932 resultados para Heat pump, Solar Energy, Ambient Energy, Evaporator Collector, Collector Efficiency
Resumo:
El objetivo principal del presente Proyecto Fin de Carrera es el de dotar a la Escuela Universitaria de Ingenieros Tcnicos de Telecomunicacin Universidad Politcnica de Madrid (EUITT-UPM) de un banco de medida donde poder caracterizar los mdulos fotovoltaicos en condiciones reales de operacin. Es necesario comprobar el funcionamiento de los mdulos para asegurarse de que est acorde a lo indicado en las especificaciones anunciadas por los fabricantes. A lo largo del texto daremos una introduccin al concepto de energa solar fotovoltaica y una descripcin de los sistemas tanto aislados como los conectados a la red elctrica de distribucin. Hablaremos sobre el fenmeno fotovoltaico y describiremos los mdulos fotovoltaicos para ver las partes de las que est compuesto un mdulo. Finalmente nos centraremos en el banco de ensayo y acabaremos explicando el caso prctico realizado en la EUITT. A travs de la medida de la curva I-V del mdulo fotovoltaico en condiciones reales de operacin y la extrapolacin de los resultados obtenidos a las Condiciones Estndar de Medida (CEM) comprobaremos lo que se ajustan los valores dados por los fabricantes de los mdulos solares. ABSTRACT. The main aim of this project is to provide the EUITT-UPM a measure workbench to characterize photovoltaic (PV) modules in real test conditions (RTC). It is necessary to check the PV modules operations to assure that its characteristics are close to the ones given by the manufacturers. I will introduce the concept of photovoltaic solar energy and describe remote systems as well as network-connected systems. I will talk about the photovoltaic phenomenon and describe the PV modules in order to know the parts making up a module. Finally, I shall describe the measure workbench explaining the practical case carried out at the university. By measuring the I-V curve of PV modules in real test conditions and the later extrapolation of the results to the standard test conditions (STC), manufacturers data can be compared to the data obtained within this study.
Resumo:
The solar irradiation that a crop receives is directly related to the physical and biological processes that affect the crop. However, the assessment of solar irradiation poses certain problems when it must be measured through fruit inside the canopy of a tree. In such cases, it is necessary to check many test points, which usually requires an expensive data acquisition system. The use of conventional irradiance sensors increases the cost of the experiment, making them unsuitable. Nevertheless, it is still possible to perform a precise irradiance test with a reduced price by using low-cost sensors based on the photovoltaic effect. The aim of this work is to develop a low-cost sensor that permits the measurement of the irradiance inside the tree canopy. Two different technologies of solar cells were analyzed for their use in the measurement of solar irradiation levels inside tree canopies. Two data acquisition system setups were also tested and compared. Experiments were performed in Ademuz (Valencia, Spain) in September 2011 and September 2012 to check the validity of low-cost sensors based on solar cells and their associated data acquisition systems. The observed difference between solar irradiation at high and low positions was of 18.5% 2.58% at a 95% confidence interval. Large differences were observed between the operations of the two tested sensors. In the case of a-Si cells based mini-modules, an effect of partial shadowing was detected due to the larger size of the devices, the use of individual c-Si cells is recommended over a-Si cells based mini-modules.
Resumo:
This paper describes the preliminary results of an intercomparison of spectroradiometers for global (GNI) and direct normal incidence (DNI) irradiance in the visible (VIS) and near infrared (NIR) spectral regions together with an assessment of the impact these results may have on the calibration of triple-junction photovoltaic devices and on the relevant spectral mismatch calculation. The intercomparison was conducted by six European scientific laboratories and a Japanese industrial partner. Seven institutions and seven spectroradiometer systems, representing different technologies and manufacturers were involved, representing a good cross section of the todays available instrumentation for solar spectrum measurements.
