924 resultados para paediatric cervical spine


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine if multi–detector row computed tomography (CT) can replace conventional radiography and be performed alone in severe trauma patients for the depiction of thoracolumbar spine fractures. MATERIALS AND METHODS: One hundred consecutive severe trauma patients who underwent conventional radiography of the thoracolumbar spine as well as thoracoabdominal multi–detector row CT were prospectively identified. Conventional radiographs were reviewed independently by three radiologists and two orthopedic surgeons; CT images were reviewed by three radiologists. Reviewers were blinded both to one another’s reviews and to the results of initial evaluation. Presence, location, and stability of fractures, as well as quality of reviewed images, were assessed. Statistical analysis was performed to determine sensitivity and interobserver agreement for each procedure, with results of clinical and radiologic follow-up as the standard of reference. The time to perform each examination and the radiation dose involved were evaluated. A resource cost analysis was performed. RESULTS: Sixty-seven fractured vertebrae were diagnosed in 26 patients. Twelve patients had unstable spine fractures. Mean sensitivity and interobserver agreement, respectively, for detection of unstable fractures were 97.2% and 0.951 for multi–detector row CT and 33.3% and 0.368 for conventional radiography. The median times to perform a conventional radiographic and a multi–detector row CT examination, respectively, were 33 and 40 minutes. Effective radiation doses at conventional radiography of the spine and thoracoabdominal multi–detector row CT, respectively, were 6.36 mSv and 19.42 mSv. Multi–detector row CT enabled identification of 146 associated traumatic lesions. The costs of conventional radiography and multi–detector row CT, respectively, were $145 and $880 per patient. CONCLUSION: Multi–detector row CT is a better examination for depicting spine fractures than conventional radiography. It can replace conventional radiography and be performed alone in patients who have sustained severe trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dual energy X-ray absorptiometry (DXA) is widely accepted as the reference method for diagnosis and monitoring of osteoporosis and for assessment of fracture risk, especially at hip. However, axial-DXA is not suitable for mass screening, because it is usually confined to specialized centers. We propose a two-step diagnostic approach to postmenopausal osteoporosis: the first step, using an inexpensive, widely available screening technique, aims at risk stratification in postmenopausal women; the second step, DXA of spine and hip is applied only to potentially osteoporotic women preselected on the basis of the screening measurement. In a group of 110 healthy postmenopausal woman, the capability of various peripheral bone measurement techniques to predict osteoporosis at spine and/or hip (T-score < -2.5SD using DXA) was tested using receiver operating characteristic (ROC) curves: radiographic absorptiometry of phalanges (RA), ultrasonometry at calcaneus (QUS. CALC), tibia (SOS.TIB), and phalanges (SOS.PHAL). Thirty-three women had osteoporosis at spine and/or hip with DXA. Areas under the ROC curves were 0.84 for RA, 0.83 for QUS.CALC, 0.77 for SOS.PHAL (p < 0.04 vs RA) and 0.74 for SOS.TIB (p < 0.02 vs RA and p = 0.05 vs QUS.CALC). For levels of sensitivity of 90%, the respective specificities were 67% (RA), 64% (QUS.CALC), 48% (SOS.PHAL), and 39% (SOS.TIB). In a cost-effective two-step, the price of the first step should not exceed 54% (RA), 51% (QUS.CALC), 42% (SOS.PHAL), and 25% (SOS.TIB). In conclusion, RA, QUS.CALC, SOS.PHAL, and SOS.TIB may be useful to preselect postmenopausal women in whom axial DXA is indicated to confirm/exclude osteoporosis at spine or hip.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One goal of interbody fusion is to increase the height of the degenerated disc space. Interbody cages in particular have been promoted with the claim that they can maintain the disc space better than other methods. There are many factors that can affect the disc height maintenance, including graft or cage design, the quality of the surrounding bone and the presence of supplementary posterior fixation. The present study is an in vitro biomechanical investigation of the compressive behaviour of three different interbody cage designs in a human cadaveric model. The effect of bone density and posterior instrumentation were assessed. Thirty-six lumbar functional spinal units were instrumented with one of three interbody cages: (1) a porous titanium implant with endplate fit (Stratec), (2) a porous, rectangular carbon-fibre implant (Brantigan) and (3) a porous, cylindrical threaded implant (Ray). Posterior instrumentation (USS) was applied to half of the specimens. All specimens were subjected to axial compression displacement until failure. Correlations between both the failure load and the load at 3 mm displacement with the bone density measurements were observed. Neither the cage design nor the presence of posterior instrumentation had a significant effect on the failure load. The loads at 3 mm were slightly less for the Stratec cage, implying