880 resultados para Tunable


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to the lack of optical random access memory, optical fiber delay line (FDL) is currently the only way to implement optical buffering. Feed-forward and feedback are two kinds of FDL structures in optical buffering. Both have advantages and disadvantages. In this paper, we propose a more effective hybrid FDL architecture that combines the merits of both schemes. The core of this switch is the arrayed waveguide grating (AWG) and the tunable wavelength converter (TWC). It requires smaller optical device sizes and fewer wavelengths and has less noise than feedback architecture. At the same time, it can facilitate preemptive priority routing which feed-forward architecture cannot support. Our numerical results show that the new switch architecture significantly reduces packet loss probability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By performing density functional theory calculations we show that it is possible to make the electronic bandgap in bilayer graphene supported on hexagonal boron nitride (h-BN) substrates tunable. We also show that, under applied electric fields, it is possible to insert states from h-BN into the bandgap, which generate a conduction channel through the substrate making the system metallic. In addition, we verify that the breakdown voltage strongly depends on the number of h-BN layers. We also show that both the breakdown voltage and the bandgap tuning are independent of the h-BN stacking order.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we report studies of the photoluminescence emission in samples based on Si/SiOx films deposited by the Pulsed Electron Beam Ablation (PEBA) technique. The samples were prepared at room temperature using targets with different Si/SiO2 concentrations. The samples were characterized using X-ray Absorption Edge Spectroscopy (XANES) at the Si-K edge, Raman spectroscopy, Photoluminescence (PL) and X-ray Photoelectron Spectroscopy (XPS). The concentration of a-Si and nc-Si in the film was dependent on the silicon concentration in the target. It was also observed that the PL is strongly dependent on the structural amorphous/crystalline arrangement. Crown Copyright (C) 2011 Published by Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper investigates the effect of solvent-induced conformational changes of poly(3,6-phenanthrene) on their two-photon absorption (2PA). Such effect was studied employing the wavelength-tunable femtosecond Z-scan technique and modeled using the sum-over-essential states approach. We observed a strong reduction of the 2PA cross-section when the sample was prepared in hexane (poor solvent) in comparison to chloroform (good solvent), which is related to the conformation adopted by the polymer in each case. In chloroform it adopts a random coil conformation, as opposed to the one-handed helix conformation in hexane. Our results pointed out that the coil to helix conformation change decreases the degree of molecular planarity of the polymer pi-conjugated backbone, which is primarily responsible for their optical nonlinearity, contributing to diminishing the effective transition dipole moments and, consequently, the 2PA cross-section. Moreover, by studying the nonlinear response with different light polarization, we showed that, although the solvent-induced conformational change does not alter the molecular symmetry of the polymer, it modifies considerably the direction of the transition dipole moments between the excited states.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose a slow-wave MEMS phase shifter that can be fabricated using the CMOS back-end and an additional maskless post-process etch. The tunable phase shifter concept is formed by a conventional slow-wave transmission line. The metallic ribbons that form the patterned floating shield of this type of structure are released to allow motion when a control voltage is applied, which changes the characteristic impedance and the phase velocity. For this device a quality factor greater than 40 can be maintained, resulting in a figure of merit on the order of 0.7 dB/360 degrees and a total area smaller than 0.14 mm(2) for a 60-GHz working frequency. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fabrication of microstructures containing active compounds, such as fluorescent dyes and nanoparticles have been exploited in the last few years, aiming at applications from photonics to biology. Here we fabricate, using two-photon polymerization, microstructures containing the fluorescent dyes Stilbene 420, Disodium Fluorescein and Rhodamine B. The produced microstructures, containing dyes at specific sites, present good structural integrity and a broad fluorescence spectrum, from about 350 nm until 700 nm. Such spectrum can be tuned by using different excitation wavelengths and selecting the excitation position in the microstructure. These results are interesting for designing multi-doped structures, presenting tunable and broad fluorescence spectrum. (C)2012 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiation dose assessment is essential for several medical treatments and diagnostic procedures. In this context, nanotechnology has been used in the development of improved radiation sensors, with higher sensitivity as well as smaller sizes and energy dependence. This paper deals with the synthesis and characterization of gold/alanine nanocomposites with varying mass percentage of gold, for application as radiation sensors. Alanine is an excellent stabilizing agent for gold nanoparticles because the size of the nanoparticles does not augment with increasing mass percentage of gold, as evidenced by UV-vis spectroscopy, dynamic light scattering, and transmission electron microscopy. X-ray diffraction patterns suggest that the alanine crystalline orientation undergoes alterations upon the addition of gold nanoparticles. Fourier transform infrared spectroscopy indicates that there is interaction between the gold nanoparticles and the amine group of the alanine molecules, which may be the reason for the enhanced stability of the nanocomposite. The application of the nanocomposites as radiation detectors was evaluated by the electron spin resonance technique. The sensitivity is improved almost 3 times in the case of the nanocomposite containing 3% (w/w) gold, so it can be easily tuned by changing the amount of gold nanoparticles in the nanocomposites, without the size of the nanoparticles influencing the radiation absorption. In conclusion, the featured properties, such as homogeneity, nanoparticle size stability, and enhanced sensitivity, make these nanocomposites potential candidates for the construction of small-sized radiation sensors with tunable sensitivity for application in several medical procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is currently a strong interest in mirrorless lasing systems(1), in which the electromagnetic feedback is provided either by disorder (multiple scattering in the gain medium) or by order (multiple Bragg reflection). These mechanisms correspond, respectively, to random lasers(2) and photonic crystal lasers(3). The crossover regime between order and disorder, or correlated disorder, has also been investigated with some success(4-6). Here, we report one-dimensional photonic-crystal lasing (that is, distributed feedback lasing(7,8)) with a cold atom cloud that simultaneously provides both gain and feedback. The atoms are trapped in a one-dimensional lattice, producing a density modulation that creates a strong Bragg reflection with a small angle of incidence. Pumping the atoms with auxiliary beams induces four-wave mixing, which provides parametric gain. The combination of both ingredients generates a mirrorless parametric oscillation with a conical output emission, the apex angle of which is tunable with the lattice periodicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new multi-energy CT for small animals is being developed at the Physics Department of the University of Bologna, Italy. The system makes use of a set of quasi-monochromatic X-ray beams, with energy tunable in a range from 26 KeV to 72 KeV. These beams are produced by Bragg diffraction on a Highly Oriented Pyrolytic Graphite crystal. With quasi-monochromatic sources it is possible to perform multi-energy investigation in a more effective way, as compared with conventional X-ray tubes. Multi-energy techniques allow extracting physical information from the materials, such as effective atomic number, mass-thickness, density, that can be used to distinguish and quantitatively characterize the irradiated tissues. The aim of the system is the investigation and the development of new pre-clinic methods for the early detection of the tumors in small animals. An innovative technique, the Triple-Energy Radiography with Contrast Medium (TER), has been successfully implemented on our system. TER consist in combining a set of three quasi-monochromatic images of an object, in order to obtain a corresponding set of three single-tissue images, which are the mass-thickness map of three reference materials. TER can be applied to the quantitative mass-thickness-map reconstruction of a contrast medium, because it is able to remove completely the signal due to other tissues (i.e. the structural background noise). The technique is very sensitive to the contrast medium and is insensitive to the superposition of different materials. The method is a good candidate to the early detection of the tumor angiogenesis in mice. In this work we describe the tomographic system, with a particular focus on the