951 resultados para Reproducibility
Resumo:
Chromatography is a means of separating mixtures into their several components. TLC, mainly a liquid/solid process, is one of the separation techniques most often used. It is indispensable in laboratories dealing with natural products, organic and analytical chemistry. Commercial chromatography plates are offered at relatively high cost. In this work the construction of a hand-operated plate coater of stationary phases of low cost and good reproducibility is described to be used in teaching laboratories and research.
Resumo:
Soil organic matter (SOM) plays an important role in physical, chemical and biological properties of soil. Therefore, the amount of SOM is important for soil management for sustainable agriculture. The objective of this work was to evaluate the amount of SOM in oxisols by different methods and compare them, using principal component analysis, regarding their limitations. The methods used in this work were Walkley-Black, elemental analysis, total organic carbon (TOC) and thermogravimetry. According to our results, TOC and elemental analysis were the most satisfactory methods for carbon quantification, due to their better accuracy and reproducibility.
Resumo:
Työn tarkoituksena oli löytää kapillaarielektroforeesimenetelmä (CE), joka soveltuisi metallien neste-nesteuutossa käytettävien orgaanisten uuttofaasien koostumuksen analysointiin. Kapillaarielektroforeesissa käytetyn elektrolyyttiliuoksen analyytti-kohtaista optimointia ei tässä työssä tehty, vaan liikkeelle lähdettiin fenoleille tarkoitetulla menetelmällä. Tarkasteltavia uuttoreagenssiryhmiä olivat hydroksi-oksiimit sekä fosfiinihappo- ja fosforihappopohjaiset reagenssit. Tutkittavia kaupallisia laimentimia olivat Orfom SX 11 ja Shellsol D70. Lisäksi tutkittiin kahta modifiointiainetta, TOPOa (tri-n-oktyylifosfiinioksidi) ja TXIB:tä (2,2,4-trimetyyli-1,3-pentaanidiolidi-isobutyraatti). Työssä tavoiteltiin kapillaarielektroforeesin hyötyjä erityisesti hydrometallurgisessa teollisuudessa. Suurimpana hyötynä ennakoitiin mahdollisuus analysoida suuria molekyylejä, kuten uuttoreagenssi-metallikomplekseja, joita ei pystytä analysoimaan kaasukromatografilla (GC). Näytteet voidaan myös analysoida ilman hidasta ja usein ei-kvantitatiivista derivatisointia. Kirjallisuudesta ei löytynyt aiempia artikkeleita CE:n soveltamisesta kyseisille aiheille. Kapillaarielektroforeesianalyyseissa pystyttiin esimerkiksi havaitsemaan hydroksi-oksiimin kuparikompleksi orgaanisessa faasissa. Seulonta-ajoissa yleisenä ongelmana oli kuitenkin tulosten heikko toistettavuus. Kapillaari-elektro-foreesi-menetelmä tarjoaa selvästi mahdollisuuksia tulevaisuudessa, mutta vielä sillä ei päästy luotettavaan toistoon sähkökentän häiriöiden ja elektrolyyttiliuoksen riittämättömän optimoinnin vuoksi. Lisäksi teollisissa olosuhteissa käytetyille autenttisille hydroksioksiimi- ja fosfiinihapponäytteille tehtiin perinteisiä kaasukromatografia-analyysejä, joiden perusteella voitiin nähdä uuttofaasin koostumuksen muuttuneen prosessissa. Hapettuminen sekä eri hydrolyysireaktiot ovat tärkeimmät syyt reagenssien ja laimentimien muuttumiselle. Näitä hajoamistuotteita ei tässä työssä onnistuttu analysoimaan kapillaarielektroforeesilla.
Resumo:
Few articles deal with lead and strontium isotopic analysis of water samples. The aim of this study was to define the chemical procedures for Pb and Sr isotopic analyses of groundwater samples from an urban sedimentary aquifer. Thirty lead and fourteen strontium isotopic analyses were performed to test different analytical procedures. Pb and Sr isotopic ratios as well as Sr concentration did not vary using different chemical procedures. However, the Pb concentrations were very dependent on the different procedures. Therefore, the choice of the best analytical procedure was based on the Pb results, which indicated a higher reproducibility from samples that had been filtered and acidified before the evaporation, had their residues totally dissolved, and were purified by ion chromatography using the Biorad® column. Our results showed no changes in Pb ratios with the storage time.
Resumo:
In this work, a methodology for the characterization of sugar cane bagasse was validated. Bagasse pre-treated with steam in a 5000 L reactor at a pressure of 15.3 kgf/cm², during 7 min, was used to test the methodology. The methodology consisted of the hydrolysis of the material with H2SO4 at 72% v/v, for the quantification of carbohydrates, organic acid, furfural and hydroxymethylfurfural by HPLC; insoluble lignin and ash by gravimetry; and soluble lignin by spectrophotometry. Linearity, repeatability, reproducibility and accuracy of the results obtained in two Research Laboratories were determined, and were considered to be suitable for the validation of the methodology.
Resumo:
The evaluation of uncertainty associated with an analytic result is an essential part of the measurement process. Recently, several approaches to evaluate the uncertainty in measurement have been developed. Here, the gas chromatography assay uncertainty for natural gas is compared by some of these approaches: the guide to the expression of uncertainty in measurement (GUM) approach, top-down approach (reproducibility estimate from an inter-laboratory study), Barwick & Ellison (data from validation), study of variability and fuzzy approach. The comparison shows that GUM, Barwick & Ellison and fuzzy approaches lead to comparable uncertainty evaluations, which does not happen with the top-down approach and study of variability by the absence of data normality.
