983 resultados para Distance measuring equipment (DME)
Resumo:
The transient charge response Q(t) of a two-dimensional electron gas (2DEG) in GaAs/AlxGa1-xAs heterostructures to a small pulse of the gate voltage, applied between the top gate and source electrodes in a Corbino structure, was employed to directly measure the effective diffusion constant of a 2DEG in the quantum Hall regime. The measured diffusion constant D showed a drastic change as the magnetic field was swept through the integer fillings of the Landau levels.
Resumo:
The rate equations used for measuring spontaneous emission factor beta is examined through the comparison of numerical results, The results show that beta obtained by using total spontaneous emission rate R(sp) = N/tau sp is about double of that using R(sp) = BN2, The magnitude difference between the measured beta and that predicted by classical theory [8] will disappear by using more reasonable R(sp) = BN2. The results also show that the magnitude of beta may be underestimated by ignoring the nonradiative recombination rates.
Resumo:
In a practical coupling system, a cylindrical microlens is used to collimate the emission of a high powerlaser diode (LD) in the dimension perpendicular to the junction plane. Using passive alignment, the LD isplaced in the focus of the cylindrical microlens generally, regardless of the performance of the multimodeoptical fiber and the LD. In this paper, a more complete analysis is arrived at by ray-tracing technique,by which the angle θ of the ray after refraction is computed as a function of the angle θo of the ray beforerefraction. The focus of the cylindrical microlens is not always the optimal position of the LD. In fact, inorder to achieve a higher coupling efficiency, the optimal distance from the LD to the cylindrical microlensis dependent on not only the radius R and the index of refraction n of the cylindrical microlens, but alsothe divergence angle of the LD in the dimension perpendicular to the junction plane and the numericalaperture (NA) of the multimode optical fiber. The results of this discussion are in good agreement withexperimental results.
Resumo:
The design and fabrication of 1550 nm semiconductor optical amplifiers (SOAs) and the characteristics of the fabricated SOA are reported. A novel gain measurement technique based on the integrations of the product of emission spectrum and a phase function over one mode interval is proposed for Fabry-Perot semiconductor lasers.
Resumo:
An external cavity semiconductor laser interferometer used to measure far distance micro-vibration in real time is proposed. In the interferometer, a single longitudinal mode and excellent coherent characteristic grating external cavity semiconductor laser is constructed and acted as a light source and a phase compensator. Its coherent length exceeds 200 meters. The angle between normal and incidence beam of the far object is allowed to change in definite range during the measurement with this interferometer, and this makes the far distance interference measurement easier and more convenient. Also, it is not required to keep the amplitudes of the first and second harmonic components equal, and then the dynamic range is increased. A feedback control system is used to compensate the phase disturbance between the two interference beams introduced by environmental vibration.
Resumo:
HIRFL-CSR工程对CSRe冷却装置电子冷却部分的控制系统在实时性和可靠性方面提出了非常高的要求。电子冷却工作环境复杂,各种干扰难以预测。从电子冷却的控制系统改进出发,以实现电子冷却的自动调束为目标,以高端FPGA和ARM嵌入式系统为基础,采用P2P通讯技术和神经元网络算法来实现对电子冷却的自动控制。该控制系统对电子冷却控制的完善提供了先进的硬件平台和软件实现方案。
Resumo:
介绍了一种基于一线总线数字温度传感器的HIFRL-CSR循环冷却水温度远程测量系统,阐述了以DT400模块为核心的温度测量的硬件模块和软件设计。该系统具有测温精度高、易扩展性、低成本、低功耗、可靠性高、抗干扰能力强等特点,根据不同需要可应用于多种温度测量系统中。