926 resultados para no conforming mesh


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work however presented try to make an analysis of the relation urban-agricultural in the context of the process of metropolization of Natal. On the basis of this approach searched to argue the estruturation of the Brazilian urban space and the relation with the agricultural one, evidencing an academic debate little contemplated, in view of that the space transformations guided by Brazilian industrialization had earned as endorsement a mere urban direction, fact that neglected factors more complex than they for the urban-agricultural relation in the context of the urbanization and, more recently, of the metropolization. Another important factor in the construction of the work was the contextualization of the urbanization of the Rio Grande do Norte, as well as of the metropolization of Natal, where if the significant presence of an agricultural reality made an analysis of the configuration metropolitan in the present time displaying that also remains and reproduces the metropolis, fact that conditions and justifies the treatment of the reality metropolitan for the bias of the urban-agricultural relation. The approach of this relation was directed for the agricultural nestings of the Region Metropolitan of Natal (RMN), understood as fragments agricultural in the context of the metropolis, in view of that a tenuous correspondence of these nestings with the metropolis in the direction of its integration was observed. As methodology one used bibliographical survey in periodic and books and collected secondary data-collecting next to the IBGE and to the INCRA and still were directed a field research where interviews next to the seated ones had been carried through. In this direction, one evidenced that the metropolization also absorbs and even though it reproduces the ruralidade that if verifies in the RMN finishing for mining the idea of an urban one that it excludes the agricultural one. In the case of the RMN, we have agricultural and the urban one exactly if conforming in one space that is metropolitan

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the 1980‟s, the Brazilian State has undergone a process of redemocratization, causing a profund change in the political and institutional organization of the country. That reorientation of the Brazilian federative structure had as normative framework the enactment of the federal Constitution of 1988, occuring after its enactment a considerable political opening under the cloak of new democratic arrangements of tax and fiscal decentralization, which generated a new federative order, especially with regard to municipalities. Such institutions contributed to the creation of several new municipalities, involving, directly, changes in the structure of national territory, driven by the political context. This case was notoriouns in the 1990s, increased in the country's municipal mesh and spread all over the states of the federation. The Paraíba State was integrated in this context, creating in this period, 52 new municipalities. In the perspective, it will seek to understand the purpose that sustained this process of fragmentation of Paraíba state territory. For this purpose was made use of several bibliographies, secondary data, documentary sources and research in locus of the municipalities of Casserengue and Riachão, located in the Paraíba‟s Curimataú Oriental microregion, which were selected as a focus for specific analysis of the event. It is understood, however, that the production of municipalities, includes several intentions through political appropriation of the territory, although, being permeated by the Institutional

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We placed spheres of synthetic hydroxyapatite (calcium chloride combined with sodium phosphate) in the eviscerated or enucleated orbital cavity of rats in order to evaluate the biocompatibility of this material with the orbital cavity. The study was conducted on 50 albino rats, 25 of which were submitted to enucleation and 25 to evisceration of one eye. The animals were sacrificed 7, 15, 21, 30 and 60 days after surgery and the orbital content was submitted to histopathological examination. A reaction of the young granulation tissue type was observed first. The hydroxyapatite was gradually surrounded by a granulomatous macrophage inflammatory response and covered with dense connective tissue that formed a sort of mesh septating and supporting progressively smaller blocks of the substance. The same type of reaction was observed in the enucleated and eviscerated cavities. We conclude that synthetic hydroxyapatite is an inert nonallergenic material which is appropriate for volume replacement in the anophthalmic cavity