Resumo:
This paper will present an open-source simulation tool, which is being developed in the frame of an European research project1. The tool, whose final version will be freely available through a website, allows the modelling and the design of different types of grid-connected PV systems, such as large grid-connected plants and building-integrated installations. The tool is based on previous software developed by the IES-UPM2, whose models and energy losses scenarios have been validated in the commissioning of PV projects3 carried out in Spain, Portugal, France and Italy, whose aggregated capacity is nearly 300MW. This link between design and commissioning is one of the key points of tool presented here, which is not usually addressed by present commercial software. The tool provides, among other simulation results, the energy yield, the analysis and breakdown of energy losses, and the estimations of financial returns adapted to the legal and financial frameworks of each European country. Besides, educational facilities will be developed and integrated in the tool, not only devoted to learn how to use this software, but also to train the users on the best design PV systems practices. The tool will also include the recommendation of several PV community experts, which have been invited to identify present necessities in the field of PV systems simulation. For example, the possibility of using meteorological forecasts as input data, or modelling the integration of large energy storage systems, such as vanadium redox or lithium-ion batteries. Finally, it is worth mentioning that during the verification and testing stages of this software development, it will be also open to the suggestions received from the different actors of the PV community, such as promoters, installers, consultants, etc.
Resumo:
The installers and owners show a growing interest in the follow-up of the performance of their photovoltaic (PV) systems. The owners are requesting reliable sources of information to ensure that their system is functioning properly, and the installers are actively looking for efficient ways of providing them the most useful possible information from the data available. Policy makers are becoming increasingly interested in the knowledge of the real performance of PV systems and the most frequent sources of problems that they suffer to be able to target the identified challenges properly. The scientific and industrial PV community is also requiring an access to massive operational data to pursue the technological improvements further.
Resumo:
This paper presents the measurement of the I-V curve of an 800 kW PV generator by means of an own-made capacitive load. Along the lines of some previous works, it is shown that an I-V curve analysis can also be applied to big PV generators and that, when measuring the operating conditions with reference modules and taking some precautions (especially regarding the operating cell temperature), it is still a useful tool for characterizing them and therefore can be incorporated into maintenance procedures. As far as we know, this is the largest I-V curve measured so far.
Resumo:
The intermediate band solar cell (IBSC), the multiple exciton generation solar cell (MEGSC) and the hot carrier solar cell (HCSC) are three novel concepts in photovoltaics which aim to achieve high efficiency devices. In this paper we assess to what extent their physical principles of operation have been experimentally verified. It is found that there is experimental evidence supporting the underlying theory for all three.
Resumo:
Starting on June 2011, NGCPV is the first project funded jointly between the European Commission (EC) and the New Energy and Industrial Technology Development Organization (NEDO) of Japan to research on new generation concentration photovoltaics (CPV). The Project, through a collaborative research between seven European and nine Japanese leading research centers in the field of CPV, aims at lowering the cost of the CPVproduced photovoltaic kWh down to 5 ?cents. The main objective of the project is to improve the present concentrator cell, module and system efficiency, as well as developing advanced characterization tools for CPV components and systems. As particular targets, the project aims at achieving a cell efficiency of at least 45% and a CPV module with an efficiency greater than 35%. This paper describes the R&D activities that are being carried out within the NGCPV project and summarizes some of the most relevant results that have already been attained, for instance: the manufacturing of a 44.4% world record efficiency triple junction solar cell (by Sharp Corp.) and the installation of a 50 kWp experimental CPV plant in Spain, which will be used to obtain accurate forecasts of the energy produced at system level.
Resumo:
The degradation observed on a 7-kWp Si-x photovoltaic array after 17years of exposure on the roof of the Solar Energy Institute of the Polytechnic University of Madrid is presented. The mean peak power degradation has been 9% over this time, or an equivalent to 0.53% per year, whereas peak power standard deviation has remained constant. The main visual defects are backsheet delamination at the polyester/polyvinyl fluoride outer interface and cracks in the terminal boxes and at the joint between the frame and the laminate. Insulation resistance complies well with the requirements of the International Electrotechnical Commission 61215 tests.
