultures of synovial fluid and intraoperative periprosthetic tissue represent the standard method for diagnosing prosthetic joint infection. Rapid and accurate diagnostic tools which can detect a broad range of causing microorganisms and their antimicrobial resistance are increasingly needed. With newer diagnostic techniques, such as sonication of removed implants, microcalorimetry, molecular methods and mass spectrometry, the sensitivity has been significantly increased. In this article, we describe the conventional and newer diagnostic techniques with their advantages and potential future applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze how the spatial localization properties of pairing correlations are changing in a major neutron shell of heavy nuclei. It is shown that the radial distribution of the pairing density depends strongly on whether the chemical potential is close to a low or a high angular momentum level and has little sensitivity to whether the pairing force acts at the surface or in the bulk. The pairing density averaged over one major shell is, however, rather flat, exhibiting little dependence on the pairing force. Hartree-Fock-Bogoliubov calculations for the isotopic chain 100-132Sn are presented for demonstration purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We comment on a recent paper by Uma Maheswari et al. in which it is claimed that quantal calculations of the half-infinite nuclear matter, in contrast to semiclassical approximations, exhibit an unusually strong dependence of the 90%10% surface thickness of the density profile on the Fermi momentum kF at saturation. This conclusion was carried over to the surface incompressibility. On the contrary we find essential agreement between semiclassical and quantal results and very weak dependence on kF of the quantities in question.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the long-term success rate and complications of nonpenetrating deep sclerectomy with collagen implant in open-angle glaucoma. PATIENTS AND METHODS: Clinical, prospective, monocentric, nonrandomized, unmasked study on 105 patients with medically uncontrolled glaucoma. A standard procedure deep sclerectomy with collagen implant was performed. Complete examinations were performed before surgery and postoperatively at 1 and 7 days; 1, 2, 3, 6, 9, and 12 months and then every 6 months during the 10 following years. RESULTS: The mean follow-up was 101.5+/-43.1 (3 to 144) months [mean+/-SD, (range)]. The preoperative intraocular pressure (IOP) was 26.8+/-7.7 (14 to 52) mm Hg and the best-corrected visual acuity 0.71+/-0.33 (0.02 to 1.5). Ten years after surgery IOP was 12.2+/-4.7 (6 to 20) mm Hg and best-corrected visual acuity 0.63+/-0.34 (0.01 to 1.2) (number of remaining patients=52). The mean number of medications per patient went from 2.3+/-0.7 (1 to 4) down to 1.3+/-1.1 (0 to 3). An IOP <or=21 mm Hg without medication was achieved in 47.7% patients and in 89% with or without treatment. One major complication was reported. Goniopuncture was performed in 61 eyes (59.8%), 5-fluorouracil treatment given to 25 patients postoperatively and included needling (n=5). CONCLUSIONS: On the basis of a 10-year follow-up deep sclerectomy with collagen implant demonstrated its efficacy in controlling IOP with few postoperative complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Comment on the Letter by Mark Mineev-Weinstein, Phys. Rev. Lett. 80, 2113 (1998). The authors of the Letter offer a Reply.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that small amounts of 3He atoms, added to a 4He drop deposited on a flat cesium surface at zero temperature, populate bound states localized at the contact line. These edge states show up for drops large enough to develop well defined surface and bulk regions together with a contact line, and they are structurally different from the well-known Andreev states that appear at the free surface and at the liquid-solid interface of films. We illustrate the one-body density of 3He in a drop with 1000 4He atoms, and show that for a sufficiently large number of impurities the density profiles spread beyond the edge, coating both the curved drop surface and its flat base and eventually isolating it from the substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a numerical study of classical particles diffusing on a solid surface. The particles motion is modeled by an underdamped Langevin equation with ordinary thermal noise. The particle-surface interaction is described by a periodic or a random two-dimensional potential. The model leads to a rich variety of different transport regimes, some of which correspond to anomalous diffusion such as has recently been observed in experiments and Monte Carlo simulations. We show that this anomalous behavior is controlled by the friction coefficient and stress that it emerges naturally in a system described by ordinary canonical Maxwell-Boltzmann statistics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the singular effects of vanishingly small surface tension on the dynamics of finger competition in the Saffman-Taylor problem, using the asymptotic techniques described by Tanveer [Philos. Trans. R. Soc. London, Ser. A 343, 155 (1993)] and Siegel and Tanveer [Phys. Rev. Lett. 76, 419 (1996)], as well as direct numerical computation, following the numerical scheme of Hou, Lowengrub, and Shelley [J. Comput. Phys. 114, 312 (1994)]. We demonstrate the dramatic effects of small surface tension on the late time evolution of two-finger configurations with respect to exact (nonsingular) zero-surface-tension solutions. The effect is present even when the relevant zero-surface-tension solution has asymptotic behavior consistent with selection theory. Such singular effects, therefore, cannot be traced back to steady state selection theory, and imply a drastic global change in the structure of phase-space flow. They can be interpreted in the framework of a recently introduced dynamical solvability scenario according to which surface tension unfolds the structurally unstable flow, restoring the hyperbolicity of multifinger fixed points.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT : Background : The aim of this study was to evaluate the midterm biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. Methods : Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. [OP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. Results : For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. Conclusions : The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crash Rates and Crash Densities on Secondary Roads in Iowa by Surface Type produced by the Iowa Department of Transportation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A partial review is proposed on the existing literature for the research performed in orthopedic implant used as drug delivery system. In the first part, an evaluation is given on the clinical need to deliver a drug in the surrounding of an implant. Secondly, a review of the clinical situation is developed for implants already used as drug delivery system. Experimental works performed for local delivery are reported. In particular, a description is given on the in vitro and in vivo studies where the implant is coated with different proteins or drugs. Finally, a conclusion is proposed on the next step in the development of orthopedic implant as drug delivery system mentioning also the industrial situation.