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to assess the influence of cusp inclination on stress distribution in implant-supported prostheses by 3D finite element method.Materials and Methods: Three-dimensional models were created to simulate a mandibular bone section with an implant (3.75 mm diameter x 10 mm length) and crown by means of a 3D scanner and 3D CAD software. A screw-retained single crown was simulated using three cusp inclinations (10 degrees, 20 degrees, 30 degrees). The 3D models (model 10d, model 20d, and model 30d) were transferred to the finite element program NeiNastran 9.0 to generate a mesh and perform the stress analysis. An oblique load of 200 N was applied on the internal vestibular face of the metal ceramic crown.Results: The results were visualized by means of von Mises stress maps. Maximum stress concentration was located at the point of application. The implant showed higher stress values in model 30d (160.68 MPa). Cortical bone showed higher stress values in model 10d (28.23 MPa).Conclusion: Stresses on the implant and implant/abutment interface increased with increasing cusp inclination, and stresses on the cortical bone decreased with increasing cusp inclination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of the platform-switching technique on stress distribution in implant, abutment, and pen-implant tissues, through a 3-dimensional finite element study. Three 3-dimensional mandibular models were fabricated using the Solid Works 2006 and InVesalius software. Each model was composed of a bone block with one implant 10 mm long and of different diameters (3.75 and 5.00 mm). The UCLA abutments also ranged in diameter from 5.00 mm to 4.1 mm. After obtaining the geometries, the models were transferred to the software FEMAP 10.0 for pre- and postprocessing of finite elements to generate the mesh, loading, and boundary conditions. A total load of 200 N was applied in axial (0 degrees), oblique (45 degrees), and lateral (90) directions. The models were solved by the software NeiNastran 9.0 and transferred to the software FEMAP 10.0 to obtain the results that were visualized through von Mises and maximum principal stress maps. Model A (implants with 3.75 mm/abutment with 4.1 mm) exhibited the highest area of stress concentration with all loadings (axial, oblique, and lateral) for the implant and the abutment. All models presented the stress areas at the abutment level and at the implant/abutment interface. Models B (implant with 5.0 mm/abutment with 5.0 mm) and C (implant with 5.0 mm/abutment with 4.1 mm) presented minor areas of stress concentration and similar distribution pattern. For the cortical bone, low stress concentration was observed in the pen-implant region for models B and C in comparison to model A. The trabecular bone exhibited low stress that was well distributed in models B and C. Model A presented the highest stress concentration. Model B exhibited better stress distribution. There was no significant difference between the large-diameter implants (models B and C).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objectives of this study were, through a literature review, to point the differences between orbital implants and their advantages and disadvantages, to evaluate prosthesis motility after orbital implants are inserted, and to point the implant wrapping current risks. Sixty-seven articles were reviewed. Enucleation implants can be autoplastics or alloplastics and porous (including natural and synthetic hydroxyapatite [HA]) or nonporous (silicone). Hydroxyapatite is the most related in the literature, but it has disadvantages, too, that is, all orbital implants must be wrapped. Exposure of the porous orbital implant can be repaired using different materials, which include homologous tissue, as well as autogenous graft, xenograft, and synthetic material mesh. The most used materials are HA and porous polyethylene orbital implant. The HA implant is expensive and possibly subject corals to damage, different from porous polyethylene orbital implants. Porous implants show the best prosthesis motility and a minimum rate of implants extrusion. Implant wraps can facilitate smoother entry of the implant into the orbit and allow reattachment of extraocular muscles. They also serve as a barrier between the overlying soft tissue and the rough surface of the implant, protecting implants from exposure or erosion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statement of problem. Implant overdenture prostheses are prone to acrylic resin fracture because of space limitations around the implant overdenture components.Purpose. The purpose of this study was to evaluate the influence of E-glass fibers and acrylic resin thickness in resisting acrylic resin fracture around a simulated overdenture abutment.Material and methods. A model was developed to simulate the clinical situation of an implant overdenture abutment with varying acrylic resin thickness (1.5 or 3.0 mm) with or without E-glass fiber reinforcement. Forty-eight specimens with an underlying simulated abutment were divided into 4 groups (n=12): 1.5 mm acrylic resin without E-glass fibers identified as thin with no E-glass fiber mesh (TN-N); 1.5 mm acrylic resin with E-glass fibers identified as thin with E-glass fiber mesh (TN-F); 3.0 mm acrylic resin without E-glass fibers identified as thick without E-glass fiber mesh (TK-N); and 3.0 mm acrylic resin with E-glass fibers identified as thick with E-glass fiber mesh (TK-F). All specimens were submitted to a 3-point bending test and fracture loads (N) were analyzed with a 2-way ANOVA and Tukey's post hoc test (alpha=.05).Results. The results revealed significant differences in fracture load among the 4 groups, with significant effects from both thickness (P<.001) and inclusion of the mesh (P<.001). Results demonstrated no interaction between mesh