Resumo:
Intralaboratorial and interlaboratorial variabilities can be obtained by conducting an specially designed interlaboratory program. Using the analysis of variance technique one can calculate the r (repeatability) and R (reproducibility) indexes that can help participant laboratories to monitor their routine quality control procedures. An example is described using data obtained from an interlaboratory program where twelve laboratories determined total iron content in silicon metal sample by using flame atomic absorption spectrometry.
Resumo:
The aim of this work was the single-laboratory validation of a quantitative method for the determination of amoxicillin residues in support of cleaning control and validation. Linearity was demonstrated between 2.5 and 17.5 μg/mL, without matrix effects. Mean recoveries ranged from 84.00 to 103.74% and the relative standard deviation under repetitivity and within-reproducibility conditions were from 0.58 to 4.20% and from 0.79 to 4.39%, respectively. The theoretical limits of detection and quantification were 0.133 and 0.442 μg/mL, respectively. The studied method was suitable for cleaning control purpose within good manufacturing practices.
Resumo:
A derivative UV spectrophotometric method for determination of estradiol valerate in tablets was validated. The parameters specificity, linearity, precision, accuracy, limit of detection and limit of quantitation were studied according to validation guidelines. The first-order derivative spectra were obtained at N = 5, Δλ = 4.0 nm, and determinations were made at 270 nm. The method showed specificity and linearity in the concentration range of 0.20 to 0.40 mg mL-1. The intra and interday precision data demonstrated the method has good reproducibility. Accuracy was also evaluated and results were satisfactory. The proposed method was successfully applied to a pharmaceutical formulation.
Resumo:
The potentiality of the use of ultrasound radiation in association with a boron-doped diamond electrode was evaluated on the voltammetric determination of the pesticide carbaryl. Improvements in the sensitivity, limit of detection and reproducibility of the measurements were observed due to both, the enhancement of mass transport and the cleaning of the electrode surface provided by ultrasound. Satisfactory recovery levels for carbaryl in pure water (96-98%) and pineapple juice (89-92%) for quiescent and sonovoltammetric methodologies were obtained. These methodologies can be alternative tools for the analyses of pesticides in fruit samples, mainly the insonated condition that improve the analytical performance and dispense intermediary cleanings of the electrode surface.
Resumo:
A new electroanalytical method coupling TLC-DPV in solid state was developed for quantitative determination of phytoantioxidants with medicinal purpose, e.g. rosmarinic acid (RA) in samples of phytopharmaceuticals, e.g. rosemary (Rosmarinus officinalis L.). The method showed to be feasible, presenting linearity in concentrations ranging from 0.694 x 10-3 to 9.526 x 10-3 mol L-1 (r = 0.9945), good sensibility, selectivity, reproducibility, repeatability, agility and affordable cost. The concentrations of RA in different extracts of rosemary ranged from 0.05 to 0.52 (% w/w), presenting high recovery levels when compared to HPLC.
Resumo:
This review reports the use of solid amalgam electrodes in the electroanalytical determination of organic and inorganic compounds. The different types of amalgam electrodes are presented, and attention is paid to solid amalgam electrode, and here is presented details about the pre-treatment for activation and renovation and also possible modifications in its surface. The wide potential range, higher signal-to-noise ratio, mechanical stability enabling their application in flowing systems, and principally their resistance toward passivation, indicate that the solid amalgam electrodes are environmentally friendly alternatives to mercury electrodes, without loss in the sensitivity and reproducibility in voltammetric responses.
Resumo:
Infrared spectroscopy is a versatile technique used for qualitative and quantitative determination of all types of molecular species. As far as analysis of confined or flowing gases is concerned, different types of cell can be found in the market, but they are often very expensive. This study describes the construction of a very efficient gas cell with good reproducibility for qualitative infrared analysis of confined or flowing gases, using easily available and low-cost materials.
Resumo:
A validation study of an UV spectrophotometric method was conducted for quantitative analysis of benznidazol (BZN) in a lipid. The analytical determinations were performed at 315 nm at 25 ºC. The emulsion components did not interfere on drug analyses, demonstrating the specificity of the methodology. A good linearity (r = 0.99995) and precision (RSD < 5.0%) for intra and inter-day studies, including the reproducibility test were observed. The accuracy ranged of 102.1 + 2.8 e 103.8 + 1.7%. The statistical analysis demonstrates a linear, precise, accurate and robust method for BZN quantification from the lipid emulsion system.
Resumo:
This paper presents the electrolyte influence on deposition and dissolution processes of Cu nanoparticles on boron doped diamond electrodes (BDD). Morphological, structural and electrochemical analysis showed BDD films with good reproducibility, quality and reversible in a specific redox system. Electrodeposition of Cu nanoparticles on DDB electrodes in three different solutions was influenced by pH and ionic strength of the electrolytic medium. Analyzing the process as function of the scan rate, it was verified a better efficiency in 0,5 mol L-1 Na2SO4 solution. Under the influence of the pH and ionic strength, Cu nanoparticles on DDB may be obtained with different morphologies and it was important for defining the desired properties.