quasi-monochromatic source. Moreover the TER method is presented with some preliminary results about small animal imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The digital electronic market development is founded on the continuous reduction of the transistors size, to reduce area, power, cost and increase the computational performance of integrated circuits. This trend, known as technology scaling, is approaching the nanometer size. The lithographic process in the manufacturing stage is increasing its uncertainty with the scaling down of the transistors size, resulting in a larger parameter variation in future technology generations. Furthermore, the exponential relationship between the leakage current and the threshold voltage, is limiting the threshold and supply voltages scaling, increasing the power density and creating local thermal issues, such as hot spots, thermal runaway and thermal cycles. In addiction, the introduction of new materials and the smaller devices dimension are reducing transistors robustness, that combined with high temperature and frequently thermal cycles, are speeding up wear out processes. Those effects are no longer addressable only at the process level. Consequently the deep sub-micron devices will require solutions which will imply several design levels, as system and logic, and new approaches called Design For Manufacturability (DFM) and Design For Reliability. The purpose of the above approaches is to bring in the early design stages the awareness of the device reliability and manufacturability, in order to introduce logic and system able to cope with the yield and reliability loss. The ITRS roadmap suggests the following research steps to integrate the design for manufacturability and reliability in the standard CAD automated design flow: i) The implementation of new analysis algorithms able to predict the system thermal behavior with the impact to the power and speed performances. ii) High level wear out models able to predict the mean time to failure of the system (MTTF). iii) Statistical performance analysis able to predict the impact of the process variation, both random and systematic. The new analysis tools have to be developed beside new logic and system strategies to cope with the future challenges, as for instance: i) Thermal management strategy that increase the reliability and life time of the devices acting to some tunable parameter,such as supply voltage or body bias. ii) Error detection logic able to interact with compensation techniques as Adaptive Supply Voltage ASV, Adaptive Body Bias ABB and error recovering, in order to increase yield and reliability. iii) architectures that are fundamentally resistant to variability, including locally asynchronous designs, redundancy, and error correcting signal encodings (ECC). The literature already features works addressing the prediction of the MTTF, papers focusing on thermal management in the general purpose chip, and publications on statistical performance analysis. In my Phd research activity, I investigated the need for thermal management in future embedded low-power Network On Chip (NoC) devices.I developed a thermal analysis library, that has been integrated in a NoC cycle accurate simulator and in a FPGA based NoC simulator. The results have shown that an accurate layout distribution can avoid the onset of hot-spot in a NoC chip. Furthermore the application of thermal management can reduce temperature and number of thermal cycles, increasing the systemreliability. Therefore the thesis advocates the need to integrate a thermal analysis in the first design stages for embedded NoC design. Later on, I focused my research in the development of statistical process variation analysis tool that is able to address both random and systematic variations. The tool was used to analyze the impact of self-timed asynchronous logic stages in an embedded microprocessor. As results we confirmed the capability of self-timed logic to increase the manufacturability and reliability. Furthermore we used the tool to investigate the suitability of low-swing techniques in the NoC system communication under process variations. In this case We discovered the superior robustness to systematic process variation of low-swing links, which shows a good response to compensation technique as ASV and ABB. Hence low-swing is a good alternative to the standard CMOS communication for power, speed, reliability and manufacturability. In summary my work proves the advantage of integrating a statistical process variation analysis tool in the first stages of the design flow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ZusammenfassungIm Rahmen der EU-Projekte POLSTAR (Polar StratosphericAerosol Experiment) und STREAM (Stratosphere TroposphereExperiment by Airborne Measurements) wurden flugzeuggetragene