Resumo:
The PVCROPS project (PhotoVolta ic Cost rduction, Reliability, Operational performance, Prediction and Simulation), cofinanced by European Commission in the frame of Seventh Framework Programme, has compiled in the Good and bad practices: Manual to improve the quality and reduce the cost of PV systems a collection of good and bad practices in actual PV plants . All the situations it collects represent the state-of-the-art of existing PV installations all around Europe. They show how the different parts of an installation can be implem ented properly or not. The aim of this manual is to represent a reference text which can help any PV actor (installers, electricians, maintenance operators, owners, etc.) not only to check and improve an already existing installation but will also, and mainly, avoid the previously known bad practices for the construction of a new PV installation. Thus, solving a priori the known errors, new PV installations will be more reliable, efficient and cost-effective and can recover the initial investment in a shorter time. The manual is going to be free available in the PVCROPS website in several languages.
Resumo:
Wide experimental evidence of the phosphorus diffusion gettering beneficial effect on solar grade silicon is found by measuring electron effective lifetime and interstitial iron concentration in as-grown and post processed samples from two ingots of upgraded metallurgical grade silicon produced by Ferrosolar. Results after two different P-diffusion processes are compared: P emitter diffusion at 850C followed by fast cool-down (called standard process) or followed by slow cool-down (called extended process). It is shown that final lifetimes of this low cost material are in the range of those obtained with conventional material. The extended process can be beneficial for wafers with specific initial distribution and concentration of iron, e.g. materials with high concentration of big Fe precipitates, while for other cases the standard process is enough efficient. An analysis based on the comparison of measured lifetime and dissolved iron concentration with theoretical calculations helps to infer the initial iron distribution and concentration, and according to that, choose the more effective type of gettering.
Resumo:
This paper presents different test alternatives which can be used on-site in a PV installation to detect potential induced degradation (PID) in modules. The testing procedures proposed are: thermal imaging; electroluminescence imaging; open circuit voltage measurements; operating voltage measurements; IV curve measurements; and dark IV curve measurements. Advantages and disadvantages of each test are reported.
Resumo:
Several dielectric fluids that might be used for immersing optics are analyzed in this paper. Their transmittances, both before and after an accelerated exposure to ultraviolet (UV) radiation equivalent to several years under real sun, are presented. In addition, the photocurrent losses caused by the decrease in transmittance experienced by each fluid are estimated for current III?V multijunction (MJ) solar cells. The most stable fluids were found to be paraffin and silicone oils whose transmittances remained practically unaltered after a UV dosage equivalent to 3 years of AM1.5D radiation.
Resumo:
Defect interaction can take place in CdTe under Te and Bi rich conditions. We demonstrate in this work through first principles calculations, that this phenomenon allows a Jahn Teller distortion to form an isolated half-filled intermediate band in the host semiconductor band-gap. This delocalized energy band supports the experimental deep level reported in the host band-gap of CdTe at a low bismuth concentration. Furthermore, the calculated optical absorption of CdTe:Bi in this work shows a significant subband-gap absorption that also supports the enhancement of the optical absorption found in the previous experimental results.
Resumo:
The hot-spot phenomenon is a relatively frequent problem in current photovoltaic generators. It entails both a risk for the photovoltaic module's lifetime and a decrease in its operational efficiency. Nevertheless, there is still a lack of widely accepted procedures for dealing with them in practice. This paper presents the IES UPM observations on 200 affected modules. Visual and infrared inspection, electroluminescence, peak power and operating voltage tests have been accomplished. Hot-spot observation procedures and well defined acceptance and rejection criteria are proposed, addressing both the lifetime and the operational efficiency of the modules. The operating voltage has come out as the best parameter to control effective efficiency losses for the affected modules. This procedure is oriented to its possible application in contractual frameworks.