and thickness (P=.690). The TN-N: 39 +/- 5 N; TN-F: 50 +/- 6.9 N; TK-N: 162 +/- 13 N; and TK-F: 193 +/- 21 N groups were all statistically different (P<.001).Conclusions. The fracture load of a processed, acrylic resin implant-supported overdenture can be significantly increased by the addition of E-glass fibers even when using thin acrylic resin sections. on a relative basis, the increase in fracture load was similar when adding E-glass fibers or increasing acrylic resin thickness. (J Prosthet Dent 2011;106:373-377)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study assessed masticatory efficiency and duration of the masticatory cycle in 14 asymptomatic patients with severe bone resorption. All patients had worn complete dentures for over 10 years. Recall visits were scheduled at 5 months and 1 year after receiving new dentures.Materials and Methods: Fourteen patients were evaluated in this study. The Research Diagnostic Criteria questionnaire and tests of the efficiency and duration of the masticatory cycle were performed with artificial food before, 5 months after, and 1 year after new dentures were delivered. Masticatory efficiency was assessed using a sieve system; artificial food was ground for 35 masticatory cycles and monitored by the operator.Results: Masticatory efficiency at 5 months was significantly improved for the 0.42-mm mesh. An improvement in masticatory efficiency and a reduction in mastication time were observed with the new dentures after 1 year.Conclusion: The results of this study indicated that 5 months did not allow enough time to demonstrate improved muscular capacity and ability after receiving new dentures. After 1 year, the duration of the masticatory cycle was reduced, and masticatory efficiency was significantly improved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: avaliar o Índice de Remanescente Adesivo (IRA) em dentes bovinos após a descolagem de braquetes com e sem tratamento na base. METODOLOGIA: foram utilizados três sistemas de colagem ortodôntica para os dois padrões de base. Os dentes bovinos foram divididos em seis grupos de 40, de acordo com a base do braquete e o sistema de colagem. Vinte e quatro horas após a colagem foram realizados os testes de compressão em uma máquina de ensaios. A avaliação do IRA foi realizada em um estereomicroscópio por três examinadores calibrados. Foi utilizado o teste não paramétrico de Kruskal-Wallis, seguido do método de Dunn, para fazer as comparações múltiplas entre todos os grupos. RESULTADOS E CONCLUSÕES: observou-se que o tratamento das bases dos braquetes com óxido de alumínio não foi determinante para o aumento da adesividade entre o braquete e o adesivo. O grupo em que se utilizou braquetes com tratamento na base e adesivo TXT (3M-Unitek) + Transbond Plus SEP (3M-Unitek) apresentou a maior parte das fraturas na interface dente-adesivo (escore 4).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Catch and selectivity parameters using gillnets were calculated for Schizodon nasutus in the Jurumirim reservoir on the Parana-panema River in southern Brazil. The simple gillnets used were made of monofilament nylon of 30 to 140 mm mesh size an of different heights. The relative abundance of the S. nasutus caught was analysed monthly and a positive relationship was found between catches per unit effort in number and biomass. The relative catches were more abundant for the nets of 40 and 50 mm, mesh size. Catches were characterized by clear temporal variations and a predominance of medium size fish throughout the study period. The selectivity curve of gillnets for S. nasutus in this ecosystem was obtained. The catch obtained was compared with the available catch for each mesh size, and the available catch for a certain length of fish was calculated starting from the theoretical selectivity curve. The 50 mm mesh size gillnet showed the best fit between real and available captures and was considered the most suitable, because a smaller mesh size resulted in a catch of predominantly immature specimens. It is expected that these results will contribute to improving management strategies for conservation of resources. Parameters such as the minimum catch length advisable or the mesh size permitted for a given species are indispensable for such decision-making.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this work was to examine the occurrence of brachyurans in soft bottom sublittoral habitats and their association with some environmental factors. The relative abundance of crabs in two depth strata (from 4.5 to 9 m and from 9 to 18 m) was quantified. Crabs were collected with an otter-trawl with 3.7 m of mouth opening and 12-mm mesh in the cod end. Monthly sampling, consisted of a single trawl in each stratum during a 1-yr period, were carried out. Fifteen brachyuran and six anomuran species were found, including Callinectes ornatus Ordway, 1863; Callinectes danae Smith, 1869; Hepatus pudibundus (Herbst, 1785); Libinia spinosa H. Milne-Edwards, 1834; Persephona punctata (Linnaeus, 1758), and P. mediterranea (Herbst, 1794), which were the most abundant and frequent in the area. The most abundant swimming crabs in both strata were C. ornatus and C, dan(re. Size differences in C. ornatus were observed between strata, suggesting a spatial separation of juveniles and adult crabs.