Spurengasmessungen in verschiedenen geografischen Breiten durchgeführt. Zwei Messkampagnen fanden im Januar (POLSTAR 97) und März (STREAM 97) 1997 über Kiruna (Schweden, 67°N, 20°O) statt, eine Kampagne wurde im Juli 1998 von Timmins (Kanada, 47°N, 81°W) aus durchgeführt (STREAM 98).CO und N2O wurden mittels TDLAS (Tunable Diode Laser Absorption Spectroscopy) nachgewiesen, CO2 wurde mit einem modifizierten kommerziellen Messgerät breitbandig gemessen. Zur Untersuchung von Mischungsvorgängen in der Tropopausenregion wurden Korrelationenzwischen CO, O3, N2O, CO2 und NOy herangezogen.Dabei konnte festgestellt werden, dass im Winter in der untersten Stratosphäre Mischung mit troposphärischen Luftmassen durch isentropen Transport im Bereich der Polarfront bis zu potentiellen Temperaturen von Theta=335K auftritt. Im Sommer lässt sich Mischung mit troposphärischen Luftmassen bis mindestens Theta=360K nachweisen, die effektiver als im Winter abläuft.Exemplarisch kann an einem Flug gezeigt werden, dassbis Theta=349K die Ausbildung der Mischungsschicht durchLuftmassenaustausch an der Polarfront verursacht wird, während oberhalb von Theta=349K Signaturen subtropischertroposphärischer Luftmassen gefunden werden.Der stratosphärische Hintergrund wird mitbestimmt durch photochemisch gealterte Luftmassen, die ihren Ursprung höchstwahrscheinlich in der Vortexregion des vorangegangenen Winters haben.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ZusammenfassungDie Resonanzionisationsmassenspektrometrie (RIMS) verbindet hohe Elementselektivität mit guter Nachweiseffizienz. Aufgrund dieser Eigenschaften ist die Methode für Ultraspurenanalyse und Untersuchungen an seltenen oder schwer handhabbaren Elementen gut geeignet. Für RIMS werden neutrale Atome mit monochromatischem Laserlicht ein- oder mehrfach resonant auf energetisch hoch liegende Niveaus angeregt und anschließend durch einen weiteren Laserstrahl oder durch ein elektrisches Feld ionisiert. Die Photoionen werden in einem Massenspektrometer massenselektiv registriert.Ein Beispiel für die Anwendung von RIMS ist die präzise Bestimmung der Ionisationsenergie als fundamentale physikalisch-chemische Eigenschaft eines bestimmten Elements; insbesondere bei den Actinoiden ist die Kenntnis der Ionisationsenergie von Interesse, da es dort bis zur Anwendung der laser-massenspektroskopischer Methode nur wenige experimentelle Daten gab. Die Bestimmung der Ionisationsenergie erfolgt durch die Methode der Photoionisation im elektrischen Feld gemäß dem klassischen Sattelpunktsmodell. Im Experiment werden neutrale Atome in einem Atomstrahl mittels Laserlicht zunächst resonant angeregt. Die angeregten Atome befinden sich in einem äußeren, statischen elektrischen Feld und werden durch einen weiteren Laserstrahl, dessen Wellenlänge durchgestimmt wird, ionisiert. Das Überschreiten der Laserschwelle macht sich durch einen starken Anstieg im Ionensignal bemerkbar. Man führt diese Messung bei verschiedenen elektrischen Feldstärken durch und erhält bei Auftragen der Ionisationsschwellen gegen die Wurzel der elektrischen Feldstärke durch Extrapolation auf die Feldstärke Null die Ionisationsenergie.Im Rahmen dieser Arbeit wurde die Ionisationsenergie von Actinium erstmalig zu 43398(3) cm-1 º 5,3807(4) eV experimentell bestimmt. Dazu wurden Actiniumatome zunächst einstufig resonant mit einem Laser mit einer Wellenlänge von 388,67 nm auf einen Zustand bei 25729,03 cm-1 angeregt und anschließend mit Laserlicht mit einer Wellenlänge von ca. 568 nm ionisiert. Damit sind die Ionisationsenergien aller Actinoiden bis einschließlich Einsteinium mit Ausnahme von Protactinium bekannt. Als Atomstrahlquelle wird ein spezielles 'Sandwichfilament' benutzt, bei dem das Actinoid als Hydroxid auf eine Tantalfolie aufgebracht und mit einer reduzierenden Deckschicht überzogen wird. Das Actinoid dampft bei Heizen dieser Anordnung atomar ab. Bei den schwereren Actinoiden wurde Titan als Deckschicht verwendet. Um einen Actiniumatomstrahl zu erzeugen, wurde aufgrund der hohen Abdampftemperaturen statt Titan erstmals Zirkonium eingesetzt. Bei Protactinium wurde Thorium, welches noch stärkere Reduktionseigenschaften aufweist, als Deckmaterial eingesetzt. Trotzdem gelang es mit der 'Sandwichtechnik' nicht, einen Protactiniumatomstrahl zu erzeugen. In der Flugzeitapparatur wurde lediglich ein Protactinium-monoxidionensignal detektiert. Um ein erst seit kurzem verfügbares Fest-körperlasersystem zu explorieren, wurden zusätzlich noch die bekannten Ionisations-ener-gien von Gadolinium und Plutonium erneut bestimmt. Die gemessenen Werte stimmen mit Literaturdaten gut überein.Ferner wurde noch ein bestehender Trennungsgang für Plutonium aus Umweltproben auf die Matrices Meerwasser und Hausstaub angepasst und für die Bestimmung von Plutonium und dessen Isotopenzusammensetzung in verschiedenen Probenreihen mittels RIMS eingesetzt. Der modifizierte Trennungsgang ermöglicht das schnelle Aufarbeiten von großen Probenmengen für Reihenuntersuchungen von Plutoniumkontaminationen. Die ermittelten Gehalten an 239Pu lagen zwischen 8,2*107 Atome pro 10 l Meerwasserprobe und 1,7*109Atome pro Gramm Staubprobe.