lower axial stiffness, but were not different with posterior instrumentation. The large range of observed failure loads overlaps the potential in vivo compressive loads, implying that failure of the bone-implant interface may occur clinically. Preoperative measurements of bone density may be an effective tool to predict settling around interbody cages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we propose a simple model for the coupling behavior of the human spine for an inverse kinematics framework. Our spine model exhibits anatomically correct motions of the vertebrae of virtual mannequins by coupling standard swing and revolute joint models. The adjustement of the joints is made with several simple (in)equality constraints, resulting in a reduction of the solution space dimensionality for the inverse kinematics solver. By reducing the solution space dimensionality to feasible spine shapes, we prevent the inverse kinematics algorithm from providing infeasible postures for the spine.In this paper, we exploit how to apply these simple constraints to the human spine by a strict decoupling of the swing and torsion motion of the vertebrae. We demonstrate the validity of our approach on various experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare the effects of antiplatelets and anticoagulants on stroke and death in patients with acute cervical artery dissection. DESIGN Systematic review with Bayesian meta-analysis. DATA SOURCES The reviewers searched MEDLINE and EMBASE from inception to November 2012, checked reference lists, and contacted authors. STUDY SELECTION Studies were eligible if they were randomised, quasi-randomised or observational comparisons of antiplatelets and anticoagulants in patients with cervical artery dissection. DATA EXTRACTION Data were extracted by one reviewer and checked by another. Bayesian techniques were used to appropriately account for studies with scarce event data and imbalances in the size of comparison groups. DATA SYNTHESIS Thirty-seven studies (1991 patients) were included. We found no randomised trial. The primary analysis revealed a large treatment effect in favour of antiplatelets for preventing the primary composite outcome of ischaemic stroke, intracranial haemorrhage or death within the first 3 months after treatment initiation (relative risk 0.32, 95% credibility interval 0.12 to 0.63), while the degree of between-study heterogeneity was moderate (τ(2) = 0.18). In an analysis restricted to studies of higher methodological quality, the possible advantage of antiplatelets over anticoagulants was less obvious than in the main analysis (relative risk 0.73, 95% credibility interval 0.17 to 2.30). CONCLUSION In view of these results and the safety advantages, easier usage and lower cost of antiplatelets, we conclude that antiplatelets should be given precedence over anticoagulants as a first line treatment in patients with cervical artery dissection unless results of an adequately powered randomised trial suggest the opposite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate fixation properties of a new intervertebral anchored fusion device and compare these with ventral locking plate fixation. STUDY DESIGN: In vitro biomechanical evaluation. ANIMALS: Cadaveric canine C4-C7 cervical spines (n = 9). METHODS: Cervical spines were nondestructively loaded with pure moments in a nonconstraining testing apparatus to induce flexion/extension while angular motion was measured. Range of motion (ROM) and neutral zone (NZ) were calculated for (1) intact specimens, (2) specimens after discectomy and fixation with a purpose-built intervertebral fusion cage with integrated ventral fixation, and (3) after removal of the device and fixation with a ventral locking plate. RESULTS: Both fixation techniques resulted in a decrease in ROM and NZ (P < .001) compared with the intact segments. There were no significant differences between the anchored spacer and locking plate fixation. CONCLUSION: An anchored spacer appears to provide similar biomechanical stability to that of locking plate fixation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION There are limited data on paediatric HIV care and treatment programmes in low-resource settings. METHODS A standardized survey was completed by International epidemiologic Databases to Evaluate AIDS paediatric cohort sites in the regions of Asia-Pacific (AP), Central Africa (CA), East Africa (EA), Southern Africa (SA) and West Africa (WA) to understand operational resource availability and paediatric management practices. Data were collected through January 2010 using a secure, web-based software program (REDCap). RESULTS A total of 64,552 children were under care at 63 clinics (AP, N=10; CA, N=4; EA, N=29; SA, N=10; WA, N=10). Most were in urban settings (N=41, 65%) and received funding from governments (N=51, 81%), PEPFAR (N=34, 54%), and/or the Global Fund (N=15, 24%). The majority were combined adult-paediatric clinics (N=36, 57%). Prevention of mother-to-child transmission was integrated at 35 (56%) sites; 89% (N=56) had access to DNA PCR for infant diagnosis. African (N=40/53) but not Asian sites recommended exclusive breastfeeding up until 4-6 months. Regular laboratory monitoring included CD4 (N=60, 95%), and viral load (N=24, 38%). Although 42 (67%) sites had