931 resultados para mercury abatement


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The crystal structures of two ammonium bromomercurates(II), (NH4)Hg5Br11 (1) and (NH4)(4)HgBr6 (2), were determined from single-crystal X-ray diffraction data: 1: monoclinic, C2/m (no. 12), a = 1231.3(3), b = 1517.4(3), c = 680.4(2) pm, beta = 118.78(2)degrees, Z = 2, R-1 = 0.0391 for I-0 > 2 sigma(I-0); 2: tetragonal, P4/mnc (no. 128), a = 925.6(1), c = 887.2(1) pm, Z = 2, R-1 = 0.0370 for I(0 >)2a(I-0). According to (NH4)Br[HgBr2](5) and (NH4)(4)Br-4[HgBr2] they both contain [Br-Hg-Br] molecules. Additional bromide ions are only loosely attached to the mercury atoms, however involved in (NH4)(+)-Br- bonding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[Hg(NH3)(2)][HgCl3](2) (1) is obtained by saturating an equimolar solution of HgCl2 and NH4Cl with Hg(NH2)Cl at 75 degreesC. 1 crystallizes in the orthorhombic space group Pmna with a = 591.9(1) pm, b = 800.3(1) pm, c = 1243.3(4) pm, Z = 2. The structure consists of linear cations [Hg(NH3)(2)](2+) and T-shaped anions [HgCl3](-). The coordination sphere of mercury is

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ammonium chloride/mercuric chloride mixtures (molar ratio 2: 1) react at 350degreesC with Monel (Cu68Ni32) to yield (NH4)NiCl3 and mercury and copper amalgam, respectively. With larger amounts of (NH4)Cl in the reaction mixture, dark green (NH4)(2)(NH3)(x)[Ni(NH3)(2)Cl-4] (x approximate to 0.77) (1) is also formed as a main product. Light blue crystals of the mixed-valent copper(I,II) chloride (NH4)(5)Cl-5[CuCl2][CuCl4] (2) were obtained as a minor byproduct from a 4:1 reaction mixture. The crystal structures were determined from single crystal X-ray data; (1): tetragonal, I4/mmm, a = 770.9(1), e = 794.2(2) pm, 190 reflections, R-1 = 0.0263; (2): tetragonal, I4/mcm, a = 874.8(1), c = 2329.2(3) pm, 451 reflections, R-1 = 0.0736. In (1) Ni2+ resides in trans-[Ni(NH3)(2)Cl-4](2-) octahedra, and in (2) copper(l) is linearly two-coordinated in ECUC121- and copper(II) resides in a flattened tetrahedron [CuCl4](2-) with a tetrahedricity of 89%. (C) 2001 Elsevier Science.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monolithic catalysts are widely used as structured catalysts, especially in the abatement of pollutants. Probing what happens inside these monoliths during operation is, therefore, vital for modelling and prediction of the catalyst behavior. SpaciMS is a spatially resolved capillary-inlet mass spectroscopy system allowing for the generation of spatially resolved maps of the reactions within monoliths. In this study SpaciMS results combined with 3D CFD modelling demonstrate that SpaciMS is a highly sensitive and minimally invasive technique that can provide reaction maps as well as catalytic temporal behavior. Herein we illustrate this by examining kinetic oscillations during a CO oxidation reaction over a Pt/Rh on alumina catalyst supported on a cordierite monolith. These oscillations were only observed within the monolith by SpaciMS between 30 and 90% CO conversion. Equivalent experiments performed in a plug-flow reactor using this catalyst in a crushed form over a similar range of reaction conditions did not display any oscillations demonstrating the importance of intra monolith analysis. This work demonstrates that the SpaciMS offers an accurate and comprehensive picture of structured catalysts under operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objectives of this study were to develop a three-dimensional acellular cartilage matrix (ACM) and investigate its possibility for use as a scaffold in cartilage tissue engineering. Bovine articular cartilage was decellularized sequentially with trypsin, nuclease solution, hypotonic buffer, and Triton x 100 solution; molded with freeze-drying process; and cross-linked by ultraviolet irradiation. Histological and biochemical analysis showed that the ACM was devoid of cells and still maintained the collagen and glycosaminoglycan components of cartilage. Scanning electronic microscopy and mercury intrusion porosimetry showed that the ACM had a sponge-like structure of high porosity. The ACM scaffold had good biocompatibility with cultured rabbit bone marrow mesenchymal stem cells with no indication of cytotoxicity both in contact and in extraction assays. The cartilage defects repair in rabbit knees with the mesenchymal stem cell-ACM constructs had a significant improvement of histological scores when compared to the control groups at 6 and 12 weeks. In summary, the ACM possessed the characteristics that afford it as a potential scaffold for cartilage tissue engineering.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

