Comparison of the biomechanical properties of a ventral cervical intervertebral anchored fusion device with locking plate fixation applied to cadaveric canine cervical spines
Data(s) |
07/09/2013
|
---|---|
Resumo |
OBJECTIVE: To evaluate fixation properties of a new intervertebral anchored fusion device and compare these with ventral locking plate fixation. STUDY DESIGN: In vitro biomechanical evaluation. ANIMALS: Cadaveric canine C4-C7 cervical spines (n = 9). METHODS: Cervical spines were nondestructively loaded with pure moments in a nonconstraining testing apparatus to induce flexion/extension while angular motion was measured. Range of motion (ROM) and neutral zone (NZ) were calculated for (1) intact specimens, (2) specimens after discectomy and fixation with a purpose-built intervertebral fusion cage with integrated ventral fixation, and (3) after removal of the device and fixation with a ventral locking plate. RESULTS: Both fixation techniques resulted in a decrease in ROM and NZ (P < .001) compared with the intact segments. There were no significant differences between the anchored spacer and locking plate fixation. CONCLUSION: An anchored spacer appears to provide similar biomechanical stability to that of locking plate fixation. |
Formato |
application/pdf |
Identificador |
http://boris.unibe.ch/40380/1/vsu12044.pdf Schöllhorn, Bernhard; Bürki, Alexander; Stahl, Christina; Howard, J.; Forterre, Franck (2013). Comparison of the biomechanical properties of a ventral cervical intervertebral anchored fusion device with locking plate fixation applied to cadaveric canine cervical spines. Veterinary surgery, 42(7), pp. 825-831. Wiley-Blackwell 10.1111/j.1532-950X.2013.12044.x <http://dx.doi.org/10.1111/j.1532-950X.2013.12044.x> doi:10.7892/boris.40380 info:doi:10.1111/j.1532-950X.2013.12044.x info:pmid:24033669 urn:issn:0161-3499 |
Idioma(s) |
eng |
Publicador |
Wiley-Blackwell |
Relação |
http://boris.unibe.ch/40380/ http://www.ncbi.nlm.nih.gov/pubmed/24033669 |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Schöllhorn, Bernhard; Bürki, Alexander; Stahl, Christina; Howard, J.; Forterre, Franck (2013). Comparison of the biomechanical properties of a ventral cervical intervertebral anchored fusion device with locking plate fixation applied to cadaveric canine cervical spines. Veterinary surgery, 42(7), pp. 825-831. Wiley-Blackwell 10.1111/j.1532-950X.2013.12044.x <http://dx.doi.org/10.1111/j.1532-950X.2013.12044.x> |
Palavras-Chave | #610 Medicine & health |
Tipo |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion PeerReviewed |