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dramatic impact that vascular diseases have on human life quality and expectancy nowadays is the reason why both medical and scientific communities put great effort in discovering new and effective ways to fight vascular pathologies. Among the many different treatments, endovascular surgery is a minimally-invasive technique that makes use of X-ray fluoroscopy to obtain real-time images of the patient during interventions. In this context radiopaque biomaterials, i.e. materials able to absorb X-ray radiation, play a fundamental role as they are employed both to enhance visibility of devices during interventions and to protect medical staff and patients from X-ray radiations. Organic-inorganic hybrids are materials that combine characteristics of organic polymers with those of inorganic metal oxides. These materials can be synthesized via the sol-gel process and can be easily applied as thin coatings on different kinds of substrates. Good radiopacity of organic-inorganic hybrids has been recently reported suggesting that these materials might find applications in medical fields where X-ray absorption and visibility is required. The present PhD thesis aimed at developing and characterizing new radiopaque organic-inorganic hybrid materials that can find application in the vascular surgery field as coatings for the improvement of medical devices traceability as well as for the production of X-ray shielding objects and garments. Novel organic-inorganic hybrids based on different polyesters (poly-lactic acid and poly-ε-caprolactone) and polycarbonate (poly-trimethylene carbonate) as the polymeric phase and on titanium oxide as the inorganic phase were synthesized. Study of the phase interactions in these materials allowed to demonstrate that Class II hybrids (where covalent bonds exists between the two phases) can be obtained starting from any kind of polyester or polycarbonate, without the need of polymer pre-functionalization, thanks to the occurrence of transesterification reactions operated by inorganic molecules on ester and carbonate moieties. Polyester based hybrids were successfully coated via dip coating on different kinds of textiles. Coated textiles showed improved radiopacity with respect to the plain fabric while remaining soft to the touch. The hybrid was able to coat single fibers of the yarn rather than coating the yarn as a whole. Openings between yarns were maintained and therefore fabric breathability was preserved. Such coatings are promising for the production of light-weight garments for X-ray protection of medical staff during interventional fluoroscopy, which will help preventing pathologies that stem from chronic X-ray exposure. A means to increase the protection capacity of hybrid-coated fabrics was also investigated and implemented in this thesis. By synthesizing the hybrid in the presence of a suspension of radiopaque tantalum nanoparticles, PDMS-titania hybrid materials with tunable radiopacity were developed and were successfully applied as coatings. A solution for enhancing medical device radiopacity was also successfully investigated. High metal radiopacity was associated with good mechanical and protective properties of organic-inorganic hybrids in the form of a double-layer coating. Tantalum was employed as the constituent of the first layer deposited on sample substrates by means of a sputtering technique. The second layer was composed of a hybrid whose constituents are well-known biocompatible organic and inorganic components, such as the two polymers PCL and PDMS, and titanium oxide, respectively. The metallic layer conferred to the substrate good X-ray visibility. A correlation between radiopacity and coating thickness derived during this study allows to tailor radiopacity simply by controlling the metal layer sputtering deposition time. The applied metal deposition technique also permits easy shaping of the radiopaque layer, allowing production of radiopaque markers for medical devices that can be unambiguously identified by surgeons during implantation and in subsequent radiological investigations. Synthesized PCL-titania and PDMS-titania hybrids strongly adhered to substrates and show good biocompatibility as highlighted by cytotoxicity tests. The PDMS-titania hybrid coating was also characterized by high flexibility that allows it to stand large substrate deformations without detaching nor cracking, thus being suitable for application on flexible medical devices.