User induced errors are common when women repetitively employ conventional probe type thermometers to chart their basal body temperatures in an effort to indicate ovulation. An alternative technique employing a two-part telemetric thermometer is proposed, with low-power, SAWR-controlled UHF radio as the transmission medium. Worn overnight in the vagina, the 1 mu W erp telemetry transmitter sends pulse modulated data continuously to a microcontroller in a nearby receiver; a real time clock enables programmable sampling and storage of the subject's temperature to 0.1 degrees C resolution. Initial clinical results indicate an enhanced performance compared to oral and axillary temperature trends taken by a mercury-in-glass thermometer. Polar plots of both the isolated and body-worn telemetry transmitte are presented; body indced attenuations of up to 30 dB were measured.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Macroporosity(>100µm) in bone void fillers is a known prerequisite for tissue regeneration, but recent literature has highlighted the added benefit of microporosity(0.5 - 10µm). The aim of this study was to compare the in vitro performances of a novel interconnective microporous hydroxyapatite (HA) derived from red algae to four clinically available macroporous calcium phosphate (CaP) bone void fillers. The use of algae as a starting material for this novel void filler overcomes the issue of sustainability, which overshadows continued use of scleractinian coral in the production of some commercially available materials, namely Pro-OsteonTM and Bio-Coral®. This study investigated the physicochemical properties of each bone voidfiller material using x-ray diffraction, fourier transform infrared spectroscopy, inductive coupled plasma, and nitrogen gas absorption and mercury porosimetry. Biochemical analysis, XTT, picogreen and alkaline phosphatase assays were used to evaluate the biological performances of the five materials. Results showed that algal HA is non-toxic to human foetal osteoblast (hFOB) cells and supports cell proliferation and differentiation. The preliminary in vitro testing of microporous algal-HA suggests that it is comparable to the four clinically approved macroporous bone void fillers tested. The results demonstrate that microporous algal HA has good potential for use in vivo and in new tissue engineered strategies for hard tissue repair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nanocrystalline TiO2 deposited on conducting glass plates is shown to be an excellent material for preconcentration of silver and mercury, via photochemical reaction, prior to their detection by anodic stripping voltammetry (ASV). During the first stage of growth in the photoreduction of silver or mercury, 3D nuclei are formed on the TiO2 film. As the deposition proceeds micrometer size agglomerates grow on the surface. The conical morphology of the silver nuclei grown on a (110) rutile single crystal in the initial stages of growth suggests that there is a preferential deposition of silver at the centre of the growing nuclei. When the nuclei size reach a critical value (ca. 400 nm diameter, 40 nm height) the morphology changes to a globular shape without any preferential site for deposition on the surface of the silver nucleus. It was observed that micromolar concentrations of silver or mercury can be detected by anodic stripping voltammetry and relatively large amounts of these metals (micrometer scale nuclei) can be loaded on the nanocrystalline TiO2 film surface. The latter opens the possibility of analytical applications of nanocrystalline TiO2 electrodes for the selective detection of silver or mercury via photochemical anodic stripping voltammetry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A rapid and sensitive biosensor immunoassay was developed for determination of ivermectin residues in bovine milk. A detection limit of 16.2 ng/mL was achieved. A Biacore optical biosensor based on surface plasmon resonance was used, and a range of extraction techniques was investigated. In the final assay procedure, ivermectin was extracted with acetonitrile followed by C-8 solid-phase extraction cleanup. It was proven experimentally that 2 methods of milk storage, freezing or addition of mercury-containing compounds as preservatives, could be used without considerable change in detected concentrations (samples were fortified with ivermectin after storage). The average values for milk samples spiked at 100 and 50 ng/mL concentrations were 102.6 and 51.5 ng/mL, respectively. Extraction and analysis of 20 milk samples were performed within a single working day.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trace elements have been cited as both inhibitory and causative agents of cancer but importantly exposure to them is potentially modifiable. Our study aimed to examine toenail trace element status and risk of Barrett's oesophagus (BO) and oesophageal adenocarcinoma (OAC). Toenail clippings from each hallux were obtained from 638 participants of the FINBAR (Factors Influencing the Barrett's Adenocarcinoma Relationship) study comprising 221 healthy controls, 98 reflux oesophagitis, 182 BO and 137 OAC cases. The concentrations of eight toenail trace elements were determined using instrumental neutron activation analysis. Using multivariable adjusted logistic regression analysis, odds ratios (OR) and 95% confidence intervals (CIs) were calculated within tertiles of trace element concentrations. A twofold increased risk of BO was observed, but not OAC, among individuals in the highest tertile of toenail zinc status OR 2.21 (95% CI, 