the ability to conduct acid-fast bacilli (AFB) smears, 23 (37%) sites could conduct AFB cultures and 18 (29%) sites could conduct tuberculosis drug susceptibility testing. Loss to follow-up was defined as >3 months of lost contact for 25 (40%) sites, >6 months for 27 sites (43%) and >12 months for 6 sites (10%). Telephone calls (N=52, 83%) and outreach worker home visits to trace children lost to follow-up (N=45, 71%) were common. CONCLUSIONS In general, there was a high level of patient and laboratory monitoring within this multiregional paediatric cohort consortium that will facilitate detailed observational research studies. Practices will continue to be monitored as the WHO/UNAIDS Treatment 2.0 framework is implemented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The paper's aim is to review dentin hypersensitivity (DHS), discussing pain mechanisms and aetiology. MATERIALS AND METHODS Literature was reviewed using search engines with MESH terms, DH pain mechanisms and aetiology (including abrasion, erosion and periodontal disease). RESULTS The many hypotheses proposed for DHS attest to our lack of knowledge in understanding neurophysiologic mechanisms, the most widely accepted being the hydrodynamic theory. Dentin tubules must be patent from the oral environment to the pulp. Dentin exposure, usually at the cervical margin, is due to a variety of processes involving gingival recession or loss of enamel, predisposing factors being periodontal disease and treatment, limited alveolar bone, thin biotype, erosion and abrasion. CONCLUSIONS The current pain mechanism of DHS is thought to be the hydrodynamic theory. The initiation and progression of DHS are influenced by characteristics of the teeth and periodontium as well as the oral environment and external influences. Risk factors are numerous often acting synergistically and always influenced by individual susceptibility. CLINICAL RELEVANCE Whilst the pain mechanism of DHS is not well understood, clinicians need to be mindful of the aetiology and risk factors in order to manage patients' pain and expectations and prevent further dentin exposure with subsequent sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At the beginning of the 20th Century, cervical cancer was the leading cause of death from cancer in women. A marked decline in cervical cancer has been observed since the 1960s, in parallel with the introduction of the Papanicolau (Pap) test as a cytological screening method. Today, Pap smear screening is still the most widely used tool for cervical cancer prevention. Testing for human papillomavirus (HPV) in cervical specimens or a combination of Pap and HPV testing are also now available. In this article we compare current guidelines for cervical cancer screening in Switzerland with those in other European countries. In view of the opportunities offered by HPV testing and, since 2008, HPV vaccination, current guidelines for cervical cancer screening should be updated. Both the choice of screening tests and general organization of cervical cancer screening should be reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND CONTEXT A new device, DensiProbe, has been developed to provide surgeons with intraoperative information about bone strength by measuring the peak breakaway torque. In cases of low bone quality, the treatment can be adapted to the patient's condition, for example, by improving screw-anchorage with augmentation techniques. PURPOSE The objective of this study was to investigate the feasibility of DensiProbe Spine in patients undergoing transpedicular fixation. STUDY DESIGN Prospective feasibility study on consecutive patients. PATIENT SAMPLE Fourteen women and 16 men were included in this study. OUTCOME MEASURES Local and general bone quality. METHODS These consecutive patients scheduled for transpedicular fixation were evaluated for bone mineral density (BMD), which was measured globally by dual-energy X-ray absorptiometry and locally via biopsies using quantitative microcomputed tomography. The breakaway torque force within the vertebral body was assessed intraoperatively via the transpedicular approach with the DensiProbe Spine. The results were correlated with the areal BMD at the lumbar spine and the local volumetric BMD (vBMD) and a subjective impression of bone strength. The feasibility of the method was evaluated, and the clinical and radiological performance was evaluated over a 1-year follow-up. This study was funded by an AO Spine research grant; DensiProbe was developed at the AO Research Institute Davos, Switzerland; the AO Foundation is owner of the intellectual property rights. RESULTS In 30 patients, 69 vertebral levels were examined. The breakaway torque consistently correlated with an experienced surgeon's quantified impression of resistance as well as with vBMD of the same vertebra. Beyond a marginal prolongation of surgery time, no adverse events related to the usage of the device were observed. CONCLUSIONS The intraoperative transpedicular measurement of the peak breakaway torque was technically feasible, safe, and reliably predictive of local vBMD during dorsal spinal instrumentations in a clinical setting. Larger studies are needed to define specific thresholds that indicate a need for the augmentation or instrumentation of additional levels.