A 800 kW I-V curve


Autoria(s): Moreton Villagra, Rodrigo; Martinez Moreno, Francisco; Lorenzo Pigueiras, Eduardo; Muñoz, Javier; Narvarte Fernandez, Luis
Data(s)

2013

Resumo

This paper presents the measurement of the I-V curve of an 800 kW PV generator by means of an own-made capacitive load. Along the lines of some previous works, it is shown that an I-V curve analysis can also be applied to big PV generators and that, when measuring the operating conditions with reference modules and taking some precautions (especially regarding the operating cell temperature), it is still a useful tool for characterizing them and therefore can be incorporated into maintenance procedures. As far as we know, this is the largest I-V curve measured so far.

Formato

application/pdf

Identificador

http://oa.upm.es/25782/

Idioma(s)

eng

Relação

http://oa.upm.es/25782/1/INVE_MEM_2013_160993.pdf

info:eu-repo/semantics/altIdentifier/doi/null

Direitos

http://creativecommons.org/licenses/by-nc-nd/3.0/es/

info:eu-repo/semantics/openAccess

Fonte

28th European PV Solar Energy Conference and Exhibition | 28th European PV Solar Energy Conference and Exhibition | 30/09/2013 - 04/10/2013 | Paris, France

Palavras-Chave #Telecomunicaciones #Electrónica #Física
Tipo

info:eu-repo/semantics/conferenceObject

Ponencia en Congreso o Jornada

PeerReviewed