1.11-4.40). A higher toenail selenium status was not associated with risk of OAC OR 0.94 (95% CI, 0.44-2.04) or BO OR 0.89 (95% CI, 0.37-2.12). A borderline significant increased risk of BO was detected with a higher toenail cobalt concentration, OR 1.97 (95% CI, 1.01-3.85). No association was found between toenail levels of chromium, cerium, mercury and OAC or BO risk. This is the first case-control study to investigate a variety of trace elements in relation to OAC and BO risk. Despite antioxidant and proapoptotic properties, no associations were found with selenium. Higher concentrations of toenail zinc and cobalt were associated with an increased BO risk, but not OAC. These findings need confirmation in prospective analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The commonly used British Standard constant head triaxial permeability (BS) test, for permeability testing of fine grained soils, is known to have a relatively long test duration. Consequently, a reduction in the required time for permeability test provides potential cost savings, to the construction industry (specifically, for use during Construction Quality Control (CQA) of landfill mineral liners). The purpose of this article is to investigate and evaluate alternative short duration testing methods for the measurement of the permeability of fine grained soils.

As part of the investigation the feasibility of an existing method of short duration permeability test, known as the Accelerated Permeability (AP) test was assessed and compared with permeability measured using British Standard method (BS) and Ramp Accelerated Permeability (RAP). Four different fine grained materials, of a variety of physical properties were compacted at various moisture contents to produced analogous samples for testing using three the three different methodologies. Fabric analysis was carried out on specimens derived from post-test samples using Mercury Intrusion Porosimetry (MIP) and Scanning Electron Microscope (SEM) to assess the effects of testing methodology on soil structure. Results showed that AP testing in general under predicts permeability values derived from the BS test due to large changes in structure of the soil caused by AP test methodology, which is also validated using MIP and SEM observations. RAP testing, in general provides an improvement to the AP test but still under-predicts permeability values. The potential savings in test duration are shown to be relatively minimal for both the AP and RAP tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present invention relates to a process for the removal of mercury from a mercury- containing hydrocarbon fluid feed using specifically selected ionic liquids comprising, contacting the mercury-containing hydrocarbon fluid feed with an ionic liquid having the formula[Cat+][M+][X-] and separating from the ionic liquid a hydrocarbon fluid product having a reduced mercury content compared to the mercury-containing fluid feed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Structural and functional information encoded in DNA combined with unique properties of nanomaterials could be of use for the construction of novel biocomputational circuits and intelligent biomedical nanodevices. However, at present their practical applications are still limited by either low reproducibility of fabrication, modest sensitivity, or complicated handling procedures. Here, we demonstrate the construction of label-free and switchable molecular logic gates that use specific conformation modulation of a guanine- and thymine- rich DNA, while the optical readout is enabled by the tunable alphabetical metamaterials, which serve as a substrate for surface enhanced Raman spectroscopy (MetaSERS). By computational and experimental investigations, we present a comprehensive solution to tailor the plasmonic responses of MetaSERS with respect to the metamaterial geometry, excitation energy, and polarization. Our tunable MetaSERS-based DNA logic is simple to operate, highly reproducible, and can be stimulated by ultra-low concentration of the external inputs, enabling an extremely sensitive detection of mercury ions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The crystal structure of (Me3PhN)[HgCl3] contains [(CH3)(3)(C6H5)N](+) cations and chains of distorted vertex-sharing [HgCl4](2-) tetrahedra running parallel to [100]. The tetrahedra around mercury(II) are distorted, exhibiting a [2+2] coordination. Apart from one of the Cl atoms, which is located on a twofold rotation axis, and a pair of symmetry-related methyl C atoms, which are located in general positions, all non H-atoms lie on mirror planes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The structure of (Et4N)(2)[Hg3Br8] contains isolated dinuclear [Hg2Br6](2-) anions and neutral HgBr2 molecules. Charge balance is achieved by ordered [Et4N](+) cations. The formula may therefore be written as (Et4N)(2)[Hg2Br6][HgBr2]. The N atoms of the (Et4N)(+) ions lie on a (4) over bar axis along [001] and, whereas one of the mercury(II) ions is placed on a mirror plane perpendicular to the c axis, the second one is located on a special position of site symmetry 2/m.